MY4ZN1-D2

型号:

MY4ZN1-D2

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

12 页

PDF大小:

249 K

9
General-purpose Relay  
MY  
Versatile, Multi-featured, Two-and  
Four-Pole Miniature Power Relays  
for Sequence Control and Power  
Switching Applications  
1 Increased reliability through automated  
production  
1 Multiple features available, including  
LED indicator, test button, bifurcated  
contacts, built-in diode and CR (surge  
suppression)  
1 Max. switching current: two-pole/10 A,  
four-pole/5 A  
1 Environment-friendly cadmium-free  
contacts  
èò  
1 Built-in operation indicator and name-  
plate is standard  
Ordering Information  
3 RELAYS  
Standard Coil Polarity  
Part number  
Type  
Contact form  
-
Plug in socket/Solder terminals  
Standard with LED indicator With LED indicator and test button Without LED indicator  
Standard  
DPDT  
MY2N  
MY2IN  
MY2  
MY4  
MY4Z  
-- -- --  
4PDT  
MY4N  
MY4IN  
4PDT (bifurcated)  
DPDT  
MY4ZN  
MY4ZIN  
With built-in diode  
(DC only)  
MY2IN-D2  
MY4IN-D2  
MY4ZIN-D2  
MY2IN-CR  
MY4IN-CR  
MY4ZIN-CR  
MY2N-D2  
MY4N-D2  
MY4ZN-D2  
MY2N-CR  
MY4N-CR  
MY4ZN-CR  
4PDT  
-- -- --  
4PDT (bifurcated)  
DPDT  
-- -- --  
With built-in CR  
(220/240 VAC,  
110/120 VAC only)  
-- -- --  
4PDT  
-- -- --  
4PDT (bifurcated)  
-- -- --  
Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.  
Example: MY2 AC6(S)  
Rated coil voltage  
2. Arc barrier standard on all four-pole relays.  
3. Other models also available, such as, three-pole versions, flangemount, PCB, etc. Contact your Omron Representative for  
details.  
MY  
MY  
Ordering Information -- continued from previous page  
Reverse Coil Polarity  
Part number  
Type  
Contact form  
Plug--in socket/Solder terminals  
With LED indicator  
MY2N1  
With LED indicator and test button  
Standard (DC only)  
DPDT  
MY2IN1  
4PDT  
MY4N1  
MY4IN1  
4PDT (bifurcated)  
DPDT  
MY4ZN1  
MY4ZIN1  
With built--in diode  
(DC only)  
MY2N1--D2  
MY2IN1--D2  
MY4IN1--D2  
MY4ZIN1--D2  
4PDT  
MY4N1--D2  
4PDT (bifurcated)  
MY4ZN1--D2  
Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.  
Example: MY2 AC6(S)  
Rated coil voltage  
2. Arc barrier standard on all four--pole relays.  
Specifications  
3 COIL RATINGS  
Rated current  
Inductance (reference  
value)  
Must  
Must  
Max.  
Rated voltage  
Coil  
resistance  
Power  
consump--  
operate release voltage  
tion  
(approx.)  
50 Hz  
60 Hz  
Arm. OFF  
Arm. ON  
% of rated voltage  
AC  
80%  
max.  
30%  
min.  
110%  
1.0 to  
1.2 VA  
(60 Hz)  
6 V*  
214.1 mA  
106.5 mA  
53.8 mA  
25.7 mA  
183 mA  
91 mA  
46 mA  
22 mA  
12.2  
46 Ω  
0.04 H  
0.17 H  
0.69 H  
3.22 H  
19.20 H  
0.08 H  
0.33 H  
1.30 H  
5.66 H  
32.1 H  
12 V  
24 V  
180 Ω  
788 Ω  
48 V*  
110/120 V  
0.9 to  
9.9/10.8 mA 8.4/9.2 mA 4,430 Ω  
1.1 VA  
(60 Hz)  
220/240 V  
4.8/5.3 mA  
4.2/4.6 mA 18,790 Ω  
83.50 H  
136.4 H  
DC  
10%  
min.  
0.9 W  
6 V*  
151 mA  
75 mA  
39.8 Ω  
160 Ω  
0.17 H  
0.73 H  
3.20 H  
10.60 H  
45.60 H  
0.33 H  
1.37 H  
5.72 H  
21.0 H  
86.2 H  
12 V  
24 V  
37.7 mA  
18.8 mA  
9.0/9.9 mA  
636 Ω  
48 V*  
100/110 V  
2,560 Ω  
11,100 Ω  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/--20% for rated cur--  
rents and ±15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C.  
