找货询价

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

QQ咨询

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

技术支持

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

售后咨询

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

MDP-100T

型号:

MDP-100T

品牌:

MSYSTEM[ M-SYSTEM ]

页数:

4 页

PDF大小:

119 K

MODEL: MDP-100T  
Lightning Surge Protectors for  
Electronics Equipment M-RESTER  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Surge protection type: Voltage limiting type one-port SPD  
Connection: M4 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel  
LIGHTNING SURGE PROTECTOR FOR  
AC/DC POWER SUPPLY USE (1A)  
(photovoltaic system, instrument shelter)  
Functions & Features  
Housing material: Flame-resistant resin (black)  
INSTALLATION  
• Designed for AC and specifically for DC power supplies up  
to 1 A  
Operating temperature: -20 to +80°C (-4 to +176°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
• Beneficial for protecting instruments from  
counter electromotive force by inductors and of course  
normal lightning surges entering from power supply lines  
• 1 A fuse incorporated in element circuit  
Weight:  
90 g (0.20 lb), standard  
115 g (0.25 lb), with DIN rail mounting adapter  
23.5 (.93)  
PERFORMANCE  
Max. line voltage (Uc): 120 V AC (peak voltage 170V)  
Discharge voltage:  
Lot.NO  
N1430B  
100  
(3.94)  
Line to line: 190 V  
JPAN  
MADEIN  
Line to earth: 410 V  
M•STER  
MODEL  
Voltage protection level (Up):  
Line to line: 400 V  
80 (3.15)  
mm (inch)  
Line to earth: 800 V  
Response time: ≤ 0.1 μsec.  
Leakage current:  
Line to line: ≤ 0.15 mA @ 150 V DC  
Line to earth: ≤ 0.15 mA @ 300 V DC  
Max. discharge current (Imax): 1000 A (8/ 20 μsec.)  
MODEL: MDP–100T[1]  
ORDERING INFORMATION  
• Code number: MDP-100T[1]  
Specify a code from below for [1].  
(e.g. MDP-100T/A33/Q)  
Nominal current (I ): 1.0 A  
N
Dielectric strength of the base module:  
1500 V AC @ 1 minute (G terminal to other terminals)  
Internal series resistance: ≤ 0.4 Ω (including return)  
Surge protection: IEC 61643-1 Class III  
• Specify the specification for option code /Q  
(e.g. /C01)  
[1] OPTIONS (multiple selections)  
DIN Rail Mounting Adapter  
blank: Without  
/A33: With adapter (model A-33)  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
MDP-100T SPECIFICATIONS  
ES-8226 Rev.2 Page 1/4  
http://www.m-system.co.jp/  
MODEL: MDP-100T  
CONNECTION EXAMPLES  
CONTROL ROOM  
FIELD  
M-RESTER  
1A  
M-RESTER  
1A  
S1  
S2  
P1  
P2  
S1  
S2  
P1  
P2  
Discharge  
Element  
Discharge  
Element  
R
1A  
1A  
Relay,  
Coil, etc.  
G
G
The M-RESTER must be connected with its terminals S1 and S2 faced on power source side  
in order that the fuses would be blown in case of shortcircuit of the discharge element.  
GROUNDING  
PROTECTED  
EQUIPMENT  
M-RESTER  
G
G
GROUNDING  
(100 ohms or less)  
CROSSOVER WIRE  
A crossover wire between M-RESTER ground and the ground or  
metallic housing of the equipment is required for protection.  
If the protected equipment has no ground terminal, ground the  
M-RESTER only.  
When the M-RESTER is mounted with DIN Rail Mounting Adapter,  
connect the grounding wire to the mounting screw of the M-RESTER.  
MDP-100T SPECIFICATIONS  
ES-8226 Rev.2 Page 2/4  
http://www.m-system.co.jp/  
MODEL: MDP-100T  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
STANDARD  
80 (3.15)  
53 (2.09)  
2–5 (.20) dia.  
MTG HOLE  
23.5 (.93)  
27 (1.06)  
HEAD ELEMENT  
P1  
P2  
BASE  
4–M4 TERMINAL SCREW  
S1  
S2  
GROUND TERMINAL (G)  
(used as mounting bracket)  
WITH DIN RAIL MOUNTING ADAPTER  
8.5  
(.33)  
[3.3 (.13)]  
80 (3.15)  
53 (2.09)  
27 (1.06)  
23.5 (.93)  
DIN RAIL  
35mm wide  
P1 P2  
4–M4 TERMINAL SCREW  
S1 S2  
2–M4 MOUNTING SCREW  
(used as ground terminal (G))  
MOUNTING REQUIREMENTS unit: mm (inch)  
2–M4 SCREW  
25 (.97) min.  
MDP-100T SPECIFICATIONS  
ES-8226 Rev.2 Page 3/4  
http://www.m-system.co.jp/  
MODEL: MDP-100T  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
1A  
S1  
S2  
P1  
P2  
ELEMENT  
Discharge  
Elements  
POWER  
SUPPLY  
TO EQUIPMENT  
1A  
BASE  
G
GROUND TERMINAL  
(used as mounting attachment)  
Note: When the head element is removed, the line will be open.  
Specifications are subject to change without notice.  
MDP-100T SPECIFICATIONS  
ES-8226 Rev.2 Page 4/4  
http://www.m-system.co.jp/  
厂商 型号 描述 页数 下载

POMONA

MDP 可堆叠的双香蕉插头与电缆指南[ Stackable Double Banana Plug with Cable Guide ] 1 页

POMONA

MDP-0 [ Interconnection Device ] 1 页

ADAM-TECH

MDP-003-LT [ Circular DIN Connector, 3 Contact(s), Male, Plug ] 1 页

ADAM-TECH

MDP-004-LT [ Circular DIN Connector, 4 Contact(s), Male, Plug ] 1 页

ADAM-TECH

MDP-004RC [ Circular DIN Connector, 4 Contact(s), Male, Receptacle ] 1 页

ADAM-TECH

MDP-005-LT [ Circular DIN Connector, 5 Contact(s), Male, Plug ] 1 页

ADAM-TECH

MDP-006 DIN & MINI DIN PLUGS DP , DS , MDP与MDS系列[ DIN & MINI DIN PLUGS DP, DS, MDP & MDS SERIES ] 1 页

ADAM-TECH

MDP-006-LT [ Circular DIN Connector, 6 Contact(s), Male, Plug ] 1 页

ADAM-TECH

MDP-008-LT [ Circular DIN Connector, 8 Contact(s), Male, Plug ] 1 页

MSYSTEM

MDP-100T/A33 [ Lightning Surge Protectors for Electronics Equipment M-RESTER ] 4 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.196760s