XW2Z-0500U-5

型号:

XW2Z-0500U-5

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

8 页

PDF大小:

352 K

FA Wireless SS Terminals  
WT30  
Construct a Wireless System for ON/OFF  
Data Collection That Is Ideal for Monitoring  
Production Site Equipment  
• Wireless Slave Station equipped with I/O.  
• Height of 90 mm and DIN Rail mounting enables installation in  
control panels.  
• Easily check wireless communications status from indicator  
display.  
• I/O Slave Stations can also be used as Slave Stations in WD30  
systems.  
• Conforms to radio wave standards for Japan, China (pending),  
USA, and Europe.  
Ordering Information  
List of Models  
Wireless Unit model  
Type  
Specifications/No. of I/O points  
WT30-M01-FLK  
Serial master  
I/O slaves  
RS-232C  
WT30-SID16  
16 DC inputs (NPN/PNP)  
WT30-SMD16  
WT30-SMD16-1  
8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN)  
8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP)  
Note: An Antenna and Mounting Brackets are not included with the Wireless SS Terminal.  
Accessories  
Antennas  
Applicable Standards  
FCC part 15.247 (USA)  
EN 300 440-2 (Europe)  
ARIB STD-T66 (Japan)  
Model  
WT30-AT001  
WT30-AT002  
WT30-AT003  
Type  
Magnet-base Antenna (2 antennas per set)  
Flat Diversity Antenna (1 antenna)  
Pencil Antenna (2 antennas per set)  
(China) (approval pending)  
Communications Cables  
Conformity to Safety Standards  
Always use a Class 2 power supply to conform to UL standards.  
Model  
Length  
Application  
XW2Z-0100U-3  
XW2Z-0200U-3  
XW2Z-0500U-3  
XW2Z-0200U-5  
XW2Z-0500U-5  
1 m  
2 m  
5 m  
2 m  
5 m  
For personal computer  
Main Class 2 Power Supplies  
OMRON Switching Power Supplies  
S8VS (15 W, 30 W, 60 W type)  
S82K (15 W, 30 W, 50 W, 90 W type)  
Cross cable for PLC  
Conformity to EN Standards  
Use a DC power line less than 3 m to conform to EN standards. If a  
power line of 3 m or longer is required, extend the length at the  
Switching Power Supply’s primary side (i.e., the AC power line).  
Other  
Model  
WT30-FT001  
WT30-FT002  
WT30-FT003  
Type  
DIN Rail Mounting Bracket (for TH35-7.5)  
DIN Rail Mounting Bracket (for TH35-15)  
Applicable Countries  
Wireless standards have been met for the following countries. The  
product cannot be used in any other countries.  
Surface Mounting Bracket (screw-mounting)  
(2 brackets per set)  
WT30-FT011  
WT30-CA2M  
Flat Diversity Antenna Mounting Brackets  
(with magnets)  
Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia,  
Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy,  
Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,  
Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland,  
UK, USA  
Antenna Extension Cable (1 cable, 2 m)  
FA Wireless SS Terminals WT30  
1
Specifications  
Ratings  
Item  
WT30-M01-FLK Serial Master  
24 V DC  
20.4 to 26.4 V DC  
WT30-SID16/SMD16/SMD16-1 I/O Slaves  
Power supply  
(wireless  
communications  
power supply)  
Rated voltage  
Allowable voltage  
range  
Power consumption 3 W max. (See note 1.)  
Error output/output  
power supply  
(for output circuits)  
Rated voltage  
---  
---  
24 V DC  
Allowable voltage  
range  
20.4 to 26.4 V DC  
Insulation resistance  
Dielectric strength  
Noise immunity  
20 Mmin. (at 100 V DC) between the power 20 Mmin. (at 100 V DC) between the power  
supply and chassis  
supply and all I/O and I/O power supply and  
between the power supply and chassis  
1,500 V AC for 1 min between power supply  
and chassis  
1,500 V AC for 1 min between the power supply  
and all I/O and I/O power supply and between  
the power supply and chassis  
IEC61000-4-4. 1 kV (power supply line)  
JIS C0040  
Vibration resistance (See note 2.)  
Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of 50 m/s2, whichever is smaller  
(DIN Rail mounting: single amplitude of 0.1 mm or acceleration of 15 m/s2)  
10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions  
Conforms to JIS C0041: 300 m/s2 3 times each in X, Y, and Z directions  
Shock resistance  
