IXGH30N60B
IXGT30N60B
Symbol
gfs
TestConditions
CharacteristicValues
(TJ = 25°C, unless otherwise specified)
min. typ. max.
TO-247 AD (IXGH) Outline
IC = IC110; VCE = 10 V,
25
S
Pulse test, t £ 300 ms, duty cycle £ 2 %
Cies
Coes
Cres
2700
190
50
pF
pF
pF
VCE = 25 V, VGE = 0 V, f = 1 MHz
Qg
125
23
150 nC
35 nC
75 nC
Qge
Qgc
IC = IC110, VGE = 15 V, VCE = 0.5 VCES
50
td(on)
tri
td(off)
tfi
Inductive load, TJ = 25°C
25
30
ns
ns
Dim. Millimeter
Inches
Min. Max. Min. Max.
IC = IC110, VGE = 15 V, L = 100 mH,
VCE = 0.8 VCES, RG = Roff = 4.7 W
A
B
19.81 20.32 0.780 0.800
20.80 21.46 0.819 0.845
130
100
1.3
220 ns
190 ns
Remarks: Switching times may
increase for VCE (Clamp) > 0.8 • VCES
higher TJ or increased RG
C
D
15.75 16.26 0.610 0.640
3.55 3.65 0.140 0.144
,
,
Eoff
2
mJ
E
F
4.32 5.49 0.170 0.216
5.4
6.2 0.212 0.244
td(on)
tri
25
35
ns
ns
Inductive load, TJ = 150°C
G
H
1.65 2.13 0.065 0.084
-
4.5
-
0.177
IC = IC110, VGE = 15 V, L = 100 mH
Eon
td(off)
tfi
0.3
200
290
3
mJ
ns
J
1.0
1.4 0.040 0.055
VCE = 0.8 VCES, RG = Roff = 4.7 W
K
10.8 11.0 0.426 0.433
L
M
4.7
0.4
5.3 0.185 0.209
0.8 0.016 0.031
Remarks: Switching times may
increase for VCE (Clamp) > 0.8 • VCES
higher TJ or increased RG
ns
N
1.5 2.49 0.087 0.102
Eoff
mJ
RthJC
RthCK
0.62 K/W
K/W
0.25
(IXGH30N60B)
IXBH30N60B characteristic curves are located in the IXBH30N60BU1 data sheet.
TO-268AA (D3 PAK)
Dim.
Millimeter
Min. Max.
Inches
Min. Max.
Min. Recommended Footprint
A
A1
A2
4.9
2.7
.02
5.1
2.9
.25
.193 .201
.106 .114
.001 .010
b
b2
C
1.15
1.9
.4
1.45
2.1
.65
.045 .057
.75
.83
.016 .026
D
E
E1
13.80 14.00
15.85 16.05
.543 .551
.624 .632
.524 .535
13.3
5.45 BSC
18.70 19.10
13.6
e
H
L
.215 BSC
.736 .752
.094 .106
2.40
2.70
L1
L2
L3
L4
1.20
1.00
0.25 BSC
1.40
1.15
.047 .055
.039 .045
.010 BSC
3.80
4.10
.150 .161
IXYS MOSFETS and IGBTs are covered by one or more of the following U.S. patents:
© 2000 IXYS All rights reserved
2 - 2
4,835,592
4,850,072
4,881,106
4,931,844
5,017,508
5,034,796
5,049,961
5,063,307
5,187,117
5,237,481
5,486,715
5,381,025