Sure Cross Wireless Q45VA Vibration and  
Temperature Sensor  
Datasheet  
®
The Wireless Q45VA All-in-One Sensor Node combines Banner's VT1 Vibration and Temperature Sensor with the Sure Cross  
Q45VT Wireless Sensor Node. The Q45VA is a compact, industrial, battery-powered device that wirelessly communicates with any  
Sure Cross Performance Gateway on a variety of machines to analyze vibration and temperature data to identify and predict  
failures in rotating machinery.  
Benefits  
Delivers pre-processed high accuracy vibration values for monitoring rotating equipment such as:  
Motors  
Pumps  
Rotary Compressors  
Exhaust or HVAC fan motors  
Spindles  
Easy-to-use rugged device that can be easily mounted to equipment  
Use with the DXM Wireless Controller to track and trend vibration and temperature characteristics in real time to predict  
need for maintenance, predict potential component failure and avoid process downtime.  
Battery powered for “peel and stick” functionality with 2+ years of battery life  
Detects vibration characteristics on 2 axis (radial and axial) such as RMS Velocity, High Frequency Acceleration, Peak  
Acceleration, Peak Velocity Component Frequency, etc  
Achieves vibration accuracy of 1ꢀ0 RMS velocity (inꢁsec)  
Eliminate control wires—The Sure Cross wireless system is a radio frequency network with integrated IꢁO that removes the  
need for power and control wires  
Reduce complexity—Machine or process reconfiguration made easier; great for retrofit applications  
Deploy easily—Simplify installation on existing equipment enables deployment in remote and hard-to-access locations  
where implementing a wired solution would be difficult, impractical, or not cost-effective  
Transmit power levels of 25ꢀ mW or 1 Watt for 9ꢀꢀ MHz models and 65 mW for 2.4  
GHz models are user-selectable  
DIP switches for user configuration of sample time and vibration characteristics  
Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data  
delivery within the unlicensed Industrial, Scientific, and Medical (ISM) band  
Transceivers provide bidirectional communication between the Gateway and Node,  
including fully acknowledged data transmission  
Diagnostics allow user-defined output settings in the unlikely event of lost RF signal  
WARNING:  
Do not use this device for personnel protection  
Using this device for personnel protection could result in serious injury or death.  
This device does not include the self-checking redundant circuitry necessary to allow its use in  
personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-  
energized (off) output condition.  
Models  
Model  
Radio Frequency  
Inputs and Outputs  
Vibration and temperature detection  
DX8ꢀN2Q45VA  
DX8ꢀN9Q45VA  
2.4 GHz ISM Band  
9ꢀꢀ MHz ISM Band  
1
1
Only models produced after date code 1925x include the temperature sensor.  
Original Document  
2ꢀ57ꢀ4 Rev. C  
1ꢀ June 2ꢀ19  
205704  
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
®
Exporting Sure Cross Radios. It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Customers who want to re-export this product  
to a country other than that to which it was sold must ensure the device is approved in the destination country. The Sure Cross wireless products were certified for use in these countries  
using the antenna that ships with the product. When using other antennas, verify you are not exceeding the transmit power levels allowed by local governing agencies. This device has  
