Additional Resources: Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
date 03/10/2020 │ page 2 of 6
INPUT
parameter
filter
conditions/description
capacitor filter
min
min
typ
max
units
no-load input current
positive outputs
0.1
1
mA
OUTPUT
parameter
conditions/description
typ
max
units
for positive output applications
for negative output applications
680
330
μF
μF
maximum capacitive load
voltage accuracy
at full load, input voltage range
3.3 Vdc output model
all other models
±2
±2
±4
±3
%
%
line regulation
load regulation
at full load, input voltage range
at nominal input, 10~100% load
±0.2
±0.4
±0.4
±0.6
%
%
at nominal input voltage, full load
3.3/5 Vdc output models
all other models
switching frequency
420
580
520
680
620
780
kHz
kHz
transient recovery time
transient response deviation
temperature coefficient
at nominal input voltage, 25% load step change
at nominal input voltage, 25% load step change
Operating ambient temperature -40°C to +85°C
0.1
50
1
ms
mV
300
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
min
typ
typ
max
max
units
units
short circuit protection
continuous, auto recovery
SAFETY AND COMPLIANCE
parameter
safety approvals
conducted emissions
radiated emissions
ESD
conditions/description
UL 60950-1
CISPR22/EN55022, class B (external circuit required, see Figure 4-b)
CISPR22/EN55022, class B (external circuit required, see Figure 4-b)
IEC/EN61000-4-2, contact ± 4kV, criteria B
radiated immunity
EFT/burst
IEC/EN61000-4-3, 10V/m, criteria A
IEC/EN61000-4-4, ± 1kV, criteria B (external circuit required, see Figure 4-a)
surge
IEC/EN61000-4-5, line-line ± 1kV, criteria B (external circuit required, see Figure 4-a)
IEC/EN61000-4-6, 3 Vr.m.s, criteria A
conducted immunity
MTBF
as per MIL-HDBK-217F, 25°C
yes
2,000,000
hours
RoHS
cui.com