DC-DC Converter
JVA15 Series
15 Watts
• Renewable Energy, Industrial Applications and EV Applications
xxx Series
• Ultrawide Input Range - 200-1500 VDC
• Fully Encapsulated PCB Mount & DIN Rail Versions
• Optional DIN Rail Versions with Built In EMI Filter & 1500 VDC Fuse
• -40 °C to +70 °C Operating Temperature
• 3 Year Warranty
The JVA series offers high isolation DC-DC converters with an ultra wide DC
input range. Configuration options provide convenient installation choices.
Dimensions:
JVA15: 4.92 x 2.95 x 1.57” (124.9 x 74.9 x 40.0 mm)
JVA15-D: 5.08 x 4.02 x 1.92” (129.0 x 102.0 x 49.0 mm)
JVA15-DF: 5.75 x 5.43 x 2.17” (146.05 x 137.9 x 55.0 mm)
Models & Ratings
Output
Voltage
Overvoltage
Protection (typical)
Typical
Maximum
Capacitive Load
Output Power Input Voltage
Output Current Input Current(1)
Model Number(2,3)
Efficiency(4)
10 W
5.0 V
12.0 V
15.0 V
24.0 V
8.0 V
20.0 V
20.0 V
30.0 V
2000 mA
64%
71%
72%
74%
6000 µF
2000 µF
1200 µF
470 µF
JVA151500S05
JVA151500S12
JVA151500S15
JVA151500S24
1250 mA
120 mA
200-1500 V
15 W
1000 mA
625 mA
Notes
1. At 200 VDC input
2. For DIN rail mount option, add suffix '-D' e.g. JVA151500S12-D
3. For DIN rail with added EMI filter option, add suffix '-DF' e.g. JVA151500S24-DF
4. At 800 VDC Input
Input
Minimum
Typical
Maximum
Units
VDC
mA
A
Notes & Con
ditions
Characteristic
Input Voltage Range
Input Current
1500
See derating curve
200
200 VDC/80
200 VDC/15
0 VDC/1500 VDC input
120/
/150
30/16
00 VDC input
Inrush Current
50
Input Filter
Pi type
Undervoltage Lockout
Input Protection
On 180-195 V, Off 170-18
External 15 A/1500 VDC
5 V
This is alrea
dy included in the optional -DF version
required
Output
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Output Voltage
5
24
V
See Models and Ratings table
Initial Set Accuracy
Minimum Load
2
%
0
A
No minimum load required
Start Up Delay
2
1
1
s
%
Line Regulation
Load Regulation
Ripple & Noise
%
0 - 100% load
150
300
320
mV pk-pk
20 MHz bandwidth
Short Circuit Protection
Overload Protection
Overvoltage Protection
Temperature Coefficient
Trip & Restart (hiccup mode), auto recovery
Trip & Restart (hiccup mode)
See Models and Ratings table
120
%
0.02
%/˚C
www.xppower.com
1