been designed to operate with the antennas listed on Banner Engineering’s website and having a maximum gain of 9 dBm. Antennas not included in this list or having a gain greater that 9  
dBm are strictly prohibited for use with this device. The required antenna impedance is 5ꢀ ohms. To reduce potential radio interference to other users, the antenna type and its gain  
should be so chosen such that the equivalent isotropically radiated power (EIRP) is not more than that permitted for successful communication. Consult with Banner Engineering Corp. if  
the destination country is not on this list.  
Storage Mode  
While in storage mode, the Q45VA's radio does not operate. The Q45VA ships from the factory in storage mode to conserve the  
battery. To wake the device, press and hold the binding button (inside the housing on the radio board) for five seconds. To put any  
Q45VA into storage mode, press and hold the binding button for five seconds. The Q45VA is in storage mode when the LEDs stop  
blinking.  
General Operation  
For the first 15 minutes after power up, the Node samples the sensor every two seconds (fast sample mode). After 15 minutes, the  
Node defaults to 5 minute sample intervals. Activate fast sample mode by single clicking the button (the amber LED is solid).  
ISO 1ꢀ816 provides guidance for evaluating vibration velocity severity motors, pumps, fans, compressors, gear boxes, blowers,  
dryers, presses, and other machines that operate in the 1ꢀ to 1ꢀꢀꢀ Hz frequency range.  
Machine  
in/s  
Class I  
Small Machines  
Class II  
Medium Machines  
Class III  
Large Rigid Foundation  
Class IV  
Large Soft Foundation  
mm/s  
0.28  
0.45  
0.71  
1.12  
1.80  
2.80  
4.50  
7.10  
11.2  
18.0  
28.0  
45.9  
0.01  
0.02  
0.03  
0.04  
0.07  
0.11  
0.18  
0.28  
0.44  
0.70  
1.10  
1.77  
good  
satisfactory  
unsatisfactory  
unacceptable  
Figure 1. Vibration Severity per ISO 1ꢀ816  
Button and LEDs  
1
Button  
2
3
4
5
Red LED (flashing) indicates a radio link error with the Gateway.  
Green LED (flashing) indicates a good radio link with the Gateway.  
Amber LED is not used.  
3
2
1
5
4
DIP Switches  
2
www.bannerengineering.com - Tel: + 1 888 373 6767  
PꢁN 2ꢀ57ꢀ4 Rev. C  
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
Installing the Q45  
The vibration sensors have an X and Z axis indication on the face of the sensor.  
Install the X axis in line with the shaft of the motor or axially.  
Install the Z axis to go into or through the motor or radial.  
For the best results, install the sensor as close to the motor bearing as possible. If this is  
not possible, install the sensor on a surface that is in rigid connection with vibration  
characteristics of the motor. Using a cover shroud or other flexible mounting location may  
result in reduced accuracy or reduced ability to detect certain vibration characteristics.  
z-axis  
vibration  
sensitivity  
The Q45VA body can be affixed to the motor using Loctite 33ꢀ and 7387 Activator or  
similar adhesive. For information about optional brackets, see Brackets (p. 9).  
x-axis  
vibration sensitivity  
Configuration Instructions  
Bind to the Gateway and Assign the Node Address  
Before beginning the binding procedure, apply power to all the devices. Separate the devices by two meters when running binding  
