PYCM-08S

型号:

PYCM-08S

描述:

无螺钉夹紧端子插座[ Screwless Clamp Terminal Socket ]

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

6 页

PDF大小:

315 K

Screwless Clamp Terminal Socket  
PYFjjS  
H Screwless clamping greatly contributes to  
reduce wiring time  
H No over or under tightening of cable  
connection so better contact reliability is  
achieved  
H Double wiring possible on all the terminals,  
and easy bridge and branch connections  
H Use either solid or stranded wires from 0.2  
to 1.5 mm2 (AWG24 to AWG16)  
H Safe terminal arrangement: Coil terminals  
separated from contact terminals  
H Unique ejector enables easy relay  
replacement  
H Two types of nameplate are available: New  
RC  
MY and Legrand  
H Finger-protection construction  
Ordering Information  
Part number  
Item  
4-pole  
2-pole  
Socket  
PYF14S  
PYF08S  
PYCM-08S  
Clip & Release lever PYCM-14S  
Nameplate  
R99-11 nameplate for MY  
PYDM-14SR, PYDM-14SB  
Socket Bridge  
PYDM-08SR, PYDM-08SB  
Specifications  
Item  
PYF14S  
PYF08S  
Remarks  
Relay  
MY2 Series  
MY4 Series  
MY2 Series  
---  
Dimensions  
31 × 85 × 36.5 mm max. (W × H × D)  
23.2 × 85 × 36.5 mm max. (W × H × D)  
---  
Rated voltage  
Rated carry current  
250 V AC  
---  
10 A at 55°C with MY2 (S) (see note)  
5 A at 70°C with MY4 (S)  
10 A at 55°C with MY2 (S)  
7 A at 70°C with MY2 (S)  
VDE0627  
2
Applicable wires  
0.2 to 1.5 mm (AWG24 to AWG16)  
---  
Solid wire  
Stranded wires  
Number of wire  
connections  
2 wires per terminal (1 wire per hole)  
---  
2
2
Clamping force  
10 N min. (0.2 mm )  
EN60999  
40 N min. (1.5 mm )  
Note: MY2 (S) can be used at 70°C but at 7 A.  
J SAFETY STANDARDS (APPROVAL PENDING)  
VDE0627 (IEC664, EN60999)  
UL508 (UL1059)  
CSA C22.2 No. 14 (CSA C22.2 No. 158)  
1
PYFjjS  
PYFjjS  
Dimensions  
Unit: mm  
38.2 max.  
36.5 max.  
J PYF14S  
J PYF08S  
36.5 max.  
23.2 max.  
31 max.  
85 max.  
85 max.  
(5.3)  
J TERMINAL ARRANGEMENT  
PYF14S  
PYF08S  
Common contacts  
Make contacts  
Break contacts  
Coils  
Note: Pole-2 and pole-3 cannot be used with the MY2 type.  
Use pole-1 (terminal numbers: 11, 14, 12) and pole-4  
(terminal numbers: 41, 44, 42).  
J MOUNTING HEIGHT (WITH LEVER)  
PYF14S  
PYF08S  
73.6 typ.  
28.6  
72.6 typ.  
28.6  
2
PYFjjS  
PYFjjS  
Accessories (Order seperately)  
Unit: mm  
J SOCKET BRIDGE  
Insulating coating  
L
1.4 dia. conductor  
(See note 1.)  
Note: 1. The relationship between the model number, the length  
L, and the color of the insulating coating is shown in  
the following table.  
3. The positions of the ends of the insulating coating must  
not vary more than 0.5 mm.  
4. The characteristics of the socket bridge are shown in  
the following table.  
Model number  
Length L (mm)  
Color of  
insulating  
coating  
Item  
Characteristic  
10 A  
Rated ON current  
Rated insulation voltage  
Temperature rise  
Dielectric strength  
27.5±0.3  
19.7±0.3  
PYDM-14SR  
PYDM-14SB  
PYDM-08SR  
PYDM-08SB  
Red  
Blue  
Red  
Blue  
250 VAC  
35°C max.  
1,500 VAC for 1 minute  
--55 to 70°C  
Ambient operating  
temperature  
2. The insulating coating must be able to withstand a volt-  
age of 1,500 V for 1 minute. Use either PE or PA as  
the material of the insulating coating.  
J PYF14S LEVER  
J PYF08S LEVER  
16 typ.  
26.5 typ.  
28 typ.  
21.5 typ.  
6 typ.  
54.4 typ.  
4.1 typ.  
5.4 typ.  
52.5 typ.  
32.7 typ.  
6.41 typ.  
3 typ.  
29.6 typ.  
Installation  
J TOOLS  
A flat-blade screwdriver should be used to mount the cables.  
Applicable Screwdriver  
Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)  
Flat-blade, Parallel-tip  
2.5 dia. (3.0 mm max.)  
Flat-blade, Flared-tip  
Cannot be used.  
Examples:  
FACOM AEF.2.5 × 75E  
VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100  
(AEF. 3 × 75E)  
WAGO 210-119  
WIHA 260/2.5 × 40  
(260/3 × 50)  
Note: Chamfering (beveling) the tip of the driver improves insertion when used as an exclusive tool.  
3
PYFjjS  
PYFjjS  
J APPLICABLE WIRES  
Applicable Wire Sizes  
2
0.2 to 1.5 mm , AWG24 to AWG16  
Applicable Wire Type  
Solid wires, stranded wires, flexible wires, or wires with ferules  
can be used.  
Note: 1. If the overall diameter of the wire is less than 2.2 mm,  
do not insert the wire past the conductor. Refer to the  
following diagrams.  
(See note 1) < 2.2  
Diameter D (mm)  
3.2 (3.5: see note 2))  
Conductor diameter d (mm) or length of sides a and b (mm)  
1.9  
2. If theoverall diameterof thewireis over3.2 mm, it will be  
