找货询价

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

QQ咨询

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

技术支持

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

售后咨询

一对一服务 找料无忧

专属客服

服务时间

周一 - 周六 9:00-18:00

L9181-02_15

型号:

L9181-02_15

品牌:

HAMAMATSU[ HAMAMATSU CORPORATION ]

页数:

4 页

PDF大小:

670 K

130 kV  
X-RAY  
SOURCE  
MICROFOCUS X-RAY SOURCE  
L9181-02  
FEATURES  
GFocal spot size: 5 µm (at 4 W)  
The focal spot of 5 µm of the sealed type X-ray tube offers sharp  
and clear X-ray images even at a high magnification.  
APPLICATIONS  
GNon-destructive inspection  
GX-ray CT  
G
No high voltage cable connection required  
[Applicable objects]  
High voltage power supply is integrated.  
•Electronic component  
•Printed circuit board  
•Plastic component  
•Metal component  
GExternal control via RS-232C interface  
GHigh power: Maximum output 39 W  
SPECIFICATIONS  
GENERAL  
Parameter  
X-ray tube voltage setting range  
X-ray tube current setting range  
X-ray tube voltage operational range 1  
X-ray tube current operational range 1  
Description / Value  
Unit  
kV  
µA  
kV  
0 to 130  
0 to 300  
40 to 130  
10 to 300  
µA  
Small focus mode  
8
Maximum output  
Middle focus mode  
Large focus mode  
Small focus mode  
Middle focus mode  
Large focus mode  
16  
39  
W
8 (5 µm at 4 W)  
X-ray focal spot size  
(Nominal value)  
20  
µm  
40  
Beryllium/0.2  
Approx. 45  
Approx. 13  
Tungsten  
X-ray output window material / Thickness  
X-ray beam angle 2  
Focus to object distance (FOD)  
Terget material  
Weight 3  
mm  
degree  
mm  
Approx. 10.5  
kg  
Communication method  
Interface: RS-232C (9-pin D-sub connector)  
RATINGS  
Parameter  
Description / Value  
+24 (+2.4, -0)  
Unit  
V
Input voltage (DC)  
Power consumption  
Read output  
Operating ambient temperature  
Storage ambient temperature  
Operating and storage humidity  
Less than 120  
Continuous rating  
+10 to +40  
W
°C  
°C  
%
0 to +50  
20 to 85 (No condensation)  
REGULATION AND STANDARD  
Parameter  
Description  
Unit  
RoHS Directive  
EN 50581 Category 9  
Emission limits: CISPR 11 Group 1 Class A  
Immunity requirements: Table 2  
EMC  
IEC/EN 61326-1  
4
CONTROL SOFTWARE  
Parameter  
Applicable PC  
Description  
Unit  
PC / AT compatible  
Windows® XP, 7  
RS-232C interface  
Applicable OS  
Interface  
NOTE: 1See the graph of the X-ray tube voltage / current operation range.  
2Reference value: With 50 % of maximum X-ray emission.  
3This weight includes the accessories of approx. 0.25 kg.  
4The control software is provided as a sample software for the purpose of MFX operation.  
The performance of the software is not guaranteed.  
!
PRECAUTIONS TO USE  
· This microfocus X-ray source generates X-rays harmful to the human body. Use sufficient caution when handling the equipment to avoid  
direct or inadvertent exposure to X-rays.  
Install the X-ray source or the X-ray tube unit in an X-ray shielded cabinet or room equipped with safety interlock functions to prevent  
accidental exposure to X-rays.  
OPERATIONAL CAUTION  
· This microfocus X-ray source generates X-rays and must therefore be used only under the supervision of qualified personnel.  
· This microfocus X-ray source shall be used in compliance with health and safety regulations enforced in order to prevent health hazards  
problems due to ionizing radiation.  
X-RAY TUBE VOLTAGE / CURRENT OPERATION RANGE  
TXPRB0024EA  
350  
LARGE FOCUS MODE  
300  
250  
MIDDLE FOCUS MODE  
200  
150  
SMALL FOCUS MODE  
100  
50  
* The X-ray tube voltage guaranteed range is 40 kV to 130 kV.  
* Operation is not guaranteed when the tube current is below 10 µA.  
0
40  
60  
80  
100  
120  
130  
TUBE VOLTAGE (kV)  
DIMENSIONAL OUTLINE (Unit: mm)  
2 × M3 DEPTH 5  
X-RAY FOCAL  
SPOT  
4 × M6 DEPTH 8  
(MOUNTING  
SCREW HOLES)  
78  
1
147.0 0.5  
4.5  
100  
44  
X-RAY BEAM ANGLE  
45°  
X-RAY FOCAL  
SPOT  
COOLING FAN  
INTERLOCK-1  
POWER DC 24  
INTERLOCK-2  
V
RS-232C  
PROTECTIVE EARTH TERMINAL  
167  
147.0 0.5  
12  
147.0 0.5  
85 MIN.  
(REFERENCE)*  
4 × M6 DEPTH 8  
(MOUNTING  
SCREW HOLES)  
1
9.5  
4 × M6 DEPTH 8  
(MOUNTING  
SCREW HOLES)  
,
* Connection cables aren t included.  
TXPRA0024EA  
RELATED PRODUCTS  
X-RAY IMAGE INTENSIFIER DIGITAL CAMERA UNIT C7336-05/-52  
The C7336 series consist of a high resolution, high contrast 4-inch X-ray image in-  
tensifier (X-ray I.I.) and a 2.8 megapixel CMOS image sensor.  
The X-ray I.I. used has a fixed field-of-view of 100 mm diameter or a 4 inches/2 in-  
ches adjustable field-of-view and an input window made of thin aluminum which is  
excellent in X-ray transmission and causes less scattering of X-rays. These features  
allow real-time detection at X-ray energy levels from about 20 keV.  
The captured images can be transferred to PC directly by interface of IEEE1394b.  
X-CUBE(COMPACT X-RAY CCD CAMERA) H8480, H8481, H8953  
TXPRF0020  
X-CUBEs are compact X-ray CCD camera designed for non-destructive inspection,  
which make X-ray imaging as easy as an ordinary CCD camera in handling. The  
H8480 and H8953 use a 2/3 type CCD coupled to large-diameter tapered FOPs  
which are coated with CsI. The H8481 uses a straight type FOP instead of the large  
FOP, achieving a high resolution of 20 Lp/mm.  
Left: H8480 Center: H8953 Right: H8481  
FOS (Fiber optic plate coated with X-ray scintillator)  
The FOS is an optical device for X-ray imaging, fabricated by coating an X-ray scintillator material over a fiber optic plate consisting  
of more than tens of million glass fibers each a few micrometers in diameter. The FOS provides higher sensitivity and resolution  
than currently used sensitized paper films and also allows real-time digital radiography when directly coupled to a commercially  
available CCD. The fiber optic plate used in the FOS has excellent X-ray absorption characteristics, so that X-rays penetrating the  
X-ray scintillator and directly entering the CCD are minimized to less than 1 %. This protects the CCD from the deterioration and in-  
creased noise caused by X-ray irradiation, assuring a long service life and maintaining high image quality.  
Various sizes and shapes of FOS are available to meet your particular needs, including tapered FOP types.  
TMCPF0072  
IStructure  
Protection Film  
Scintillator : CsI(Tl)  
FOP  
(Fiber optic plate)  
2D Image-Device  
Windows® is a registered trademark of Microsoft Corporation in the United States and/or other countries.  
Other product and software names mentioned herein may be either registered trademarks or trademarks of their respective owners.  
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.  
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are  
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2015 Hamamatsu Photonics K.K.  
www.hamamatsu.com  
HAMAMATSU PHOTONICS K.K.  
HAMAMATSU PHOTONICS K.K., Electron Tube Division  
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205  
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com  
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de  
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr  
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: info@hamamatsu.co.uk  
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 SE-164 40 Kista, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se  
TXPR1015E02  
NOV. 2015 IP  
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39)02-93581733, Fax: (39)02-93581741 E-mail: info@hamamatsu.it  
China: Hamamatsu Photonics (China) Co., Ltd.: B1201 Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: hpc@hamamatsu.com.cn  
厂商 型号 描述 页数 下载

