Performance Specifications
Supply Voltage (Vs)
Parameter
Min
11.4
Typical
12.0
Max
12.6
Unit
VDC
Condition
Supply Voltage
4.5
1.8
Watts
Watts
during warm-up
steady state @ +25°C
Power Consumption
Reference Voltage
9.8
+9.0
1.5
10
10.2
VDC
RF Output
Sinewave
Signal
Load
50
Ohms
dBm
dBc
Output Power
Harmonics
Spurious
+13.0
-30
50 Ohm load
50 Ohm load
50 Ohm load
-80
dBc
Frequency Tuning (EFC)
Tuning Range
3.0
20
ppm
Linearity
ꢀ
Tuning Slope
Positive
Control Voltage Range
Input Impedance
Modulation Bandwidth
0
10
VDC
kOhm
Hz
20
150
Additional Parameters
g- Sensitivity
Weight
1
ppb/g
grams
worst axis
20
Absolute Maximum Ratings
Parameter
Supply Voltage (Vs)
Output Load
Min
Typical
Max
15
Unit
V
Condition
25
Ohms
Device will not sustain damage when
operated at temperatures between the
operating range and the operable range,
but will not be specification compliant.
Operable Temperature Range
-55
+95
°C
Environmental and Product Classification
MIL-STD-202, Method 213, Condition J, 30 g 11 ms
Shock (Endurance)
Sine Vibration (Endurance)
Random Vibration (Endurance)
Humidity
MIL-STD-202, Method 201 and 204, Condition A, except 5 g to 500 Hz, 1 sweep each axis
MIL-STD-202, Method 214, Condition I-D
MIL-STD-202, Method 103, Condition B, 100ꢀ rh
MIL-STD-202, Method 112, Condition D
Seal
Altitude
MIL-STD-202, Method 105, sea level to30,000 ft
MIL-STD-202, Method 210, Condition A,B,C
MIL-STD-202, Method 11, Condition C (5 bends at 45o, 2 lbs)
1
Resistance to Soldering Heat
Terminal Strength
Moisture Sensitive Level
6 (fully compliant) - no pure tin options available upon request, the device will be assigned a
customer part number , not orderable through ordering codes
RoHS
Storage Temperature Range
-55
+125
°C
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com