XW2D-34C6

型号:

XW2D-34C6

描述:

修身连接器端子台转换单元[ Slim Connector-Terminal Block Conversion Units ]

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

5 页

PDF大小:

520 K

Slim Connector-Terminal Block Conversion Units  
XW2D  
CSM_XW2D_DS_E_1_2  
New Slim Connector-Terminal Block  
Conversion Units.  
• Mounting area reduced by 35% (in comparison with  
40-pole XW2B Units) to contribute to downsizing  
control panels and automatic equipment.  
• Fallout prevention for terminal screws.  
• Round or forked crimp terminals can be used.  
• Mount to DIN Track or via screws.  
Unique DIN Track lock can maintain open status  
during DIN Track attachment and removal.  
• Terminal cover can be locked open.  
• Screw terminals are arranged by color in groups  
of five to simplify counting terminal numbers.  
Ordering Information  
Connectors  
Mounted Con-  
nector  
No. of  
poles  
Dimension Dimension  
Model  
Mounted Connector model Cable Connector model  
A
B
20  
34  
XW2D-20G6  
XW2D-34G6  
XW2D-40G6  
XW2D-40G6-RF *1  
XW2D-40G6-RM *2  
XW2D-50G6  
XW2D-20C6  
XW2D-34C6  
XW2D-40C6  
XW2D-50C6  
XW2D-20X6  
XW2D-34X6  
XW2D-50X6  
XW2D-20Y6  
XW2D-34Y6  
XW2D-50Y6  
79  
57  
XG4A-2031  
XG4M-2030-T  
XG4M-3430-T  
XG4M-4030-T  
XG4M-4030-T  
XG4M-4030-T  
XG4M-5030-T  
XG4M-2030-U  
XG4M-3430-U  
XG4M-4030-U  
XG4M-5030-U  
MR-20M *3  
128  
149  
149  
149  
184  
79  
100  
110  
110  
110  
144  
57  
XG4A-3431  
XG4A-4031  
XG4A  
MIL Connectors  
40  
XG4A-4031  
XG4A-4031  
50  
20  
34  
40  
50  
20  
34  
50  
20  
34  
50  
XG4A-5031  
XG4C-2031  
128  
149  
184  
79  
100  
110  
144  
57  
XG4C-3431  
XG4C  
MIL Connectors  
XG4C-4031  
XG4C-5031  
MR-20RFD2 *3  
MR-34RFD2 *3  
MR-50RFD2 *3  
MR-20RMD2 *3  
MR-34RMD2 *3  
MR-50RMD2 *3  
MR Sockets  
MR Plugs  
128  
184  
79  
100  
144  
57  
MR-34M *3  
MR-50M *3  
MR-20F*3  
128  
184  
100  
144  
MR-34F*3  
MR-50F *3  
*1. This model has built-in bleeder resistance and is used for inputs to Units with Fujitsu connectors, i.e., the CJ1W-ID231/-ID261/-MD261.  
*2. This model has built-in bleeder resistance and is used for inputs on Units with MIL connectors, i.e., the CJ1W-ID232/-ID262/-MD263/-MD563.  
*3. The MR Connector is made by Honda Tsushin Kogyo.  
Accessories (Order Separately)  
Connecting Cables for Connector-Terminal Block Conversion Units  
Refer to the XW2Z Datasheet.  
Ratings and Specifications  
Rated current  
1 A  
Rated voltage  
125 VAC, 24 VDC  
Insulation resistance  
Dielectric strength  
100 MΩ min. (at 500 VDC)  
500 VAC for 1 min (leakage current: 1 mA max.)  
Ambient operating tem-  
perature  
0 to 55°C  
1
XW2D  
Dimensions  
(Unit: mm)  
XW2D-@@G6  
Wiring Diagram  
Mounted Connector: XG4A MIL Connector  
(Example for Terminal Block with 50 Poles)  
XG4A MIL Connector  
Mounted Connector  
A
B
Two, 4.5 dia.  
(39.1)  
17.6  
2
1
4
3
6
5
46 48 50  
45 47 49  
6
40  
Triangular mark  
7
39  
7
(4.5)  
A1 A2 A3  
A23  
A24  
A25  
DIN Track lock  
5.8  
M3  
1.2  
B1 B2 B3  
B23  
B24  
B25  
Terminal Block  
Note: For all models, the odd-numbered pins on the Connec-  
tor correspond to row A on the terminal block and the  
even-numbered pins on the Connector correspond to  
row B on the terminal block.  
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.  
XW2D-40G6-RF  
XW2D-40G6-RM  
Connector (XG4A-4031)  
Connector (XG4A-4031)  
2
1
4
3
6
5
8
7
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40  
11 13 15 17 19 21 23 25 27 29 31 33 35 37 39  
Connector  
pin No.  
2
1
4
3
6
5
8
7
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40  
Connector  
pin No.  
9
9
11 13 15 17 19  
21 23 25 27 29 31 33 35 37 39  
Triangular  
mark  
Triangular  
mark  
A1 A2 A3 A4 A5 A6 A7 A8 A9  
B1 B2 B3 B4 B5 B6 B7 B8 B9  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
A17  
A18  
A19  
A20  
Terminal No.  
A1 A2 A3 A4 A5 A6 A7 A8 A9  
B1 B2 B3 B4 B5 B6 B7 B8 B9  
A10  
A11  
A12  
A13  
A14  
A15  
A16  
A17  
A18  
A19  
A20  
Terminal No.  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
B17  
B18  
B19  
B20  
B10  
B11  
B12  
B13  
B14  
B15  
B16  
B17  
B18  
B19  
B20  
Terminal Block  