Ambient operating temperature  
10 to 55°C (with no condensation or icing)  
Number of simultaneously ON I/O points  
(with the Terminal mounted with the dust-proof 10 max.: 10 to 55°C (with no condensation or  
label facing up)  
icing)  
16 max.: 10 to 50°C (with no condensation or  
icing)  
(with the Terminal mounted with the dust-proof  
label facing up)  
Ambient operating humidity  
Ambient environment  
Storage temperature  
Protective structure  
25% to 85% (with no condensation or icing)  
No corrosive gases  
25 to 65°C (with no condensation or icing)  
IP20  
Terminal construction Power supply and I/O Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent)  
Serial  
D-sub, 9-pin (female) Inch screws (OMRON  
XM2F-0910-132 or equivalent), Master station  
only  
---  
Safety standards  
Weight  
UL: UL508 (Listing)  
330 g max.  
Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup.  
2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration.  
Wireless Interface Specifications  
Item  
Specifications  
Spread Spectrum (direct sequence; DS-SS)  
Wave type  
Communication method  
Simplex  
Frequency band  
2,401 to 2,480.2 MHz  
67 channels (based on switching)  
10 mW/MHz  
Number of channels  
Transmitter output power  
Baud rate between wireless stations  
Communications distance (See note.)  
100 kbps  
Indoors: 60 m min. (approx. 50 m min. with Magnet-base Antennas and Flat Diversity Antennas)  
Outdoors: Approx. 300 m min. (anticipated distances)  
(without using relay stations)  
Error detection method  
CRC-CCITT (16 bits)  
Relay functions  
One stage using I/O slave for the serial master configuration.  
10 sets max. (recommended)  
64 max.  
Number of stations per area (See note.)  
Number of I/O Slaves connected  
Note: Varies according to the installation environment.  
Package Contents  
WT30 FA Wireless SS Terminal Terminal labels (I/O Slaves only)  
Instruction Sheet  
Adhesive non-slip feet (Serial Master only)  
2
FA Wireless SS Terminals WT30  
Nomenclature  
Serial Master Station  
Unit No. Switch  
Set the unit number of the Serial Master Station  
Unit No. switch  
Set the unit number of the Serial Master Station.  
Default: 00  
Node setting switch (WNODE)  
Set the number of connected I/O Slave Stations.  
Channel setting switch (WCH)  
Set the communications frequency  
channel.  
Node Setting Switch (WNODE)  
Set the number of connected I/O Slave Stations.  
Set the node number of the Slave Stations being used as I/O Slave  
Stations. The Slave Station functions as a relay station when the  
node number is set to 99.  
Antenna terminal (ANT1)  
Antenna terminal (ANT2)  
Default: 01  
Status  
indicators  
Received  
signal  
strength  
indicator  
Channel Setting Switch (WCH)  
Set the communications frequency.  
Special  
function  
switch  
Default: 02  
Function Setting Switch  
Serial Master Station  
No. Applicable  
mode  
ON functions  
OFF functions  
Mode selection switch  
Switch between RUN,  
TEST, and SET mode.  
Function setting switch  
Make the detailed settings  
for RUN/TEST/SET mode.  
1
RUN mode Holds I/O status data Clears I/O status data  
when a when a  
communications error communications error  
RS-232C Terminal  
Connect the PLC, personal computer, etc.  
Power supply terminal  
Supply power to the WT30.  
occurs.  
occurs.  
2
3
4
Enable scan list  
Relays used  
Disable scan list  
Relays not used  
Serial communications  
setting switch  
Set the baud rate.  
TEST mode Signal strength monitor Signal strength monitor  
disabled  
enabled  
I/O Slave Station  
5
All channels  
automatically switched  
Specified channels  
Node setting switch (WNODE)  
6
7
8
---  
---  
Set the unit number of the I/O Slave Station.  
SET mode Scan list recognition  
Nothing done  
I/O terminal status indicators (0 to 7 or 8 to 15)  
The contact status is displayed.  
Registers specified I/O Registers all I/O slaves  
slave  
Channel setting switch (WCH)  
Set the communications frequency.  
automatically  
Antenna terminal (ANT1)  
9
