PXI-8101RT

型号:

PXI-8101RT

描述:

2.0 GHz的英特尔赛扬575的实时嵌入式控制器PXI为[ 2.0 GHz Intel Celeron 575 Real-Time Embedded Controllers for PXI ]

品牌:

NI[ National Instruments ]

页数:

5 页

PDF大小:

921 K

2.0 GHz Intel Celeron 575  
Real-Time Embedded Controllers for PXI  
NI PXI-8101 RT NEW!  
◾  
Intel Celeron 575 processor  
(2.0 GHz single core)  
Development System  
Requirements (Windows)  
◾  
◾  
◾  
◾  
1 GB (1 x 1 GB DIMM) RAM (standard)  
2 GB (1 x 2 GB DIMM) RAM (maximum)  
Execution target for NI LabVIEW  
Real-Time or LabWindows/CVI  
Real-Time applications  
LabVIEW 8.6.1 or later  
LabVIEW Real-Time Module 8.6.1  
◾  
or later  
Or  
◾  
LabWindows/CVI  
◾  
◾  
◾  
◾  
◾  
Reliable and deterministic operation  
Ethernet control of PXI  
Watchdog timer  
Up to 20 percent faster PID  
performance than PXI-8104 RT  
LabWindows/CVI Real-Time Module  
Deployment Software (included)  
◾  
OS and drivers already installed  
Hard-drive-based image recovery  
◾  
PXI System Configuration  
◾  
Complete PXI system configuration  
at ni.com/pxiadvisor  
I/O, and instrumentation. Communicate with peripheral devices through CAN,  
GPIB, Ethernet, or serial protocols. Use NI-VISA to integrate third-party  
PXI/CompactPCI modules in your application.  
Overview  
National Instruments RT Series PXI embedded controllers deliver a flexible,  
rugged platform for your deterministic, real-time measurement and control  
applications. The NI PXI-8101 RT controller with its 2.0 GHz single-core  
processor, 1 GB standard RAM, and 800 MHz DDR2 memory offers an ideal  
balance of performance and value for real-time test and control applications.  
You develop your LabVIEW application with the LabVIEW Real-Time Module on  
Windows and download the program to your PXI-8101 RT controller via Ethernet.  
The embedded code executes on a real-time OS. Thus, you use the powerful and  
flexible development tools of LabVIEW to build reliable, real-time solutions.  
LabVIEW Real-Time applications running on PXI systems achieve microsecond  
loop rates with only 3 to 4 ns of system jitter. These real-time measurement  
and control systems capitalize on Intel processors combined with the advanced  
timing, triggering, and I/O synchronization benefits of PXI. Furthermore, NI  
measurement services software extends the timing capabilities of PXI to deliver  
tight integration with LabVIEW Real-Time applications through operations such  
as hardware-timed software loops.  
In addition, the PXI-8101 RT controller includes an external SMB connection  
for use as a trigger input, output, or watchdog timer. Use the external SMB to  
pass trigger and timing signals into and out of the PXI trigger bus in your system.  
Intel Celeron 575 Processor  
CPU  
(2.0 GHz Single Core)  
1 GB (1 x 1 GB)  
2 GB (1 x 2 GB)  
80 GB SATA  
Optional1  
800 MHz DDR2 RAM, standard  
800 MHz DDR2 RAM, maximum  
Storage, hard drive (minimum)  
Storage, solid state  
Extended temperature and 24/7  
operation option  
10/100/1000BASE-TX (Gigabit) Ethernet  
Serial port (RS232)  
4
4
4
2
Parallel port  
Hi-Speed USB ports  
Connect to Any I/O  
Watchdog/trigger SMB  
4
1Optional 32 GB solid-state drive can replace the hard drive.  
The modularity of PXI and open development environment of LabVIEW make  
it easy to integrate a variety of I/O within your application. Create a custom  
real-time embedded solution using a PXI-8101 RT embedded controller with  
any number and combination of PXI/CompactPCI plug-in modules.  
Built-in LabVIEW libraries help you create applications with data acquisition,  
dynamic signal acquisition, motion control, image acquisition, reconfigurable  
Table 1. NI PXI-8101 RT Features  
2.0 GHz Intel Celeron 575  
Real-Time Embedded Controllers for PXI  
Create Reliable Stand-Alone Systems  
To ensure reliable operation, embedded LabVIEW Real-Time applications  
continue to run even if the host PC is interrupted or rebooted. Because the  
PXI-8101 RT embedded controller runs in a separate chassis with a dedicated  
power supply, the operator can shut down the host computer entirely without  
disrupting the real-time program.  
Ordering Information  
To order a complete PXI system based on a LabVIEW Real-Time  
embedded controller, visit ni.com/pxiadvisor.  
Controller Model  
NI PXI-8101 RT.............................................................................. 780955-33  
Step 1. Select Memory Upgrade  
For stand-alone operation, you can embed code in the system so that it starts  
automatically when the system boots, requiring no human interaction. Use the  
LabVIEW Professional Development System and LabVIEW Real-Time Module to  
compile your LabVIEW application into an executable and download it to your  
PXI-8101 RT controller.  
Standard  
1 GB (1 x 1 GB DIMM)  
Recommended upgraded memory configurations  
2 GB (1 x 2 GB DIMM must be purchased)  
2 GB DDR2 RAM ........................................................................780446-2048  
Step 2. Select Storage Options  
Dual-Boot Option  
250 GB standard temperature HDD...............................................779175-06  
32 GB solid-state HDD...................................................................779175-08  
Step 3. Select Accessories  
You can configure NI PXI embedded controllers to boot into Windows or the  
