Technical Data Sheet  
Calibration Kit  
RPC-2.40  
09CK010-150  
Industrial Version  
Contents  
Device  
Part number  
Quantity  
Calibration Optiona  
Open circuit plug  
09S12L-000S3  
09K12L-000S3  
09S12S-000S3  
09K12S-000S3  
09S150-C10S3  
09K150-C10S3  
09S121-S20S3  
09K121-K20S3  
03W008-000  
1
1
1
1
1
1
1
1
1
1
FC  
FC  
FC  
FC  
FC  
FC  
FC  
FC  
-
Open circuit jack  
Short circuit plug  
Short circuit jack  
Calibration load plug  
Calibration load jack  
Calibration adaptor plug/plug  
Calibration adaptor jack/jack  
Combi wrench  
Torque wrench  
03W021-000  
FC  
a.  
See “Declaration of calibration options” for explanation.  
Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260 D-84526 Tittmoning Germany  
www.rosenberger.de  
Tel. : +49 8684 18-0  
Fax : +49 8684 18-499  
Email : info@rosenberger.de  
Page  
1 / 3  
Technical Data Sheet  
Calibration Kit  
RPC-2.40  
09CK010-150  
Industrial Version  
Documentation  
This kit is delivered with  
USB-Stick  
Standard Definitions as data files for Vector Network Anaylzer Families PNA (Keysight/Agilent) and ZVA  
(Rohde&Schwarz). Calibration Certificate as PDF-file.  
Standard Definitions Cards  
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.  
Kit Info Card  
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.  
Calibration Certificate  
Details see “Declaration of calibration options”  
Operating Manual  
Electrical specifications  
This specification covers electrical key values for the main calibration standards of the calibration kit.  
Specific datasheets are available for each component among the part number.  
Calibration standard  
Frequency  
Parameter  
Specification  
4 GHz  
26.5 GHz  
50 GHz  
2.0°  
4.0°  
6.0°  
DC  
> 4 GHz  
> 26.5 GHz to  
to  
to  
Opensb  
(plug and jack)  
Error from  
Nominal Phase  
4 GHz  
26.5 GHz  
50 GHz  
1.5°  
3.0°  
4.5°  
DC  
> 4 GHz  
> 26.5 GHz to  
to  
to  
Shortsb  
(plug and jack)  
Error from  
Nominal Phase  
4 GHz  
26.5 GHz  
50 GHz  
36 dB  
30 dB  
22 dB  
DC  
> 4 GHz  
> 26.5 GHz to  
to  
to  
Calibration loads  
Return Loss  
Return Loss  
(plug and jack)  
4 GHz  
26.5 GHz  
50 GHz  
30 dB  
24 dB  
17 dB  
DC  
> 4 GHz  
> 26.5 GHz to  
to  
to  
Calibration adaptors  
(plug/plug and jack/jack)  
b.  
The specifications for opens and shorts are given as allowed deviation from nominal model as defined in calibration certificate  
included with your kit.  
Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260 D-84526 Tittmoning Germany  
www.rosenberger.de  
Tel. : +49 8684 18-0  
Fax : +49 8684 18-499  
Email : info@rosenberger.de  
Page  
2 / 3  
Technical Data Sheet  
Calibration Kit  
RPC-2.40  
09CK010-150  
Industrial Version  
Declaration of calibration options  
Factory Calibration  
Standard delivery for this kit includes a Factory Calibration. All devices marked with “FC” in the Content table  
above are reported in a Calibration Certificate with their individual calibration results, traceable to national /  
international standards. Model based definitions of the calibration standards are reported in Agilent/Keysight,  
Rohde & Schwarz and Anritsu compatible VNA format.  
Accredited Calibration  
Not available.  
For further, more detailed information see application note AN001 on the Rosenberger homepage.  
Calibration interval  
Recommendation  
12 months  
Recommended accessories  
- Rosenberger Test Port Adaptor  
- Rosenberger Gauge Kit 08GK0KS-010  
- Rosenberger VNA Test cable kit and Microwave Cable Assemblies  
For further, more detailed information please visit our homepage www.rosenberger.com.  
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on  
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our  
products, we reserve the right to make changes judged to be necessary.  
Draft  
Date  
Approved  
Date  
Rev.  
a00  
Engineering change number  
15-s152  
Name  
Date  
Martin Moder  
04.03.15  
Herbert Babinger  
09.04.15  
Maik Knoll  
09.04.15  
Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260 D-84526 Tittmoning Germany  
www.rosenberger.de  
Tel. : +49 8684 18-0  
Fax : +49 8684 18-499  
Email : info@rosenberger.de  
Page  
3 / 3  
厂商 型号 描述 页数 下载

ROSENBERGER

09K121-K20S3 [ Calibration Kit ] 3 页

ROSENBERGER

09K12L-000S3 [ Calibration Kit ] 3 页

JST

09KR-6H-P [ 2.0mm pitch/Disconnectable Insulation displacement and Crimp style connectors ] 8 页

JST

09KR-6H-PC [ 2.0mm pitch/Disconnectable Insulation displacement and Crimp style connectors ] 8 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.199681s