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).  
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a  
bleeder resistor if required.  
5. Rated voltage denoted by * will be manufactured upon request. Ask your OMRON representative.  
“ ”  
2
MY  
MY  
3 CONTACT RATINGS  
2 pole  
-
4--pole  
4--pole (bifurcated)  
Item  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4,  
L/R = 7 ms)  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4,  
L/R = 7 ms)  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4,  
L/R = 7 ms)  
Rated load  
5A, 250 VAC  
5A, 30 VDC  
2A, 250 VAC  
2 A, 30 VDC  
3 A, 250 VAC  
3 A, 30 VDC  
0.8 A, 250 VAC  
1.5 A, 30 VDC  
3 A, 250 VAC  
3 A, 30 VDC  
0.8 A, 250 VAC  
1.5 A, 30 VDC  
Carry current  
10 A (See Note.)  
5 A (See Note.)  
Max. switching  
voltage  
250 VAC  
125 VDC  
250 VAC  
125 VDC  
Max. switching  
current  
10 A  
5 A  
Max. switching  
capacity  
2,500 VA  
300 W  
1,250 VA  
300 W  
1,250 VA  
150 W  
500 VA  
150 W  
1,250 VA  
150 W  
500 VA  
150 W  
Note: Do not exceed the carry current of a Socket in use.  
3 CHARACTERISTICS  
Contact resistance  
Operate time  
100 mmax.  
20 ms max.  
Release time  
20 ms max.  
Max. operating  
frequency  
Mechanical  
Electrical  
18,000 operations/hr  
1,800 operations/hr (under rated load)  
Insulation resistance  
1,000 Mmin. (at 500 VDC)  
Dielectric withstand voltage  
Vibration resistance  
2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)  
Destruction: 10 to 55 Hz, 1.0 mm double amplitude  
Malfunction: 10 to 55 Hz, 1.0 mm double amplitude  
2
Shock resistance  
Destruction: 1,000 m/s (approx. 100G)  
2
Malfunction: 200 m/s (approx. 20G)  
Life expectancy  
See the following table.  
Ambient  
Operating  
-- 5 5 °C to 70°C (--67°F to 158°F) with no icing (See Note.)  
temperature  
Ambient humidity Operating  
Weight  
35% to 85%  
Approx. 35 g  
Note: The values given above are initial values.  
3 LIFE EXPECTANCY CHARACTERISTICS  
Pole  
Mechanical life (at 18,000 operations/hr) Electrical life (at 1,800 operations/hr under rated load)  
AC: 50,000,000 operations min.  
DC: 100,000,000 operations min.  
2--pole  
500,000 operations min.  
200,000 operations min.  
100,000 operations min.  
4--pole  
4--pole (bifurcated)  
20,000,000 operations min.  
3 APPROVED STANDARDS  
VDE, UL, CSA, IMQ, CE  
3
MY  
MY  
Engineering Data  
3 MAXIMUM SWITCHING CAPACITY  
MY2  
MY4, MY4Z  
oad  
oad  
Switching voltage (V)  
Switching voltage (V)  
3 LIFE EXPECTANCY  
MY2 (Resistive Loads)  
MY2 (Inductive Loads)  
Switching current (A)  
Switching current (A)  
MY4 (Resistive Loads)  
MY4 (Inductive Loads)  
Switching current (A)  
Switching current (A)  
4
MY  
MY  
MY4Z (Inductive Loads)  
MY4Z (Resistive Loads)  
30 VDC  
30 VDC  
250 VAC  
250 VAC  
Switching current (A)  
Switching current (A)  
Dimensions  
Unit: mm (inch)  
3 2--POLE MODELS  
2.6  
(0.10)  
1.2 x 2.2 long holes  
0.5  
(0.02)  
28 max.  
(1.10)  
36 max.  
(1.42)  
23.5 max.  
(0.93)  
6.4  
(0.25)  
3 4--POLE MODELS  
2.6  
(0.10)  
1.2 x 2.2 long holes  
0.5  
(0.02)  
28 max.  
(1.10)  
36 max.  
(1.42)  
21.5 max.  
(0.85)  
6.4  
(0.25)  
3 MODELS WITH TEST BUTTON  
5
(0.20)  
5
(0.20)  
Test button  
5
(0.20)  
Nameplate  
36 max.  
(1.42)  
5
MY  
MY  