real-time OS. NI Measurement & Automation Explorer (MAX) includes features  
for installing and configuring PXI embedded controllers as LabVIEW Real-Time  
targets. The controllers use a hardware switch or BIOS setting to boot into the  
desired OS.  
IEEE 1284 parallel port cable adapter (6 in.)..................................777169-01  
NI PXI-8252 IEEE 1394 interface module.......................................778925-01  
The result is a PXI embedded controller that can run embedded LabVIEW  
Real-Time or Windows applications. When the controller is in real-time mode,  
you need another Windows computer to develop and debug the LabVIEW  
Real-Time code for the PXI controller. To enable a Windows PXI embedded  
controller to dual boot with the real-time OS, you must purchase the  
LabVIEW Real-Time embedded deployment software for the controller.  
BUY NOW  
For complete product specifications, pricing, and accessory information,  
call 800 813 3693 (U.S.) or go to ni.com/pxi.  
Loop Rates (kHz)  
DAQ  
I/O Mode  
Benchmark  
Processing Channels  
NI PXI-8101 RT NI PXI-8104 RT  
1
1
Polling  
Interrupt  
Polling  
112  
39  
66  
28  
30  
24  
93  
37  
55  
26  
27  
22  
4
Analog Input  
and Output  
PID  
4
Interrupt  
Polling  
16  
16  
Interrupt  
Table 1. Maximum loop rates for LabVIEW Real-Time PXI systems are shown. All  
benchmarks use the LabVIEW Real-Time Module Version 8.6.1 with NI-DAQmx Version 8.9.  
Benchmarks that do not test network performance run on a headless target without a  
direct Ethernet connection for maximum performance. Benchmarks that do test network  
performance use interrupt-mode Ethernet via a direct connection between the host PC and  
real-time target with a crossover cable. Visit ni.com or contact National Instruments for  
additional benchmarks.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
2
2.0 GHz Intel Celeron 575  
Real-Time Embedded Controllers for PXI  
Environment  
Maximum altitude................................. 2,000 m (800 mbar)  
Specifications  
Specifications subject to change without notice.  
(at 25 °C ambient temperature)  
Features  
Pollution degree....................................  
Indoor use only.  
2
Processor............................................... 2.0 GHz Intel Celeron 575  
Chipset .................................................. Mobile Intel GM45 Express Chipset  
Front-side bus........................................ 1066 MHz  
System memory (RAM) ......................... 1 GB DDR2 RAM PC2 6400 (standard)  
2 GB DDR2 RAM PC2 6400 (maximum)  
Operating Environment  
Ambient temperature range1 ................ 5 to 50 °C2  
(tested in accordance with  
IEC-60068-2-1 and IEC-60068-2-2)  
Relative humidity range........................ 10 to 90% noncondensing  
(tested in accordance with  
Ethernet................................................. 10/100/1000BASE-TX, RJ45 connector  
Hard drive.............................................. 80 GB minimum, internal 2.5 in.,  
9.5 mm Serial ATA 1.0 interface  
IEC-60068-2-56)  
1For chassis that are not available in the online catalog at ni.com,  
contact National Instruments for supported operating temperatures.  
25 to 40 °C for the NI PXI-1000B DC.  
Video ..................................................... Integrated Graphics  
(Mobile Intel GM45 Express Chipset)  
Serial..................................................... 1 (RS232)  
Parallel .................................................. IEEE 1284 Type C miniature connector  
(adapter cable not included)  
Storage Environment  
Ambient temperature range.................. -40 to 65 °C  
Hi-Speed USB........................................  
Power Requirements  
Voltage (V)  
2
(tested in accordance with  
IEC-60068-2-1 and IEC-60068-2-2)  
Relative humidity range........................ 5 to 95% noncondensing  
(tested in accordance  
Current (A)  
Typical  
Maximum  
3.00  
with IEC-60068-2-56)  
+3.3  
+5  
2.25  
3.50  
5.5  
Shock and Vibration  
Operating shock .................................... 30 g peak, half-sine, 11 ms pulse  
+12  
-12  
0.001  
0.00  
0.075  
0.00  
(tested in accordance with  
Physical  
IEC-60068-2-27; test profile developed  
in accordance with MIL-PRF-28800F)  
Random vibration  
Board dimensions.................................. 2-slot 3U PXI module  
2 by 13 by 21.6 cm  
(1.59 by 5.1 by 8.5 in.)  
Operating.......................................... 5 to 500 Hz, 0.3 grms  
(with solid-state hard drive)  
Slot requirements.................................. One system slot plus one  
controller expansion slot  
Nonoperating.................................... 5 to 500 Hz, 2.4 grms  
(tested in accordance with  
Compatibility......................................... Fully compatible with PXI Specification  
Weight................................................... 0.983 kg (2.17 lb) typical  
IEC-60068-2-64; nonoperating test  
profile exceeds the requirements of  
MIL-PRF-28800F, Class 3)  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
3
2.0 GHz Intel Celeron 575  
Real-Time Embedded Controllers for PXI  
Safety Compliance  
◾  
IEC 61010-1, EN 61010-1  
◾  
UL 61010-01, CSA 61010-1  
Electromagnetic Compatibility  
◾  
EN 61326 (IEC 61326): Class A emissions; Basic immunity  
◾  