difficult to use double wiring.  
Wires with Ferules  
Examples of Applicable Wires (Confirmed Using Catalog Information)  
Type of wire  
Conductor type  
See note 1, above. Recommended wire  
sizes  
See note 2, above.  
2
2
Equipment wire 2491X  
BS6004  
Flexible  
Solid  
0.5, 0.75, 1.0 mm  
1.5 mm  
2
0.5 mm  
2
2
Switchgear BS6231  
Switchgear BS6231  
Tri-rated control and switchgear  
Conduit  
Solid  
1.0 mm  
1.5 mm  
2
2
Flexible  
Flexible  
Stranded  
Flexible  
Flexible  
Flexible  
Flexible  
0.5, 0.75 mm  
1.0 mm  
2
0.5, 0.75, 1.0, 1.5 mm  
2
1.5 mm  
UL1007  
18AWG  
16AWG  
UL1015  
18AWG, 16AWG  
UL1061  
18AWG  
18AWG  
UL1430  
16AWG  
J WIRING  
Use wires of the applicable sizes specified above. The length of  
the exposed conductor should be 8 to 9 mm.  
8 to 9 mm  
Fig. 1 Exposed Conductor Length  
2. Insert the exposed conductor into the wire connection hole.  
Use the following wiring procedure.  
1. Insert the specified screwdriver into the release hole located  
beside the wire connection hole where the wire is to be  
inserted.  
Insert  
Wire connection holes  
Release holes  
3. Pull out the screwdriver.  
Fig. 2 Wire Connection Holes and Release Holes  
Pull out  
Wire connection hole  
Release hole  
Insert  
Screwdriver  
Fig. 3 Section A-A of Fig. 2  
4
PYFjjS  
PYFjjS  
Precautions  
J PRECAUTIONS FOR CONNECTION  
J GENERAL PRECAUTIONS  
Do not move the screwdriver up, down, or from side to side while  
it is inserted in the hole. Doing so may cause damage to internal  
components (e.g., deformation of the coil spring or cracks in the  
housing) or cause deterioration of insulation.  
Use the clip to prevent relays from floating or falling out of the  
socket.  
Do not use the product if it has been dropped on the ground.  
Dropping the product may adversely affect performance.  
Do not insert the screwdriver at an angle. Doing so may break  
the side of the socket and result in a short--circuit.  
Confirm that the socket is securely attached to the mounting  
track before wiring. If the socket is mounted insecurely it may fall  
and injure the operator.  
Ensure that the socket is not charged during wiring and  
maintenance. Not doing so may result in electric shock.  
Do not pour water or cleaning agents on the product. Doing so  
may result in electric shock.  
Do not use the socket in locations subject to solvents or alkaline  
chemicals.  
Do not use the socket in locations subject to ultraviolet light (e.g.,  
direct sunlight). Doing so may result in markings fading, rust,  
corrosion or resin deterioration.  
Do not dispose of the product in fire.  
Do not insert two or more wires in the hole. Wires may come in  
contact with the spring causing a termperature rise or may be  
subject to sparks. (There are two wiring holes for each terminal.)  
J REMOVING FROM MOUNTING RAIL  
To remove the socket from the mounting rail, insert the tip of the  
screwdriver in the fixture rail and move it in the direction shown  
below.  
Insert the screwdriver along the hole wall as shown below.  
If lubricating liquid, such as oil, is present on the tip of the  
screwdriver, the screwdriver may fall out resulting in injury to the  
operator.  
Insert the screwdriver into the bottom of the hole. It may not be  
possilble to connect cables properly if the screwdriver is inserted  
incorrectly.  
5
PYFjjS  
PYFjjS  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
R
OMRON ON--LINE  
OMRON ELECTRONICS LLC  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Global -- http://www.omron.com  
USA -- http://www.omron.com/oei  
Canada -- http://www.omron.com/oci  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. J122-E3-1  
10/01  
Specifications subject to change without notice.  
Printed in U.S.A.  
厂商 型号 描述 页数 下载

OMRON

PYC-A1 通用继电器[ General Purpose Relay ] 13 页

ETC

PYC-P2 INDUSTRIERELAIS CLIP\n[ INDUSTRIERELAIS CLIP ] 1 页

ETC

PYC-P2186703 CLIP\n[ CLIP ] 1 页

ETC

PYC36DAAN-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

ETC

PYC36DAAR-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

ETC

PYC36DABN-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

ETC

PYC36DABR-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

ETC

PYC36DACN-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

ETC

PYC36DACR-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

ETC

PYC36DADN-M SQUARE门柱头球[ SQUARE POST HEADER ] 2 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.186122s