procedure. Put only one Gateway into binding at a time to prevent binding to the wrong Gateway.  
Figure 2. Buttons on a housed Gateway  
1. Enter binding mode on the Gateway.  
For housed DX8ꢀ Gateways, triple-click button 2 on the Gateway. Both LEDs flash red.  
For board-level DX8ꢀ Gateways, triple-click the binding button on the Gateway. The green and red LED flashes.  
2. Assign the Q45VA a Node address using the Gateway's rotary dials. Use the left rotary dial for the left digit and the right  
rotary dial for the right digit. For example, to assign your Q45VA to Node 1ꢀ, set the Gateway's left dial to 1 and the right  
dial to ꢀ. Valid Node addresses are ꢀ1 through 47.  
3. Loosen the clamp plate on the top of the Q45VA and lift the cover.  
4. Enter binding mode on the Q45VA by triple-clicking the Q45VA's binding button.  
The red and green LEDs flash alternately and the sensor searches for a Gateway in binding mode. After the Q45VA is  
bound, the LEDs stay solid momentarily, then they flash together four times. The Q45VA exits binding mode.  
5. Label the sensor with the Q45VA's Node address number for future reference.  
6. Repeat steps 2 through 5 for as many Q45VA as are needed for your network.  
7. After binding all Q45VA, exit binding mode on the Gateway.  
For housed DX8ꢀ Gateways, double-click button 2 on the Gateway.  
For board-level DX8ꢀ Gateways, double-click the binding button on the Gateway.  
For Gateways with single-line LCDs, after binding your Q45VA to the Gateway, make note of the binding code displayed under the  
Gateway's *DVCFG menu, XADR submenu on the LCD. Knowing the binding code prevents having to re-bind all Q45VAs if your  
Gateway is ever replaced.  
Bind to a DXM Gateway and Assign the Node Address  
Before beginning the binding procedure, apply power to all the devices. Separate radios by two meters when running binding  
procedure. Put only one DXM Gateway into binding at a time to prevent binding to the wrong Gateway.  
PꢁN 2ꢀ57ꢀ4 Rev. C  
www.bannerengineering.com - Tel: + 1 888 373 6767  
3
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
1. On the DXM radio using the arrow keys select the ISM Radio menu on the LCD and click ENTER.  
2. Highlight the Binding menu and click ENTER.  
3. Use the arrow keys to select the Node address to bind the Q45VA to.  
4. Loosen the clamp plate on the top of the Q45VA and lift the cover.  
5. Enter binding mode on the Q45VA by triple-clicking the powerꢁbinding button.  
The red and green LEDs flash alternately and the sensor searches for a Gateway in binding mode. After the Q45VA binds,  
the LEDs stay solid momentarily, then they flash together four times. The Q45VA exits binding mode.  
6. Label the sensor with the Q45VA's Node address number for future reference.  
7. Click BACK on DXM to exit binding for that specific Node address.  
8. Repeat steps 3 through 7 changing the Node address for as many Q45VAs as are needed for your network.  
9. Click BACK on DXM until back to the main menu when finished binding.  
DIP Switches  
After making any changes to any DIP switch position, reboot the Q45VA by triple-clicking the button, waiting a second, then  
double-clicking the button.  
The DIP switches are in the OFF position. To turn a DIP switch on, push the switch toward the battery pack. DIP switches one  
through four are numbered from left to right.  
DIP Switches  
Description  
1
2
3
4
5
6
7
8
Transmit power: 1 Watt  
