JV-N
JV-N
RELAYS
COMPACT FLAT POWER
RELAY FOR HEATER LOADS
FEATURES
• High 16 A capacity
The contacts are high capacity 16A,
125 V AC.
16
.630
• Represses contact terminal heat
The contact terminals are larger and
thicker compared to the existing JV relay.
This limits the rise in temperature of the
terminals when there is a large current
flowing to approx. 28°C 62°F (normal
current of 16 A).
22
.866
10.9
.429
• Compact, flat type with low 10.9 mm
.429 inch height
Compact flat type with low surface area
of 16 × 22 mm .630 × .866 inch and
height of 10.9 mm .429 inch.
• Conforms to the various safety
standards
UL/CSA, TÜV approved.
• High sensitivity at 200 mW
High sensitivity at 200 mW coil power
consumption.
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
Max. 30 mΩ
Silver alloy
Max. operating speed
20 cpm
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Max. 12 ms (DC 4.5 V to 48 V)
Operate time*1 (at nominal voltage)
Max. 8 ms (DC 100 V)
Contact material
Release time*2 (at nominal voltage)
Initial insulation resistance
Max. 5 ms
Nominal switching
capacity
16 A 125 V AC, 10 A 277 V AC
10 A 30 V DC, 10 A 125 V AC
Min. 1,000 MΩ (at 500 V DC)
Between open
contacts
Initial breakdown
voltage
1,000 Vrms for 1 min.
2,500 Vrms for 1 min.
Min. 4,500 V
Rating
(resistive
load)
Max. switching power
2,770 VA, 300 W
277 V AC, 30 V DC
(Detection
current: 10 mA
Max. switching voltage
Max. switching current
Min. switching capacity#1
Between contacts
and coil
16 A (AC 125 V), 10 A (DC)
100 mA, 5 V DC
Surge voltage between contact and
coil
Expected life (min. ope.)
Mechanical (at 180 cpm)
2×107
Max. 45°C (DC 4.5 V to 48 V) *3
Max. 55°C (DC 100 V)*4
Temperature rise
Sealed type
16 A 125 V AC,
10 A 30 V DC
Electrical
at resistive
Ambient temperature
–40 to 70°C –40 to 158°F
(DC 4.5 to 48 V)
–40 to 60°C –40 to 140°F
(DC 100V)
Humidity: 5 to 85 % R.H.
(Note freezing and condensing
at low temperature)
105
load
Flux-resistant type
(at 20 cpm)
3×105
Conditions in case of operation,
transport and storage*8
10 A 125 V AC
Coil
200 mW (DC 4.5 to 48 V)
600 mW (DC 100 V)
Nominal operating power
Air pressure: 86 to 106 kPa
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Functional
Shock resistance
Min. 200 m/s2{20G}*5
Min. 1,000 m/s2{100G}*6
10 to 55 Hz *7
at double amplitude of 1.6 mm
Destructive
Remarks
Functional
Vibration
* Specifications will vary with foreign standards certification ratings.
*1 Excluding contact bounce time
resistance
10 to 55 Hz at double
amplitude of 2 mm
*2 Excluding contact bounce time, without diode
*3 By resistive method; nominal voltage applied to the coil; contact carrying current:
16A, at 70°C 158°F
Destructive
Unit weight
Approx. 8g .28 oz
*4 Nominal voltage applied to the coil, at 60°C 140°F
*5 Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
*6 Half-wave pulse of sine wave: 6 ms
*7 Detection time: 10 µs
*8 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
TYPICAL APPLICATIONS ORDERING INFORMATIONS
• AV equipment: TV's, VTR's, etc.
• OA equipment
1a
F
4.5 V
–
Ex. JVN
• HA equipment
Contact arrangement
1a: 1 Form A
Protective construction
Coil voltage (DC)
Nil: Sealed type
4.5, 6, 9, 12,
F: Flux-resistant type
18, 24, 48, 100 V
UL/CSA, TÜV approved type is standard.