Absolute encoders - parallel
Shaft with clamping or synchro flange
Optical multiturn encoder 12 bit ST / 12 bit MT
GXP1W - parallel
Terminal significance
Terminal assignment
UB
Encoder voltage supply.
Connector
Pin 1
Core colour Assignment
GND
Encoder ground connection relating to UB.
white
Output D0
Output D1
Output D2
Output D3
Output D4
Output D5
Output D6
Output D7
Output D8
Output D9
Outputs
D0-D23
24 parallel output signals.
Pin 2
brown
green
yellow
grey
For PNP it is recommended to utilize pull-
down resistors for every data line, for NPN
pull-up resistors of 4.7 kΩ.
Pin 3
Pin 4
Pin 5
Outputs
D19 - D23
Special outputs
With inferior resolutions these outputs
may be configurated as special outputs.
Pin 6
pink
Pin 7
black
Zero setting
Input for setting a zero point anywhere
within the programmed encoder resolution.
The zero setting operation is triggered by a
High impulse and has to be in line with the
selected direction of rotation (UP/DOWN).
Connect to GND after setting operation for
maximum interference immunity. Impulse
duration >100 ms. If there is an offset
being entered by programming interface
the offset will be activated by the zero
input.
Pin 8
violet
Pin 9
grey/pink
red/blue
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
Pin 15
Pin 16
Pin 17
Pin 18
Pin 19
Pin 20
Pin 21
Pin 22
Pin 23
Pin 24
Pin 25
Pin 26
Pin 27
Pin 28
Pin 29
Pin 30
Pin 31
Pin 32
Pin 33
Pin 34
Pin 35
Pin 36
Pin 37
white/green Output D10
brown/green Output D11
white/yellow Output D12
yellow/brown Output D13
white/grey
grey/brown
white/pink
pink/brown
white/black
Output D14
Output D15
Output D16
Output D17
Output D18
UP/DOWN
UP/DOWN counting direction input.
This input is standard on High. UP/DOWN
means ascending output data with clock-
wise shaft rotation when looking at flange.
UP/DOWN-Low means ascending values
with counterclockwise shaft rotation when
looking at flange.
brown/black Output D19
grey/green
yellow/grey
pink/green
yellow/pink
–
Output D20
Output D21
Output D22
Output D23
–
ENABLE
STORE
Input for activating the output drivers that
are triggered by input level Low. Upon
being on High (or less potential) the output
drivers switch to high-impedance (Tristate).
Input for output data storage. Upon a Low
input level the encoder data are stored in
the intermediate memory. Upon being on
High (or less potential) the current encoder
position data are switched to the output
drivers. This line must be applied for
reliable data readout in binary code.
–
–
yellow/blue
brown/blue
brown/red
green/blue
–
Zero setting
ENABLE
STORE
UP/DOWN
–
GND-Sense
UB-Sense
Internally connected to GND and serves
together with UB-Sense for measuring the
encoder voltage supply.
–
–
–
–
Internally connected to UB. In case the
sensor line is not utilized the connection
must be isolated (danger of short circuit).
white/blue
white/red
red
GND-Sense
UB-Sense
UB
blue
GND
www.baumerivo.com
3