3 TERMINAL ARRANGEMENT/INTERNAL CONNECTIONS (BOTTOM VIEW)  
MY2  
MY2N/MY2IN  
(AC Models)  
MY2N/MY2IN  
(DC Models)  
MY2N--D2/MY2IN--D2  
(DC Models Only)  
MY2N--CR/MY2IN--CR  
(AC Models Only)  
MY2N1/MY2IN1  
(DC Models Only)  
MY2N1--D2/MY2IN1--D2  
(DC Models Only)  
MY4(Z)  
MY4(Z)N/MY4(Z)IN  
(AC Models)  
MY4(Z)N/MY4(Z)IN  
(DC Models)  
MY4(Z)N--D/MY4(Z)IN--D2  
(DC Models Only)  
MY4(Z)N--CR/MY4(Z)IN--CR  
(AC Models Only)  
MY4(Z)N1/MY4(Z)IN1  
(DC Models Only)  
MY4(Z)N1--D2/MY4(Z)IN1--D2  
(DC Models Only)  
6
MY  
MY  
Accessories (order separately)  
3 SOCKETS  
Back-mounting Socket  
Poles  
Front--mounting  
Socket (DIN-  
track/screw  
mounting)  
PCB terminals  
Solder terminals  
Without clip  
PY08  
With clip  
PY08-Y1  
PY14-Y1  
2
4
PYF08A-E  
PYF14A-E  
PY08-02  
PY14-02  
PY14  
3 SOCKET HOLD--DOWN CLIP PAIRING  
Back-connecting Socket  
Relay type  
Poles  
Front-connecting Socket  
(DIN-track/screw mounting)  
Solder terminals  
Socket  
PCB terminals  
Socket  
Socket  
Clip  
Clip  
Clip  
Without 2-pole  
test button  
PYC-A1  
PYC-P  
PYC-P2  
PYC-P  
PYC-P2  
2
4
2
PYF08A-E  
PYF14A-E  
PYF08A-E  
PY08  
PY08-02  
PY14-02  
PY08-02  
PY14  
2-pole test  
button  
PYC-E1  
PY08  
PYC-P2  
PYC-P2  
3 MOUNTING PLATES FOR SOCKETS  
Socket model  
PY08, PY14  
For 1 Socket  
PYP-1  
For 18 Sockets  
PYP-18  
For 36 Sockets  
PYP-36  
Note: PYP--18 and PYP--36 can be cut into any desired length in accordance with the number of Sockets.  
3 DIN RAIL TRACK AND ACCESSORIES  
Description  
Part number  
PFP-50N  
Mounting Rail (length = 500 mm)  
Mounting Rail (length = 1,000 mm)  
End Plate  
PFP-100N, PFP-100N2  
PFP-M  
Spacer  
PFP-S  
7
MY  
MY  
Dimensions  
Unit: mm (inch)  
Socket  
Dimensions  
Terminal  
arrangement/Internal  
Mounting holes  
connections (top view)  
Two, M3, M4, or 4.5--dia holes  
PYF08A--E  
Two, 4.2 x 5  
mounting  
holes  
Eight, M3 x 8  
sems screws  
72 max.  
(TOP VIEW)  
23 max.  
Note: Track mounting is also  
possible. Refer to page  
NO TAG for supporting  
tracks.  
31 max.  
Two, 4.2 X 5  
mounting  
holes  
PYF14A--E  
Two, M3, M4, or 4.5--dia holes  
Fourteen, M3 x 8  
sems screws  
72 max.  
(TOP VIEW)  
Note: Track mounting is also  
possible. Refer to page  
NO TAG for supporting  
tracks.  
29.5 max.  
31 max.  
(See note)  
Eight, 3 x 1.2 elliptical holes  
PY08/PY08--Y1  
25.5 max.  
29.5 max.  
20 max.  
24 max.  
42 max.  
Note: ThePY08--Y1includessectionsindicatedby  
dotted lines.  
PY08--02  
25.5 max.  
29.5 max.  
22 max.  
Eight, 1.3--dia  
holes  
16.5 max.  
8
MY  
MY  
Socket  
Dimensions  
Terminal  
arrangement/Internal  
Mounting holes  
connections (top view)  
(See note)  
Fourteen, 3 x 1.2 elliptical holes  
25.5 max.  
PY14/PY14--Y1  
29.5 max.  
24 max.  
20 max.  
42 max.  
Note: ThePY14--Y1includessectionsindicatedby  
dotted lines.  
PY14--02  
25.5 max.  
29.5 max.  
22 max.  
16.5 max.  
Fourteen,  
1.3--dia holes  
Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.  
3 HOLD--DOWN CLIPS  
PYC--A1  
PYC--E1  
36.3  
4.5  
36.3  
4.25  
5.75  
±
0.1  
1.2  
4.5  
4.5  
PYC--P  
PYC--P2  
5
10  
28  
3.3  
38.5  
9
MY  
MY  
3 MOUNTING PLATES FOR BACK--CONNECTING SOCKETS  
PYP--36  
PYP--1  
Two, 3.4--dia holes  
72 elliptical holes  
PYP--18  
72 elliptical holes  
