Safety relay
OA / OW 5669
• according to EN 50 205, IEC/EN 60 255,
IEC 60 664-1
• with positively driven contacts
• wash proof model as option
• double and reinforced insultaion between
contact sets according to EN 50 178
• low rated power consumption
• high mechanical service life
• compact size, small height
• Approvals: UL, CSA,
TÜV approval: R 9012316
Applications:
ZH1/457 press controls
Switchgear for safety technology
OA / OW 5669
Technical data
Relay type
OA 5669
1. 0 Relay coil
1. 1 Nominal voltage
1. 2 Nominal consumption
DC V
W
5, 6, 12, 20, 24, 48, 60, 110
0,7
2. 0 Contacts
2. 1 Contact arrangement
1 NC / 1NO
2 changeover contacts, 1 No and 1 changeover contact
AgCdO + 0,2 µm Au; AgNi 10 + 0,2 µm Au optionally + 5 µm Au
250
2. 2 Contact material
2. 3 Rated insulation voltage
Switching voltage min./max.
2. 4 Limiting continuous current
Switching current min./max.
2. 5 Switching power min./max.
Switching power min./max.
2. 6 Switching capacity
to IEC/EN 60 947-5-1 AC 15
DC 13
AC V
V
A
A
VA
W
AC/DC 10 / DC 250, AC 400 (AC/DC 100 mV / 60 V)1)
2 x 5 (see operating voltage limit curve)
10mA3) / 8 (1 mA / 0,3 A)1)
3 / 2 000 (1 mVA / 7 VA)1)
3 / 200 (1 mW / 7 W) 1) (s. limit curve for arc-free operation)
AC V/A
DC V/A
NC: 230 / 1
NC: 24 / 2
NO: 230 / 3
NO: 24 / 2
2. 7 Electrical life 2)
AC 230 V 6 A cos ϕ = 1
2. 8 Switching frequency max. switching cycles / s
at 1 s On, 1 s Off
> 1 x 105 AgNi 10
10
(s. contacts service life)
switching cycles
> 2 x 105 AgCdO
2. 9 Response time / Release time
2.10 Contact force NO / NC
ms
cN
≤ 15 / ≤ 12
≥ 10 / ≥ 8
3. 0 Other
3. 1 Mechanical life
switching cycles
≥ 50 x 106
3. 2 Temperature range
°C
- 40 ... + 60 mounted without distance (Ith = 2 x 5 A)
3. 3 Degree of protection, housing
3. 4 Housing
IP40 / IP67 IEC/EN 60 529 wash proof
Thermoplast GF, PA
3. 5 Vibration resistance
10 ... 55 Hz; 0,35 mm amplitude; 5 g max. IEC/EN 60 068-2-6
3. 6 Climate resistance
40 / 060 / 04 (climate category); A/B/D IEC/EN 60 068-1
3. 8 Insolation according to IEC 60 664-1, EN 50 178
doubleandreinforcedinsulation
Rated insulation voltage
Contamination level
Overvoltage category
AC V
250
2
III
1) Values for AgNi 10-contacts + 5 µm Au
2) 10 A total current at t = 20°C and coil voltage UN
3) Typical values
All technical data in this list relate to the state at the moment of edition.
We reserve the right for technical improvements and changes at any time.
OA/ OW 5669 / 25.02.03 d