OFF*  
ON  
Transmitt power: 25ꢀ mW (compatible with 15ꢀ mW radios)  
2
Default IꢁO Configuration  
OFF*  
OFF  
OFF  
OFF  
ON  
OFF*  
OFF  
ON  
OFF*  
ON  
IꢁO Configuration 1  
IꢁO Configuration 2  
OFF  
ON  
IꢁO Configuration 3  
ON  
IꢁO Configuration 4  
OFF  
OFF  
ON  
OFF  
ON  
IꢁO Configuration 5  
ON  
Reserved  
ON  
OFF  
ON  
Reserved  
ON  
ON  
SampleꢁReport Rate: User configured (5 minutes by default)  
SampleꢁReport Rate: 15ꢀ seconds  
SampleꢁReport Rate: 6ꢀ seconds  
Reserved  
OFF*  
OFF  
ON  
OFF*  
ON  
OFF  
ON  
ON  
English Units (inꢁs and °F)  
Metric Units (mmꢁs and °C)  
Reserved  
OFF*  
ON  
OFF*  
* Default position  
IꢁO Configurations (Set by DIP Switches 2, 3, and 4)  
IꢁO Configuration 1 IꢁO Configuration 2 IꢁO Configuration 3 IꢁO Configuration 4  
High-Frequency RMS RMS Velocity (inꢁ  
Input  
Register  
Default IꢁO  
IꢁO Configuration 5  
Full Bandwidth RMS  
Acceleration (G)  
1
2
RMS Velocity (inꢁsec) RMS Velocity (inꢁsec)  
RMS Velocity (inꢁsec)  
Acceleration (G)  
sec)  
Z-Axis  
Peak Velocity  
Peak Acceleration (G) Component  
Frequency (Hz)  
High-Frequency RMS  
Peak Acceleration (G)  
Acceleration (G)  
Full Bandwidth Peak  
Acceleration (G)  
Full Bandwidth RMS  
Acceleration (G)  
3
4
-
-
Temperature (°F)  
Reserved  
Temperature (°F)  
Reserved  
Temperature (°F)  
Reserved  
Temperature (°F)  
Reserved  
Temperature (°F)  
Reserved  
Temperature (°F)  
Reserved  
High-Frequency RMS RMS Velocity (inꢁ  
Acceleration (G) sec)  
Full Bandwidth RMS  
Acceleration (G)  
5
X-Axis RMS Velocity (inꢁsec) RMS Velocity (inꢁsec)  
RMS Velocity (inꢁsec)  
2
User configurable if switch 7 is OFF; for input serial addresses, see Modbus Registers and IꢁO Serial Addresses (p. 5)  
4
www.bannerengineering.com - Tel: + 1 888 373 6767  
PꢁN 2ꢀ57ꢀ4 Rev. C  
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
IꢁO Configurations (Set by DIP Switches 2, 3, and 4)  
Input  
Register  
Default IꢁO  
IꢁO Configuration 1  
IꢁO Configuration 2  
IꢁO Configuration 3 IꢁO Configuration 4  
IꢁO Configuration 5  
Peak Velocity  
Peak Acceleration (G) Component  
Frequency (Hz)  
High-Frequency RMS  
Acceleration (G)  
Full Bandwidth Peak  
Acceleration (G)  
Full Bandwidth RMS  
Acceleration (G)  
6
Peak Acceleration (G)  
If DIP switch 7 is on, all inꢁs units change to mmꢁs. DIP switch 7 will only switch units with DIP switch IꢁO configurations, not with  
any user configuration.  
Configure the Q45 Using the User Configuration Software  
The User Configuration Software offers an easy way to change sensor settings, show sensor data from different sensors, and  
retrieve data from the Gateway radio. The software runs on any Windows computer and uses an adapter cable to connect the  
Gateway to your computer.  
Download the most recent version of the software from Banner Engineering's website: www.bannerengineering.comꢁwireless.  
1. Go to the Configuration > Device Configuration screen.  
2. On the top of the screen, select Nodes Currently in the System from the drop-down list and click Get devices in system.  
All Nodes bound to the Gateway connected to the computer display.  
3. Click the arrow next to the Nodes to display the parameters specific to that Node.  
In this example, the parameters for Node 1 are shown.  
4. Under the Node 1 IꢁO points section, click GET IꢁO Points.  
All IꢁO types for this Node are loaded onto the screen.  
