EXQ125-48S05J

型号:

EXQ125-48S05J

品牌:

ARTESYN[ ARTESYN TECHNOLOGIES ]

页数:

3 页

PDF大小:

97 K

EXQ125 Series  
S i n g l e o u t p u t  
DC/DC CONVERTERS  
36-100 W High Efficiency DC/DC Converters  
1
Ultra-high efficiency topology, 91% at 3.3 V,  
88% typical at 1.8 V  
Industry standard footprint  
Wide baseplate temperature, -40 °C to +100 °C  
90% to 110% output trim  
No minimum load  
Overvoltage protection  
Remote ON/OFF  
Available RoHS compliant  
The EXQ125 is a new ultra high efficiency, open-frame, isolated converter series in  
an industry standard quarter-brick footprint that provides up to 100 Watts of output  
power. The EXQ125 delivers very high output current at low voltages, and excellent  
useable power density for today’s high end applications. The seven models in the  
series feature an input voltage range of 33 Vdc to 75 Vdc and are available in output  
voltages of 12 V, 5 V, 3.3 V, 2.5 V, 1.8 V, 1.5 V and 1.2 V. The output voltage on each  
model is adjustable from 90% to 110% of the nominal value. The EXQ125 series  
also has a remote ON/OFF capability. Overcurrent and overvoltage protection  
features are included as standard. With full international safety approval including  
EN60950 (TÜV Rheinland) and UL/cUL1950, the EXQ125 reduces compliance costs  
and time to market.  
TÜV  
2 YEAR WARRANTY  
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated  
SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
Voltage adjustability  
EMC CHARACTERISTICS  
90% to 110%  
1.5% max.  
0.1% max.  
0.2% max.  
0 A  
Conducted emissions  
EN55022 (See Note 2)  
EN55022 (See Note 2)  
Level A  
Level B  
Level B  
Set point accuracy  
Radiated emissions  
Immunity:  
ESD air  
EN55022  
Line regulation  
Load regulation  
Minimum load  
Overshoot  
Low line to high line  
EN61000-4-2 8 kV (NP), 15 kV (NP)  
EN61000-4-2 6 kV (NP), 8 kV (NP)  
Full load to min. load  
ESD contact  
Radiated field enclosure EN61000-4-3 10 V/m (NP)  
Conducted (DC power)  
Conducted (signal)  
Input transients  
EN61000-4-6 10 V (NP)  
EN61000-4-6 10 V (NP)  
ETS 300 132-2, ETR 283  
At turn-on and turn-off  
1.2 V, 1.5 V (Z), 1.8 V (Z),  
None  
Undershoot  
None  
2.5 V (Z) and 3.3 V (Z) models  
GENERAL SPECIFICATIONS  
Ripple and noise  
5 Hz to 20 MHz 60 mV pk-pk  
Efficiency  
See table  
20 mV rms  
Operational  
Input/output  
Input/baseplate  
1500 Vdc  
1500 Vdc  
Transient response  
(See Note 1)  
2% typ. deviation  
100 µs recovery to  
within 1% of setpoint  
Switching frequency  
Fixed  
400 kHz typ.  
Approvals and  
standards (See Note 4)  
EN60950 (TÜV Rheinland)  
UL/cUL1950  
INPUT SPECIFICATIONS  
Input voltage range  
Input current  
48 Vin nominal  
33-75 Vdc  
Material flammability  
Weight  
UL94V-0  
No load  
Remote OFF  
85 mA  
20 mA  
45 g (1.6 oz)  
MTBF  
Telcordia SR-332  
@ 25 °C, 100% load  
ground benign  
2,284,281 hours  
Input current (max.)  
(See Note 3)  
3.5 A max. @ Io max.  
and Vin = 33-75 Vdc  
Input reflected ripple  
(See Note 5)  
300 mA (pk-pk) typ.  
ENVIRONMENTAL SPECIFICATIONS  
Active high remote ON/OFF  
Logic compatibility  
ON  
OFF  
Thermal performance  
Operating baseplate -40 °C to +100 °C  
temperature  
Open collector ref to -input  
Open circuit or >4.0 Vdc  
<1.2 Vdc  
Non-operating  
-40 °C to +125 °C  
Undervoltage lockout  
Power up  
Power down  
32.5 V (typ)  
30.5 V (typ)  
Start-up time  
(See Note 6)  
Power up  
Remote ON/OFF  
6 ms (typ)  
2 ms (typ)  
File Name: exq125s.pdf Rev (02): 17 Nov 2005  
EXQ125 Series  
S i n g l e o u t p u t  
DC/DC CONVERTERS  
36-100 W High Efficiency DC/DC Converters  
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
OUTPUT  
POWER  
(MAX.)  
OUTPUT  
OUTPUT  
REGULATION  
INPUT  
OUTPUT  
VOLTAGE  
EFFICIENCY  
(TYP.)  
MODEL  
OVP  
CURRENT CURRENT  
VOLTAGE  
NUMBER (8,9)  
LINE  
LOAD  
(MIN.)  
0 A  
(MAX.)  
30 A  
30 A  
30 A  
30 A  
25 A  
20 A  
8.3 A  
36 W  
45 W  
33-75 Vdc  
33-75 Vdc  
33-75 Vdc  
33-75 Vdc  
33-75 Vdc  
33-75 Vdc  
33-75 Vdc  
1.45 Vdc  
1.8 Vdc  
2.3 Vdc  
3 Vdc  
1.2 V  
1.5 V  
1.8 V  
2.5 V  
3.3 V  
5 V  
86.5%  
87.5%  
88.0%  
90.0%  
91.0%  
92.0%  
93.0%  
0.1%  
0.1%  
0.1%  
0.1%  
0.1%  
0.1%  
0.1%  
0.2%  
0.2%  
0.2%  
0.2%  
0.2%  
0.2%  
0.2%  
EXQ125-48S1V2J  
EXQ125-48S1V5J  
EXQ125-48S1V8J  
EXQ125-48S2V5J  
EXQ125-48S3V3J  
EXQ125-48S05J  
EXQ125-48S12J  
0 A  
54 W  
0 A  
75 W  
0 A  
82.5 W  
100 W  
100 W  
3.9 Vdc  
6 Vdc  
0 A  
0 A  
14.4 Vdc  
12 V  
0 A  
