EXQ125-48S1V8

型号:

EXQ125-48S1V8

描述:

36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ]

品牌:

ARTESYN[ ARTESYN TECHNOLOGIES ]

页数:

2 页

PDF大小:

49 K

EXQ125 Series  
S i n g l e o u t p u t  
DC/DC CONVERTERS 36-100W High Efficiency DC/DC Converters  
1
Ultra-high efficiency topology, 91% at 3.3V,  
88% typical at 1.8V  
Industry standard footprint  
Wide baseplate temperature, -40°C to +100°C  
90% to 110% output trim  
No minimum load  
Overvoltage protection  
Remote on/off  
The EXQ125 is a new ultra-high efficiency, open frame, isolated converter series in  
an industry standard quarter-brick footprint that provides up to 100 watts of output  
power. The EXQ125 delivers very high output current at low voltages, and excellent  
useable power density for todays high end applications. The seven models in the  
series feature an input voltage range of 33 to 75VDC and are available in output  
voltages of 12V, 5V, 3.3V, 2.5V, 1.8V, 1.5V and 1.2V. The output voltage on each  
model is adjustable from 90% to 110% of the nominal value. The EXQ125 series  
also has a remote on/off capability. Overcurrent and overvoltage protection features  
are included as standard. With full international safety approval including EN60950  
(TÜV Rheinland) and UL/cUL1950, the EXQ125 reduces compliance costs and time  
to market.  
TÜV  
2 YEAR WARRANTY  
All specifications are typical at nominal input, full load at 25°C unless otherwise stated  
SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
Voltage adjustability  
EMC CHARACTERISTICS  
90% to 110%  
±1.5% max.  
±0.1% max.  
0.2% max.  
0A  
Conducted emissions  
EN55022 (See Note 2)  
Level A  
Level B  
Level B  
EN55022 (See Note 2)  
Set point accuracy  
Radiated emissions  
Immunity:  
EN55022  
Line regulation  
Load regulation  
Minimum load  
Overshoot  
Low line to high line  
ESD air  
ESD contact  
EN61000-4-2 8kV (NP), 15kV (NP)  
EN61000-4-2 6kV (NP), 8kV (NP)  
Full load to min. load  
Radiated field enclosure EN61000-4-3 10V/m (NP)  
Conducted (DC power) EN61000-4-6 10V (NP)  
Conducted (signal)  
Input transients  
EN61000-4-6 10V (NP)  
ETS 300 132-2, ETR 283  
At turn-on and turn-off  
None  
Undershoot  
1.2V, 1.5V, 1.8V, 2.5V  
and 3.3V models  
None  
GENERAL SPECIFICATIONS  
Ripple and noise  
5Hz to 20MHz  
60mV pk-pk  
20mV rms  
Efficiency  
See table  
Operational  
Input/output  
Input/baseplate  
1500VDC  
1500VDC  
Transient response  
(See Note 1)  
2% typ. deviation  
100µs recovery to  
within 1% of setpoint  
Switching frequency  
Fixed  
400kHz typ.  
Approvals and  
standards (See Note 4)  
EN60950 (TÜV Rheinland)  
UL/cUL1950  
INPUT SPECIFICATIONS  
Input voltage range  
Input current  
48Vin nominal  
33 to 75VDC  
Material flammability  
Weight  
UL94V-0  
No load  
Remote OFF  
85mA  
20mA  
45g (1.6oz)  
MTBF  
MIL-HDBK-217F  
@ 25°C, 100% load  
ground benign  
>300,000 hours  
Input current (max.)  
(See Note 3)  
3.5A max. @ Io max.  
and Vin = 33 to 75V  
Input reflected ripple  
(See Note 5)  
300mA (pk-pk) typ.  
ENVIRONMENTAL SPECIFICATIONS  
Thermal performance Operating baseplate  
Active high remote ON/OFF  
Logic compatibility  
ON  
OFF  
(See Note 7)  
Open collector ref to -input  
Open circuit or >4.0VDC  
<1.2VDC  
-40°C to +100°C  
-40°C to +125°C  
temperature  
Non-operating  
Undervoltage lockout  
Power up  
Power down  
32.5V (typ)  
30.5V (typ)  
Start-up time  
(See Note 6)  
Power up  
Remote ON/OFF  
6ms (typ)  
2ms (typ)  
File Name: EXQ125S.PDF Rev: 18 June 2002  
EXQ125 Series  
S i n g l e o u t p u t  
DC/DC CONVERTERS 36-100W High Efficiency DC/DC Converters  
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
OUTPUT  
POWER  
(MAX.)  
OUTPUT  
OUTPUT  
REGULATION  
INPUT  
OUTPUT  
VOLTAGE  
EFFICIENCY  
(TYP.)  
MODEL  
OVP  
CURRENT CURRENT  
(7,8,9)  
VOLTAGE  
NUMBER  
LINE  
LOAD  
(MIN.)  
0A  
(MAX.)  
30A  
36W  
45W  
33-75VDC  
33-75VDC  
33-75VDC  
33-75VDC  
33-75VDC  
33-75VDC  
33-75VDC  
1.45VDC  
1.8VDC  
2.3VDC  