5. To view the parameters for an IꢁO point, click the arrow next to that IꢁO point.  
In this example, the parameters for IꢁO point 1 are shown.  
6. To set the Serial address, go to the Serial options section of the IꢁO point's parameters and enter the value.  
In this example, the Serial address is set to 16 for output Z-Axis RMS Velocity (inꢁsec).  
7. After making changes to the IꢁO point parameters, click SEND to send the changes to the network.  
8. Repeat steps 5 and 8 for each input to manually change the configuration of the vibration parameters by changing the  
serial address.  
For more information on using the User Configuration Software, refer to the instruction manual (pꢁn 14ꢀ628).  
Modbus Registers and I/O Serial Addresses  
IꢁO Serial Addresses  
IꢁO Range  
Holding Register Representation  
Serial  
Address  
Output Type  
Min  
Max  
6.5535  
Min (Dec)  
Max (Dec)  
65535  
1, 5  
16  
Z-Axis RMS Velocity (inꢁsec)  
PꢁN 2ꢀ57ꢀ4 Rev. C  
www.bannerengineering.com - Tel: + 1 888 373 6767  
5
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
IꢁO Serial Addresses  
IꢁO Range  
Holding Register Representation  
Serial  
Address  
Output Type  
Min  
Max  
Min (Dec)  
Max (Dec)  
2, 5  
25  
-
Z-Axis High-Frequency RMS Acceleration  
Reserved  
65.535  
-
65535  
-
-
-
1, 5  
64  
73  
2ꢀ  
68  
18  
66  
19  
67  
24  
72  
37  
69  
17  
23  
65  
71  
22  
7ꢀ  
27  
75  
28  
76  
192  
193  
X-Axis RMS Velocity (inꢁsec)  
6.5535  
65.535  
65.535  
65.535  
6553.5  
6553.5  
65.535  
65.535  
65.535  
65.535  
65.535  
65.535  
6.5535  
65.535  
6.5535  
65.535  
65.535  
65.535  
65.535  
65.535  
65.535  
65.535  
1638.4  
1638.4  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
65535  
32767  
32767  
2, 5  
X-Axis High-Frequency RMS Acceleration (G)  
2, 6  
Z-Axis Peak Acceleration (G)  
2, 6  
X-Axis Peak Acceleration (G)  
4, 5  
Z-Axis Peak Velocity Component Frequency (Hz)  
X-Axis Peak Velocity Component Frequency (Hz)  
4, 5  
2, 5  
Z-Axis RMS Acceleration (G)  
2, 5  
X-Axis RMS Acceleration (G)  
2, 6  
Z-Axis Kurtosis  
2, 6  
X-Axis Kurtosis  
2, 6  
Z-Axis Crest Factor  
2, 6  
X-Axis Crest Factor  
1, 5  
Z-Axis Peak Velocity (inꢁsec)  
1, 5  
Z-Axis Peak Velocity (mmꢁsec)  
1, 5  
X-Axis Peak Velocity (inꢁsec)  
1, 5  
X-Axis Peak Velocity (mmꢁsec)  
2, 5  
Z-Axis RMS Velocity (mmꢁsec)  
2, 5  
X-Axis RMS Velocity (mmꢁsec)  
2, 6  
Full Bandwidth RMS Acceleration Z-Axis (G)  
2, 6  
Full Bandwidth RMS Acceleration X-Axis (G)  
2, 7  
Full Bandwidth Peak Acceleration Z-Axis (G)  
2, 7  
Full Bandwidth Peak Acceleration X-Axis (G)  
3
Temperature (°C)  
–1638.4  
–1638.4  
–32768  
–32768  
3
Temperature (°F)  
1 Value = Register value ÷ 1ꢀꢀꢀꢀ  
2 Value = Register value ÷ 1ꢀꢀꢀ  
3 Value = Register value ÷ 2ꢀ  
4 Value = Register value ÷ 1ꢀ  
5 Measurement bandwidth = 1ꢀ Hz to 1 kHz  
6 Measurement bandwidth = 1 kHz to 4 kHz  
7 Measurement Bandwidth = 1ꢀ Hz to 4 kHz  
IꢁO #  
Modbus Holding Register  
IꢁO Type  
IꢁO Range  
Holding Register  
Representation  
Gateway  
Any Node  
Min.  
Max.  
Min.  
Max.  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1 + (Node# × 16)  
2 + (Node# × 16)  
3 + (Node# × 16)  
4 + (Node# × 16)  
5 + (Node# × 16)  
6 + (Node# × 16)  
7 + (Node# × 16)  
8 + (Node# × 16)  
...  
Sensor Input Register 1  
Sensor Input Register 2  
Sensor Input Register 3  
Sensor Input Register 4  
Sensor Input Register 5  