EN 55011 (CISPR 11): Group 1, Class A emissions  
◾  
AS/NZS CISPR 11: Group 1, Class A emissions  
◾  
FCC 47 CFR Part 15B: Class A emissions  
◾  
ICES-001: Class A emissions  
CE Compliance  
This product meets the essential requirements of applicable European Directives,  
as amended for CE marking, as follows:  
◾  
2006/95/EC; Low-Voltage Directive (safety)  
◾  
2004/108/EC; Electromagnetic Compatibility Directive (EMC)  
Refer to the Declaration of Conformity (DoC) for this product for any additional  
regulatory compliance information. To obtain the DoC for this product, visit  
ni.com/certification, search by model number or product line, and click the  
appropriate link in the Certification column.  
Waste Electrical and Electronic Equipment (WEEE)  
EU Customers: At the end of their life cycle, all products must be sent to a  
WEEE recycling center. For more information about WEEE recycling centers and  
National Instruments WEEE initiatives, visit ni.com/environment/weee.htm.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
4
NI Services and Support  
NI has the services and support to meet  
Local Sales and Technical Support  
In offices worldwide, our staff is local to the country, giving you access to  
engineers who speak your language. NI delivers industry-leading technical  
support through online knowledge bases, our applications engineers,  
and access to 14,000 measurement and automation professionals within NI  
Developer Exchange forums. Find immediate answers to your questions at  
ni.com/support.  
I
your needs around the globe and through  
A
the application life cycle – from planning  
and development through deployment and  
SERVICE  
NEEDS  
ongoing maintenance. We offer services  
and service levels to meet customer  
requirements in research, design, validation,  
and manufacturing.  
P
E
V
Y
We also offer service programs that provide automatic upgrades to your  
application development environment and higher levels of technical support.  
Visit ni.com/ssp.  
Visit ni.com/services.  
Training and Certification  
NI training is the fastest, most certain route to productivity with our products.  
NI training can shorten your learning curve, save development time, and reduce  
maintenance costs over the application life cycle. We schedule instructor-led  
courses in cities worldwide, or we can hold a course at your facility. We also  
offer a professional certification program that identifies individuals who have  
high levels of skill and knowledge on using NI products.  
Hardware Services  
System Assurance Programs  
NI system assurance programs are designed to make it even easier for you  
to own an NI system. These programs include configuration and deployment  
services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic  
System Assurance Program provides a simple integration test and ensures that  
your system is delivered completely assembled in one box. When you configure  
your system with the NI Standard System Assurance Program, you can select  
from available NI system driver sets and application development environments  
to create customized, reorderable software configurations. Your system arrives  
fully assembled and tested in one box with your software preinstalled. When  
you order your system with the standard program, you also receive system-  
specific documentation including a bill of materials, an integration test report,  
a recommended maintenance plan, and frequently asked question documents.  
Finally, the standard program reduces the total cost of owning an NI system  
by providing three years of warranty coverage and calibration service. Use the  
online product advisors at ni.com/advisor to find a system assurance program  
to meet your needs.  
Visit ni.com/training.  
Professional Services  
Our NI Professional Services team is composed of NI applications and systems  
engineers and a worldwide National Instruments Alliance Partner program of  
more than 600 independent consultants and integrators. Services range from  
start-up assistance to turnkey system  
integration. Visit ni.com/alliance.  
OEM Support  
We offer design-in consulting and product integration assistance if you want to  
use our products for OEM applications. For information about special pricing and  
services for OEM customers, visit ni.com/oem.  
Calibration Services  
NI recognizes the need to maintain properly calibrated devices for high-  
accuracy measurements. We provide manual calibration procedures, services  
to recalibrate your products, and automated calibration software specifically  
designed for use by metrology laboratories. Visit ni.com/calibration.  
Repair and Extended Warranty  
NI provides complete repair services for our products. Express repair and  
advance replacement services are also available. We offer extended warranties  
to help you meet project life-cycle requirements. Visit ni.com/services.  
n
ni.com 800 813 3693  
n
National Instruments info@ni.com  
©2009 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, and ni.com are trademarks of National Instruments. The mark LabWindows is  
used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade names of their  
respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.  
2009-11276-501-101-D  
厂商 型号 描述 页数 下载