ENERGIZER

L91 1.5伏14.5克(0.5盎司) 8.0立方厘米( 0.5立方英寸)[ 1.5 Volts 14.5 grams (0.5 oz.) 8.0 cubic centimeters (0.5 cubic inch) ] 2 页

LG

L9110 [ L9110是为控制和驱动电机设计的两通道推挽式功率放大专用集成电路器件 ] 3 页

LG

L9110S - 12号的铝制车身绘( RAL 7032 ) 3 页

ETC

L9122 50欧姆同轴电缆[ 50 OHM COAXIAL CABLE ] 1 页

GILWAY

L914 行灯丝灯泡[ Line Filament Lamps ] 1 页

KINGBRIGHT

L914AD [ SINGLE COLOR LED, YELLOW, 4 mm ] 6 页

KINGBRIGHT

L914GT [ SINGLE COLOR LED, GREEN, 3 mm, ROHS COMPLIANT PACKAGE-2 ] 6 页

KINGBRIGHT

L914HT [ SINGLE COLOR LED, BRIGHT RED, 3 mm, 2 X 3 MM, ROHS COMPLIANT PACKAGE-2 ] 5 页

KINGBRIGHT

L914ID [ 暂无描述 ] 6 页

GILWAY

L918 行灯丝灯泡[ Line Filament Lamps ] 1 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.267908s