Sensor Input Register 6  
Reserved  
Device Message  
15  
16  
15  
16  
15 + (Node# × 16)  
16 + (Node# × 16)  
Control Message  
Reserved  
6
www.bannerengineering.com - Tel: + 1 888 373 6767  
PꢁN 2ꢀ57ꢀ4 Rev. C  
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
By default, data is supplied to the Node every five minutes, unless the Node requests the data sooner. The default configuration is  
shown and all optional outputs types are listed. Use the User Configuration Software to adjust the Sensor Register output type. For  
more information, see Configure the Q45 Using the User Configuration Software (p. 5).  
Temperature values outside the operating range of the device are forced to the maximum or minimum values.  
Replace or Install the Batteries  
To replace the lithium "AA" cell battery, follow these steps. As with all batteries, these are a fire, explosion, and severe burn hazard.  
Do not burn or expose them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to water. Properly  
dispose of used batteries according to local regulations by taking it to a hazardous waste collection site, an e-waste disposal  
center, or other facility qualified to accept lithium batteries.  
1. Lift the plastic cover.  
2. Slide the board containing the batteries out of the Q45VA housing.  
3. Remove the discharged batteries and replace with new batteries. Use two 3.6 V AA  
lithium batteries, such as Xeno's XL-6ꢀF or equivalent.  
4. Verify the battery’s positive and negative terminals align to the positive and negative  
terminals of the battery holder mounted within the case. Caution: There is a risk of  
explosion if the battery is replaced incorrectly.  
5. Slide the board containing the new batteries back into the Q45VA housing.  
The replacement battery model number is BWA-BATT-ꢀꢀ6. For pricing and availability,  
contact Banner Engineering.  
Specifications  
Performance Radio with Internal Antenna Specifications  
Radio Range3  
9ꢀꢀ MHz Compliance (1 Watt)  
9ꢀꢀ MHz, 1 Watt (Internal antenna): Up to 3.2 km (2 miles) with line of sight  
2.4 GHz, 65 mW (Internal antenna): Up to 1ꢀꢀꢀ m (328ꢀ ft) with line of sight  
FCC ID UE3RM18ꢀ9: FCC Part 15, Subpart C, 15.247  
IC: 7ꢀ44A-RM18ꢀ9  
Antenna Minimum Separation Distance  
9ꢀꢀ MHz, 15ꢀ mW and 25ꢀ mW: 2 m (6 ft)  
9ꢀꢀ MHz, 1 Watt: 4.57 m (15 ft)  
2.4 GHz Compliance  
FCC ID UE3ꢀꢀDX8ꢀ-24ꢀꢀ: FCC Part 15, Subpart C, 15.247  
RED Directive 2ꢀ14ꢁ53ꢁEU  
IC: 7ꢀ44A-DX8ꢀ24  
2.4 GHz, 65 mW: ꢀ.3 m (1 ft)  
Radio Transmit Power  
Link Timeout  
9ꢀꢀ MHz, 1 Watt: 3ꢀ dBm (1 W) conducted (up to 36 dBm EIRP)  
2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 2ꢀ dBm  
(1ꢀꢀ mW) EIRP  
Gateway: Configurable via User Configuration Tool (UCT) software  
Node: Defined by Gateway  
Radiated Immunity HF  
1ꢀ Vꢁm (EN 61ꢀꢀꢀ-4-3)  
Spread Spectrum Technology  
FHSS (Frequency Hopping Spread Spectrum)  
Q45VA Sensor Specifications  
Default Sensing Interval  
5 minutes  
Vibration Sensor  
Measuring Range: ꢀ to 46 mmꢁsec or ꢀ to 1.8 inꢁsec RMS  
Frequency Range: 1ꢀ Hz to 4 kHz  
Accuracy: 1ꢀ0 at 25 °C  
Sampling Frequency: 2ꢀ kHz (default)  
Record Length: 8192 points (default)  
Sample Duration: ꢀ.4 s (default)  
Indicators  
Red and green LEDs (radio function)  
Construction  
Molded reinforced thermoplastic polyester housing, oring-sealed  
®
transparent Lexan cover, molded acrylic lenses, and stainless steel  
Temperature Sensor  