NI

PXI-1033 PXI机箱,集成MXI- Express远程控制器[ PXI Chassis with Integrated MXI-Express Remote Controller ] 6 页

NI

PXI-1050 PXI机箱,集成了信号调理[ PXI Chassis with Integrated Signal Conditioning ] 5 页

NI

PXI-1052 PXI机箱,集成了信号调理[ PXI Chassis with Integrated Signal Conditioning ] 5 页

ETC

PXI-2000 4 - CH十六分之十四位最多2 MS / s同步采样多功能数据采集卡[ 4-CH 14/16-Bit Up to 2 MS/s Simultaneous-Sampling Multi-Function DAQ Cards ] 2 页

ETC

PXI-2005 [ Supports a 32-bit 3.3 V or 5 V PCI bus (DAQ-2000 series) ] 3 页

ETC

PXI-2006 [ Supports a 32-bit 3.3 V or 5 V PCI bus (DAQ-2000 series) ] 3 页

ETC

PXI-2010 [ Supports a 32-bit 3.3 V or 5 V PCI bus (DAQ-2000 series) ] 3 页

ETC

PXI-2020 8月16日,通道16位250 kS / s的同步采样数据采集卡[ 8/16-CH 16-Bit 250 KS/s Simultaneous Sampling DAQ Cards ] 2 页

ETC

PXI-2022 8月16日,通道16位250 kS / s的同步采样数据采集卡[ 8/16-CH 16-Bit 250 KS/s Simultaneous Sampling DAQ Cards ] 2 页

ETC

PXI-2200 64通道12位/ 16位最多3个MS / s的多功能数据采集卡[ 64-CH 12/16-Bit Up to 3 MS/s Multi-Function DAQ Cards ] 2 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.221493s