Part Number System with Options  
E X Q 1 2 5 - 4 8 S 1 V 2 - Z R N J  
RoHS Compliance (8)  
J = Pb-free (RoHS 6/6 compliant)  
EX = Open Frame, Through Hole  
Q = 1/4 Brick  
Pin Length of Standard Product  
Blank = 0.200” (5.08 mm)  
Pin Length of Modified Standard Product  
N = 0.145” (3.68 mm)  
Output Wattage Class  
125 = 125 Watts  
K = 0.110” (2.79 mm)  
(See Note 7)  
Input Voltage  
48 = 48 Volts (33 V to 75 V range)  
Control Logic  
Blank = Positive  
R = Negative  
Number of Outputs  
S = Single  
Blank = Standard Product  
Z = Zero Undershoot,  
Output Voltage  
Soft Turn-off Characteristic  
(Applies to 1.5 V, 1.8 V,  
1V2 = 1.2 V, 1V5 = 1.5 V etc  
2.5 V and 3.3 V models only)  
Notes  
PROTECTION  
1
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to  
0.75 lo max. and 0.75 lo max. to 0.5 lo max. Deviation varies by model, see  
Longform Datasheet.  
The EXQ125 meets level A and level B conducted emissions only with  
external components connected before the input pins to the converter.  
See Application Note 118.  
Short circuit  
Overvoltage  
Continuous  
Non-latching clamp  
2
TELECOM SPECIFICATION  
3
4
Recommended input fusing is a 5 A HRC 200 V rated fuse.  
This product is only for inclusion by professional installers within other  
equipment and must not be operated as a stand alone product.  
Measured with no external Pi filter. Significant reduction possible with  
external filter. See Application Note 118.  
Central office interface A  
ETS300-132-2, input voltage  
and current requirements  
5
6
7
8
Start-up into resistive load.  
Contact the factory for Modified Standard pin length products.  
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on  
special request, please contact your local sales representative for details.  
NOTICE: Some models do not support all options. Please contact your  
local Artesyn representative or use the on-line model number search tool  
at http://www.artesyn.com/powergroup/products.htm to find a suitable  
alternative.  
CAUTION: Hazardous internal voltages and high temperatures.  
Ensure that unit is not user accessible.  
9
File Name: exq125s.pdf Rev (02): 17 Nov 2005  
EXQ125 Series  
S i n g l e o u t p u t  
DC/DC CONVERTERS  
36-100 W High Efficiency DC/DC Converters  
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
0.50 [12.70]  
2.000 [50.80]  
Ø0.040 [Ø1.09]  
(6 PLS)  
Ø0.060 [Ø1.52]  
(2 PLS)  
0.815 [20.70]  
4
5
6
7
8
3
0.815 [20.70 ]  
0.515 [13.08 ]  
0.215 [5.4 ]  
0.665 [16.89]  
0.515 [13.08]  
0.365 [9.27]  
0.215 [5.46]  
0.000 [0.00]  
2
1
Bottom View  
0.070 [1.78]  
M3 x 0.5 Threaded  
Through (4 PLS)  
*
0.20 [5.08]  
*Standard available pin length.  
0.145 (3.68) and 0.110 (2.79)  
options also available. (See  
Notes 8 and 9 for ordering details)  
2.280 [57.91]  
1.450  
[36.83]  
1.030  
[26.16]  
Top View  
ALL DIMENSIONS IN INCHES [mm]  
0.210 [5.33]  
0.210 [5.33]  
0.070  
[1.78]  
Ø0.073 [Ø1.85]  
(2 PLS)  
1.860 [47.24]  
1.030 [26.16]  
0.815 [20.70]  
0.815 [20.70]  
8
7
6
5
4
1
0.665 [16.89]  
0.515 [13.08]  
0.365 [9.27]  
0.215 [5.46]  
0.000 [0.00]  
2
3
0.515 [13.8 ]  
0.215 [5.36 ]  
0.000 [0.00]  
Recommended  
Hole Pattern  
Ø0.128 [Ø3.25]  
(4 PLS)  
PIN CONNECTIONS  
PIN NUMBER FUNCTION  
1
2
3
4
5
6
7
8
+Vin  
On/Off  
-Vin  
-Vout  
-Sense  
Trim  
+Sense  
+Vout  
International Safety Standard Approvals  
UL/cUL : UL1950 File No. E135734  
TÜV Rheinland Certificate No. R72050216  
TÜV  
CB Scheme No. US-TUVR-2217  
Datasheet © Artesyn Technologies  
® 2005  
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising  
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.  
Please consult our website for the following items: Application Note Longform Data Sheet  
www.artesyn.com  
File Name: exq125s.pdf Rev (02): 17 Nov 2005  
厂商 型号 描述 页数 下载

ARTESYN

EXQ125 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S05 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S12 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S12J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S1V2 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S1V2J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S1V5 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S1V5J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

ARTESYN

EXQ125-48S1V8 36-100W高效率DC / DC转换器[ 36-100W High Efficiency DC/DC Converters ] 2 页

ARTESYN

EXQ125-48S1V8J [ 36-100 W High Efficiency DC/DC Converters ] 3 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.165018s