Measuring Range: –4ꢀ °C to +1ꢀ5 °C (–4ꢀ °F to +221 °F)  
hardware. Designed to withstand 12ꢀꢀ psi washdown.  
Shock  
4ꢀꢀG  
Operating Conditions  
Ambient temperature: –4ꢀ °C to +7ꢀ °C (–4ꢀ °F to +158 °F)  
Contact temperature: –4ꢀ °C to +1ꢀ5 °C (–4ꢀ °F to +221 °F)  
9ꢀ0 at +5ꢀ °C maximum relative humidity (non-condensing)  
Environmental Rating  
NEMA 6P, IEC IP67  
Typical Battery Life  
See chart.  
3
Range depends on the environment and decreases significantly without line of sight. Always verify your wireless network's range by performing a Site Survey.  
PꢁN 2ꢀ57ꢀ4 Rev. C  
www.bannerengineering.com - Tel: + 1 888 373 6767  
7
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
Battery Life for a Q45VA  
Q45VA Battery Curves  
30  
25  
900 MHz 250mW  
2.4 GHz  
900 MHz 1W  
20  
15  
10  
5
0
0
1
2
3
4
5
Sample and Report Time (minutes)  
8
www.bannerengineering.com - Tel: + 1 888 373 6767  
PꢁN 2ꢀ57ꢀ4 Rev. C  
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
Dimensions  
9.4 mm  
[0.37”]  
22.2 mm  
[0.88”]  
33.1 mm  
[1.3”]  
59.2 mm  
[2.33”]  
44.5 mm  
[1.75”]  
78.4 mm  
[3.09”]  
74 mm  
[2.91”]  
6.4 mm  
[0.25”]  
4x R2.6 mm  
[0.1”]  
5.8 mm  
[0.23”]  
5.7 mm  
[0.23”]  
38 mm  
[1.5”]  
32.9 mm  
[1.3”]  
6.8 mm  
[0.27”]  
30.8 mm  
[1.21”]  
Accessories  
Brackets  
BWA-BK-ꢀꢀ9  
BWA-BK-ꢀ1ꢀ  
Mounts the device to a  
surface using adhesive  
Includes a magnetic  
mounting bracket and four  
mounting screws  
Alignment mark indicates  
the front of device  
44.5 mm × 49.5 mm  
Includes a base plate, two  
screw retainers, four  
SmCo magnet with a 4ꢀ lb  
pull strength  
mounting screws, a set  
screw, and a mounting disc  
For use on flat or curved  
surfaces  
44.5 mm × 49.5 mm  
For installation instructions,  
see Q45VA Bracket  
Assembly Quick Start Guide  
(pꢁn 2ꢀ8986)  
PꢁN 2ꢀ57ꢀ4 Rev. C  
www.bannerengineering.com - Tel: + 1 888 373 6767  
9
®
Sure Cross Wireless Q45VA Vibration and Temperature Sensor  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or  
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not  
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO  
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES  
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,  
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously  
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the  
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will  
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at  
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:  
www.bannerengineering.com.  
For patent information, see www.bannerengineering.comꢁpatents.  
©
Banner Engineering Corp. All rights reserved  
厂商 型号 描述 页数 下载

BANNER

DX80N2Q45UAC [ Sure Cross® Wireless Q45UA Ultrasonic Node ] 7 页

BANNER

DX80N2Q45VTP [ Sure Cross® Wireless Q45VTP Node ] 8 页

BANNER

DX80N2X1S-P6 [ Sure Cross Performance Node ] 8 页

BANNER

DX80N2X1W-P6L [ Sure Cross® Performance Node ] 8 页

BANNER

DX80N2X6S-P6 [ Sure Cross Performance Node ] 8 页

BANNER

DX80N9Q45UAC [ Sure Cross® Wireless Q45UA Ultrasonic Node ] 7 页

BANNER

DX80N9Q45VA [ Sure Cross® Wireless Q45VA Vibration and Temperature Sensor ] 10 页

BANNER

DX80N9Q45VTP [ Sure Cross® Wireless Q45VTP Node ] 8 页

BANNER

DX80N9X1S-P6 [ Sure Cross Performance Node ] 8 页

BANNER

DX80N9X1W-P6L [ Sure Cross® Performance Node ] 8 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.204052s