Terminal Block  
Note: The dimensions shown here are the same as the XW2D-40G6.  
Note: The dimensions shown here are the same as the XW2D-40G6.  
XW2D-@@C6  
Mounted Connector: XG4C MIL Connector  
Wiring Diagram  
(Example for Terminal Block with 50 Poles)  
XG4C MIL Connector  
Mounted Connector  
(21.1)  
17.6  
A
B
Two,4.5 dia.  
2
1
4
3
6
5
46 48 50  
45 47 49  
6
40  
Triangular  
mark  
7
39  
A1 A2 A3  
B1 B2 B3  
A23  
A24  
A25  
(4.5)  
7
5.8  
DIN Track lock  
1.2  
M3  
B23  
B24  
B25  
Terminal Block  
Note: For all models, the odd-numbered pins on the Connec-  
tor correspond to row A on the terminal block and the  
even-numbered pins on the Connector correspond to  
row B on the terminal block.  
7
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.  
2
XW2D  
XW2D-@@X6  
Mounted Connector: MR Socket  
Wiring Diagram  
(Example for Terminal Block with 50 Poles)  
Mounted Connector  
(28.2)  
17.6  
A
B
Two, 4.5 dia.  
33 34 35  
19 20  
48 49 50  
32  
6
40  
1
1
2
3
3
16 17 18  
7
39  
(4.5)  
DIN track lock  
7
5.8  
M3  
1.2  
5
17 19  
45 47 49  
46 48 50  
2
4
6
16 18 20  
7
Terminal Block  
Note: There is only one DIN Track lock located in the center of the Connector for a 20-pole Unit.  
Note: Connector pin numbers correspond 1-to-1 to terminal  
block numbers on all models.  
XW2D-@@Y6  
Mounted Connector: MR Plug  
Wiring Diagram  
(Example for Terminal Block with 50 Poles)  
Mounted Connector  
A
B
(25.9)  
17.6  
Two, 4.5 dia.  
1
2
3
16 17 18  
32  
6
40  
19 20  
33 34 35  
48 49 50  
7
39  
(4.5)  
DIN Track lock  
7
5.8  
M3  
1.2  
1
3
5
17 19  
45 47 49  
46 48 50  
2
6
4
16 18 20  
7
Terminal Block  
Note: There is only one DIN Track lock located in the center of the terminal block for a 20-pole Unit.  
Note: Connector pin numbers correspond 1-to-1 to terminal  
block numbers on all models.  
3
XW2D  
Safety Precautions  
Precautions for Correct Use  
Wiring  
Mounting Units to and Removing Units from DIN Track  
• XW2D Connector-Terminal Block Conversion Units can be  
mounted side-to-side on DIN Track.  
• Always turn OFF the power supply before wiring.  
Otherwise, cables or other conductors can short the termi-  
nals and cause the Unit to fail.  
• Secure both ends of the XW2D with End Plates.  
• When removing the Unit from a DIN Track, insert a flat-head  
screwdriver into the slider and pull the lock out.  
• Do not connect or disconnect Connectors with the power  
turned ON. Otherwise, it may cause malfunctions.  
Wiring Terminal Blocks  
Using Crimp Terminals  
(With a Terminal Block with M3 Screws)  
Round crimp terminals  
Forked crimp terminals  
3.2 mm dia.  
3.2 mm  
5.8 mm max.  
5.8 mm max.  
Applicable crimp terminals  
Applicable wires  
Handling M3 Screw and Round Terminals  
Raise the M3 screw with a Phillips screwdriver as shown in di-  
agram (1) and slide the screw toward you to keep the space  
open. Follow the steps in diagrams (1) and (2) below when us-  
ing round crimp terminals.  
Round crimp ter-  
AWG 22 to 16  
1.25-3  
minals  
(0.30 to 1.25 mm2)  
Forked crimp ter-  
minals  
AWG 22 to 16  
(0.30 to 1.25 mm2)  
1.25Y-3  
Terminal Screw Tightening Torque  
Use a tightening torque of 0.7 N·m when connecting wires or  
crimp terminals to the terminal block.  
A
B
4
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  
厂商 型号 描述 页数 下载

OMRON

XW2B 简化了连接器和接线盒的更换,并且需要更少的面板布线。[ Simplifies Connector and terminal block replacement, and requires less in-panel wiring. ] 10 页

OMRON

XW2B-1 [ ACCY EXPANSION UNIT FOR XW2B ] 11 页

OMRON

XW2B-20G4 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5-D 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20J6-1B 多应用控制器:从高性能计算机C ONTROL高度可靠的过程控制[ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-3B 简化电机控制和欧姆龙位置控制PLC模块之间的接线[ Simplify Wiring between Motor Controls and Omrons Position Control PLC Modules ] 12 页

OMRON

XW2B-20J6-6 [ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-8A 自2001年以来, CJ1M系列PLC是在全球范围内广泛应用的控制。[ Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. ] 29 页

OMRON

XW2B-20X5 [ INTERFACE MOD RCPT 34POS ] 11 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.187278s