3VDC  
1.2V  
1.5V  
1.8V  
2.5V  
3.3V  
5V  
86.5%  
87.5%  
88.0%  
90.0%  
91.0%  
92.0%  
93.0%  
±0.1%  
±0.1%  
±0.1%  
±0.1%  
±0.1%  
±0.1%  
±0.1%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
±0.2%  
EXQ125-48S1V2  
EXQ125-48S1V5  
EXQ125-48S1V8  
EXQ125-48S2V5  
EXQ125-48S3V3  
EXQ125-48S05  
EXQ125-48S12  
0A  
30A  
54W  
0A  
30A  
75W  
0A  
30A  
82.5W  
100W  
100W  
3.9VDC  
6VDC  
0A  
25A  
0A  
20A  
14.4VDC  
12V  
0A  
8.3A  
Notes  
PROTECTION  
1
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to 0.75  
lo max. and 0.75 lo max. to 0.5 lo max. Deviation varies by model, see  
Long Form Data Sheet.  
The EXQ125 meets level A and level B conducted emissions only with  
external components connected before the input pins to the converter.  
See Application Note 118.  
Short circuit protection  
Overvoltage protection  
Continuous  
Non-latching clamp  
2
TELECOM SPECIFICATION  
3
4
Recommended input fusing is a 5A HRC 200V rated fuse.  
This product is only for inclusion by professional installers within other  
equipment and must not be operated as a stand alone product.  
Measured with no external Pi filter. Significant reduction possible with  
external filter. See Application Note 118.  
Central office interface A  
ETS300-132-2, input voltage  
and current requirements  
5
CAUTION: Hazardous internal voltages and high temperatures.  
Ensure that unit is not user accessible.  
6
7
Start-up into resistive load.  
Active low remote On/Off is available. Standard product is active high.  
When ordering active low parts, designate with the Suffix ‘-R,  
e.g EXQ125-48S3V3-R.  
8
9
When ordering 0.145" pin lengths designate with the Suffix ‘-N’, if the  
product is already a -R’ suffix product then the suffix will be -RN’  
When ordering 0.110" pin lengths designate with the Suffix ‘-K’, if the  
product is already a -R’ suffix product then the suffix will be -RK’  
0.50 [12.70]  
2.000 [50.80]  
Ø0.040 [Ø1.09]  
(6 PLS)  
Ø0.060 [Ø1.52]  
(2 PLS)  
0.815 [20.70]  
4
5
6
7
8
3
0.815 [20.70 ]  
0.515 [13.08 ]  
0.215 [5.4 ]  
PIN CONNECTIONS  
0.665 [16.89]  
0.515 [13.08]  
0.365 [9.27]  
0.215 [5.46]  
0.000 [0.00]  
2
1
Bottom View  
PIN NUMBER  
FUNCTION  
+Vin  
1
2
3
4
5
6
7
8
0.070 [1.78]  
M3 x 0.5 Threaded  
Through (4 PLS)  
*
0.20 [5.08]  
On/Off  
-Vin  
*Standard available pin length.  
0.145 (3.68) and 0.110 (2.79)  
options also available. (See  
Notes 8 and 9 for ordering details)  
2.280 [57.91]  
-Vout  
1.450  
[36.83]  
1.030  
[26.16]  
Top View  
-Sense  
Trim  
ALL DIMENSIONS IN INCHES [mm]  
0.210 [5.33]  
0.210 [5.33]  
0.070  
[1.78]  
Ø0.073 [Ø1.85]  
(2 PLS)  
1.860 [47.24]  
+Sense  
+Vout  
1.030 [26.16]  
0.815 [20.70]  
0.815 [20.70]  
8
7
6
5
4
1
0.665 [16.89]  
0.515 [13.08]  
0.365 [9.27]  
0.215 [5.46]  
0.000 [0.00]  
2
3
0.515 [13.8 ]  
0.215 [5.36 ]  
0.000 [0.00]  
International Safety Standard Approvals  
Recommended  
Hole Pattern  
Ø0.128 [Ø3.25]  
(4 PLS)  
UL/cUL : UL1950 File No. E135734  
TÜV TÜV Rheinland Certificate No. R2172600  
CB Scheme No. US-TUVR-0982  
Data Sheet © Artesyn Technologies  
® 2002  
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising  
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.  
Please consult our website for the following items: Application Note Longform Data Sheet  
www.a rte s yn.com  
File Name: EXQ125S.PDF Rev: 18 June 2002  
厂商 型号 描述 页数 下载

ARTESYN

EXQ125 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S05 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S05J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S12 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S12J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S1V2 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S1V2J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S1V5 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S1V5J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S1V8J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.189454s