3 MOUNTING TRACK AND ACCESSORIES  
Din rail track  
PFP--50N/PFP--100N  
4.5  
7.3±0.15  
35±0.3  
27±0.15  
15 (5)  
15  
25  
25  
25  
25  
1
10  
10  
1000 (500) *  
Note: The figure in the parentheses is for PFP--50N.  
PFP--100N2  
16  
4.5  
29.2  
35±0.3  
27 24  
15 25  
25  
25 15  
10  
25  
1
1.5  
10  
1000  
End plate  
10  
M4 x 8 pan head screw  
6.2  
1
1.8  
35.3  
35.5  
50  
11.5  
1.8  
1.3  
4.8  
10  
M4 spring washer  
10  
MY  
MY  
Spacer  
16  
12  
5
34.8  
44.3  
16.5  
3 APPROVALS  
UL recognized type (File no. E41515)  
Type  
Contact form  
DPDT  
Coil ratings  
Contact ratings  
MY  
6 to 240 VAC, 6 to 120 VDC 5 A, 120 VAC (resistive)  
5 A, 28 VDC (resistive)  
5 A, 240 VAC (inductive)  
3PDT  
4PDT  
5 A, 28 VDC (resistive)  
5 A, 240 VAC (resistive)  
3 A, 28 VDC (resistive)  
3 A, 120 VAC (inductive)  
1.5 A, 240 VAC (inductive)  
5 A, 240 VAC (inductive, same polarity)  
5 A, 28 VDC (resistive, same polarity)  
3 A, 240 VAC (resistive)  
MY2K--†  
DPDT  
5 to 120 VAC, 5 to 48 VDC  
3 A, 28 VDC (resistive)  
CSA certified type (File no. LR31928)  
Type  
Contact form  
DPDT, 3PDT  
Coil ratings  
Contact ratings  
MY†  
6 to 240 VAC, 6 to 120 VDC 5 A, 28 VDC (resistive)  
5 A, 240 VAC (inductive)  
4PDT  
3 A, 28 VDC (resistive)  
3 A, 240 VAC (inductive)  
5 A, 240 VAC (inductive, same polarity)  
5 A, 28 VDC (resistive, same polarity)  
3 A, 240 VAC (general purpose)  
3 A, 28 VDC (resistive)  
MY2K--†  
DPDT  
5 to 120 VAC, 5 to 48 VDC  
LR (Loyd s register) approved type (File no. 563KOB--204524)  
Type  
Contact form  
DPDT  
Coil ratings  
Contact ratings  
MY†  
6 to 240 VAC, 6 to 120 VDC 2 A, 30 VDC (inductive)  
2 A, 200 VAC (inductive)  
4PDT  
1.5 A, 30 VDC (inductive)  
0.8 A, 200 VAC (inductive)  
1.5 A, 115 VAC (inductive)  
11  
MY  
MY  
SEV listed type (File no. D791/63 [2 & 4--pole], D791/91 [3--pole])  
Type  
Contact form  
DPDT  
Coil ratings  
Contact ratings  
MY-- S V  
6 to 240 VAC, 6 to 110 VDC  
5 A, 220 VAC (resistive)  
5 A, 24 VDC (resistive)  
3PDT  
4PDT  
Note: 1. The rated values approved by each of the safety standards (eg., UL, CSA, VDE, and SEV) may be different from the  
performance characteristics individually defined in this catalog.  
2. In the interest of product improvement, specifications are subject to change.  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
9
OMRON ELECTRONICS, INC.  
OMRON CANADA, INC.  
One East Commerce Drive  
885 Milner Avenue  
Schaumburg, IL 60173  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC RLY7  
01/00  
Specifications subject to change without notice.  
Printed in U.S.A.  
厂商 型号 描述 页数 下载

OMRON

MY4 通用继电器[ General-purpose Relay ] 20 页

OMRON

MY4 AC12 (S) [ RELAY GEN PURPOSE 4PDT 3A 12V ] 35 页

OMRON

MY4 AC24 (S) [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

OMRON

MY4 AC6 (S) [ RELAY GENERAL PURPOSE 4PDT 3A 6V ] 35 页

OMRON

MY4 DC12 (S) [ RELAY GEN PURPOSE 4PDT 3A 12V ] 35 页

OMRON

MY4 DC24 (S) [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

OMRON

MY4 DC6 (S) [ RELAY GENERAL PURPOSE 4PDT 3A 6V ] 35 页

OMRON

MY4-02-AC24 [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

OMRON

MY4-02-DC12 [ RELAY GEN PURPOSE 4PDT 3A 12V ] 35 页

OMRON

MY4-02-DC24 [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.213490s