Performance Specifications
Performance Specifications
Table 1. Electrical Performance
Parameter
Symbol
Min
Typical
Maximum
Units
Supply
Voltage1
Current2
VDD
IDD
3.135
3.3
3.465
40
V
mA
Frequency
Nominal Frequency3
Absolute Pull Range 2,6, ordering option
Linearity2
fN
77.76
160.00
MHz
ppm
%
APR
Lin
KV
50, 80
5
Gain Transfer2
+80
20
ppm/V
ppm
Temperature Stability
fSTAB
Outputs
Output Logic Levels2
Output Logic High
Output Logic Low
V
VOH
VOL
0.9*VDD
0.1*VDD
Load
Rise Time2,4
IOUT
tR
15
5
pF
ns
Fall Time2,4
tF
5
ns
Symmetry2
Period Jitter, RMS5,7 (155.520 MHz)
Period Jitter, pk-pk5,7 (155.520MHz)
SYM
фJ
45
50
3.0
23
55
%
ps
фJ
ps
Phase Noise8
10Hz
100Hz
dBc/Hz
-57
-87
1kHz
10kHz
100kHz
1MHz
10MHz
-118
-146
-154
-154
-154
Control Voltage
Control Voltage Range for Pull Range
Control Voltage Input Impedance
Control Voltage Modulation BW
Output Enable/Disable9
Output Enabled
VC
ZIN
0.3
3.0
V
KΩ
kHz
V
100
BW
10
VIH
VIL
0.9*VDD
Output Disabled
0.1*VDD
10
Start-Up Time
TS
ms
°C
Operating Temp, Ordering Option
Package Size
TOP
0/70, -20/70, or -40/85
5.0 x 7.0 x 1.8
mm
1] The power supply should have by-pass capacitors as close to the supply and to ground as possible, for examples 0.1 and 0.01uF
2] Parameters are tested with production test circuit below (Fig 1).
3] See Standard Frequencies and Ordering Information tables for more specific information
4] Measured from 20% to 80% of a full output swing (Fig 2).
5] Not tested in production, guaranteed by design, verified at qualification.
6] Tested with Vc = 0.3V to 3.0V unless otherwise stated in part description
7] Broadband Period Jitter measured using Wavecrest SIA3300C, 90K samples.
8] Phase Noise is measured with an Agilent E5052A.
9] The Output is Enabled if the Enable/Disable is left open.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com