PXI-2564

型号:

PXI-2564

描述:

16通道, 5 A单刀单掷( A型)继电器[ 16-Channel, 5 A SPST (Form A) Relays ]

品牌:

NI[ National Instruments ]

页数:

3 页

PDF大小:

131 K

16-Channel, 5 A SPST (Form A) Relays  
NEW  
NI PXI-2564  
• 16 independent Form A (SPST)  
nonlatching relays  
Operating Systems  
• Windows 2000/NT/XP  
• Switch capacity  
Recommended Software  
• NI Switch Executive  
• LabVIEW  
• LabWindows/CVI  
• Measurement Studio  
Up to 150 VDC/150 VAC CAT II  
Up to 5 A switching/5 A carry  
• Onboard relay counting  
• Fully software programmable  
• 32,000-step scanlist for  
deterministic scanning  
• Tight synchronization with  
instruments through hardware triggers  
• 45 cycles/s  
Other Compatible Software  
• Visual Basic  
• C/C++  
Driver/Services Software  
• NI-SWITCH  
• NI-DAQmx  
• Includes one spare relay onboard for  
field maintenance  
Overview  
Software  
The National Instruments PXI-2564 is a 5 A, general-purpose switch All National Instruments PXI and SCXI switch modules are shipped  
module in a single-slot, 3U PXI module. It has 16 independent SPST with NI-SWITCH, an IVI-compliant driver offering complete  
(Form A) relays with low contact resistance and high isolation functionality for all switch modules. For additional assistance in  
voltage. It includes over-temperature protection to ensure that the configuring, programming, and managing higher-channel-count  
relays are never exposed to an amount of power in excess of their switching systems, NI Switch Executive software offers an easy-to use,  
rating. If the current approaches the rated value, the control circuitry intelligent switch management and visual routing environment.  
opens the relay contacts. The NI PXI-2564 is ideal for switching  
medium-to-high-power signals and loads in military, automotive, or  
automated test applications.  
Ordering Information  
NI PXI-2564 ........................................................................778572-64  
Accessories  
Relay Count Tracking  
The PXI-2564 counts relay closures on each of its high-power relays.  
The counts are stored onboard and can be retrieved as necessary for  
predictive maintenance to reduce unexpected system downtime.  
NI Switch Executive  
Development System ......................................................778546-01  
Deployment Engine ........................................................778548-00  
BUY NOW!  
For complete product specifications, pricing, and accessory  
information, call (800) 813-3693 (U.S. only) or go to  
ni.com/switches  
Automatic Scanning  
The PXI-2564 maximizes throughput in automated test applications  
by the use of scanning. Scanning improves throughput by  
downloading a list of up to 32,000 connections to the switch  
and cycling through the list using an event (trigger) without  
any interruption from the host processor. Scanning is most  
efficiently accomplished by mating the PXI-2564 with a companion  
modular instrument that will issue a trigger after each measurement  
is complete.  
16-Channel, 5 A SPST (Form A) Relays  
Specifications  
Relay Characteristics  
Environment  
Number of channels......................................... 16  
Relay type......................................................... SPST, normally open, nonlatching  
Maximum switching voltage  
Operating temperature..................................... 0 to 55 °C  
Storage temperature........................................ -20 to 70 °C  
Relative humidity ............................................. 5 to 85% noncondensing  
Channel-to-channel ................................... 150 VDC, 150 VAC  
Channel-to-ground..................................... 150 VDC, 150 VAC, CAT II  
Maximum switching current ............................ 5 A  
Maximum carry current.................................... 5 A  
Simultaneous channels at maximum current..... 16  
Maximum AC switching power........................ 750 VA  
Maximum DC switching power  
Pollution degree ...............................................  
Approved at altitudes up to 2000 m  
2
Safety  
This product is designed to meet the requirements of the following standards of safety for electrical  
equipment for measurement, control, and laboratory use:  
• IEC 61010-1, EN 61010-1  
• UL 61010-1  
• CAN/CSA C22.2 No. 61010-1  
150 W at 30 V  
30 W at 150 V  
DC path resistance  
Electromagnetic Compatibility  
Initial.......................................................... <100 m  
End of life .................................................. 250 mΩ  
Minimum switching capacity........................... 10 mA or 5 VDC  
CE, C-Tick, and FCC Part 15 (Class A) Compliant  
Emissions.......................................................... EN 55011 Class A at 10 m  
FCC ................................................................... Part 15A above 1 GHz  
Immunity........................................................... EN 61326:1997 +A2:2001, Table 1  
Dynamic Characteristics  
Maximum cycle speed ..................................... 45 cycles/s  
Relay operate time  
CE Compliance  
This product meets the essential requirements of applicable European Directives, as amended for  
Maximum................................................... 10.4 ms  
Expected relay life  
CE Marking, as follows:  
Low-Voltage Directive (safety)......................... 73/23/EEC  
Electromagnetic Compatibility  
Mechanical................................................ 5x107 cycles  
Electrical  
Directive (EMC) ................................................ 89/336/EEC  
Full load .............................................. 1x105 cycles  
Physical  
Relay type......................................................... Armature, nonlatching  
Relay contact material ..................................... Gold flash over silver alloy  
I/O connector.................................................... 37-pin D-Sub, male  
Dimensions....................................................... Single PXI slot, 3U  
2
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com  
NI Services and Support  
NI has the services and support to meet your  
needs around the globe and through the  
application life cycle – from planning  
and development through deployment  
Local Sales and Technical Support  
In offices worldwide, our staff is local to the country, giving you  
access to engineers who speak your language. NI delivers industry-  
leading technical support through online knowledge bases, our  
applications engineers, and access to 14,000 measurement and  
automation professionals within NI Developer Exchange forums.  
Find immediate answers to your questions at ni.com/support.  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of  
technical support. Visit ni.com/ssp.  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
SERVICE  
NEEDS  
Training and Certification  
NI training is the fastest, most certain route to productivity with our Hardware Services  
products. NI training can shorten your learning curve, save NI Factory Installation Services  
development time, and reduce maintenance costs over the NI Factory Installation Services (FIS) is the fastest and easiest way to  
application life cycle. We schedule instructor-led courses in cities use your PXI or PXI/SCXI combination systems right out of the box.  
worldwide, or we can hold a course at your facility. We also offer a Trained NI technicians install the software and hardware and  
professional certification program that identifies individuals who configure the system to your specifications. NI extends the standard  
have high levels of skill and knowledge on using NI products. warranty by one year on hardware components (controllers, chassis,  
Visit ni.com/training.  
modules) purchased with FIS. To use FIS, simply configure your  
system online with ni.com/pxiadvisor.  
Professional Services  
Our Professional Services Team is comprised of NI applications Calibration Services  
engineers, NI Consulting Services, and a worldwide NI Alliance NI recognizes the need to maintain properly calibrated devices for  
Partner Program of more than 600 independent consultants and high-accuracy measurements. We provide manual calibration  
integrators. Services range procedures, services to recalibrate your products, and automated  
from start-up assistance to calibration software specifically designed for use by metrology  
turnkey system integration. laboratories. Visit ni.com/calibration.  
Visit ni.com/alliance.  
Repair and Extended Warranty  
OEM Support  
NI provides complete repair services for our products. Express repair  
We offer design-in consulting and product integration assistance and advance replacement services are also available. We offer  
if you want to use our products for OEM applications. For extended warranties to help you meet project life-cycle requirements.  
information about special pricing and services for OEM customers, Visit ni.com/services.  
visit ni.com/oem.  
ni.com • (800) 433-3488  
National Instruments • Tel: (512) 683-0100 • Fax: (512) 683-9300 • info@ni.com  
© 2004 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, NI-DAQ, NI Alliance Partner, ni.com, and SCXI  
are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.  
厂商 型号 描述 页数 下载

NI

PXI-1033 PXI机箱,集成MXI- Express远程控制器[ PXI Chassis with Integrated MXI-Express Remote Controller ] 6 页

NI

PXI-1050 PXI机箱,集成了信号调理[ PXI Chassis with Integrated Signal Conditioning ] 5 页

NI

PXI-1052 PXI机箱,集成了信号调理[ PXI Chassis with Integrated Signal Conditioning ] 5 页

ETC

PXI-2000 4 - CH十六分之十四位最多2 MS / s同步采样多功能数据采集卡[ 4-CH 14/16-Bit Up to 2 MS/s Simultaneous-Sampling Multi-Function DAQ Cards ] 2 页

ETC

PXI-2005 [ Supports a 32-bit 3.3 V or 5 V PCI bus (DAQ-2000 series) ] 3 页

ETC

PXI-2006 [ Supports a 32-bit 3.3 V or 5 V PCI bus (DAQ-2000 series) ] 3 页

ETC

PXI-2010 [ Supports a 32-bit 3.3 V or 5 V PCI bus (DAQ-2000 series) ] 3 页

ETC

PXI-2020 8月16日,通道16位250 kS / s的同步采样数据采集卡[ 8/16-CH 16-Bit 250 KS/s Simultaneous Sampling DAQ Cards ] 2 页

ETC

PXI-2022 8月16日,通道16位250 kS / s的同步采样数据采集卡[ 8/16-CH 16-Bit 250 KS/s Simultaneous Sampling DAQ Cards ] 2 页

ETC

PXI-2200 64通道12位/ 16位最多3个MS / s的多功能数据采集卡[ 64-CH 12/16-Bit Up to 3 MS/s Multi-Function DAQ Cards ] 2 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.201482s