Recognizes serial  
numbers  
Ignores serial numbers  
Antenna terminal (ANT2)  
10  
Not used  
---  
---  
I/O Slave Station  
Status  
indicators  
Received  
signal  
strength  
indicator  
No. Applicable  
mode  
ON functions  
OFF functions  
1
RUN mode Holds I/O status data Clears I/O status data  
when a when a  
communications error communications error  
occurs.  
occurs.  
2
3
4
Input hold  
Normal mode  
Input filter: 10 ms  
Input filter: 100 ms  
TEST mode Signalstrengthmonitor Signalstrength monitor  
disabled  
enabled  
5
6
All channels  
automatically switched  
Specified channels  
Mode selection switch  
Switch between RUN,  
TEST, and SET mode.  
Installation test  
function  
Nothing done  
---  
I/O terminals  
Connect the contact  
signals.  
Special function switch  
7 to Not used  
10  
---  
Function setting switch  
Make the detailed settings  
for RUN/TEST mode.  
Power supply terminal  
Supply power to the WT30  
and output circuits.  
FA Wireless SS Terminals WT30  
3
Serial Communications Setting  
Display  
Switch  
Indicator  
Color Status  
Green Lit  
Not lit  
Meaning (primary error)  
Power is being supplied.  
PWR  
No.  
Function  
ON  
OFF  
Power is not being supplied.  
1
Communications setting Detailed  
selection  
Default settings  
(baud rate: 9,600 bps;  
ERR  
(Slave Station)  
Red  
Lit  
Error output is ON:  
settings  
Wireless device error or  
wireless communications  
error. (See note)  
(settings for data length: 7 bits;  
No. 2 to 8  
used)  
parity: even; stop bits:  
2)  
Settings for No. 2 to 8  
are ignored.  
Not lit  
No wireless device error or  
wireless communications  
error.  
2
3
4
Baud rate (bps)  
(See note.)  
Total value = 0: 1,200  
= 1: 2,400  
1
2
4
0
0
0
COMM  
(Master Station)  
Yellow Lit  
Serial communications in  
progress.  
Not lit  
No serial communications.  
= 2: 4,800  
= 3: 9,600  
0 to 15  
(Slave Station)  
Yellow Lit/Not lit ON/OFF status for input or  
output signals  
RSSI  
Red/  
Lit/  
Receiving Signal Strength  
= 4: 19,200  
= 5: 38,400  
= 6: 57,600  
= 7: 115,200  
Data length  
Parity  
Yellow/ All not lit Indicator monitor: Number of  
Green  
indicators lit (receiving signal  
strength 1 to 9)  
Receiving signal strength less  
than 0 to 1.  
5
6
7
8
8 bits  
None  
Odd  
7 bits  
Yes  
MS  
Green Lit  
Communications are normal.  
(Module Status)  
Flashing TEST mode or SET mode has  
been activated.  
Even  
2 bits  
Stop bits  
1 bit  
Red  
Lit  
A fatal error has occurred that  
cannot be recovered from.  
Replace the Unit  
Note: For example, if pins number 2, 3, and 4 are all ON, the total is  
7, which corresponds to a baud rate of 115,200 bps.  
Flashing A non-fatal error has occurred  
that can be recovered from by  
resetting the system.  
---  
Not lit  
Power is not being supplied or  
the system is resetting.  
WS  
(Wireless  
Status)  
Green Lit  
The station has joined the  
wireless network.  
Flashing Permission to join wireless  
network received from Serial  
Master Station (Slave Station)  
Red  
---  
Lit  
A fatal error has occurred that  
cannot be recovered from.  
Flashing Error from which recovery is  
possible  
Not lit  
Wireless communications are  
not in progress.  
Note: When using the WD30 as the Serial Master Station, the ERR  
indicator will light if normal I/O communications are not  
possible due to an error in the host network.  
4
FA Wireless SS Terminals WT30  
Wiring  
Serial Master Station (WT30-M01-FLK)  
D-sub, 9-pin, Female End at WT30  
Pin No.  
Signal  
---  
I/O direction  
RS-232C Connector  
1
2
3
4
5
6
7
8
9
---  
54321  
RD  
SD  
---  
Output  
Input  
---  
Power supply terminal  
Supply power to the Unit  
WT30  
9876  
SG  
---  
---  
---  
---  
---  
---  
---  
---  
---  
I/O Characteristics  
I/O Slave Station  
WT30-SID16  
Item  
Specifications  
20.4 to 26.4 V DC  
4.7 k(typical)  
Input voltage 24 V DC  
Error output  
power supply  
Error output  
(PNP)  
Allowable  
voltage range  
Inputs  
Inputs  
IN  
V
G
0
1
2
3
COM  
4
5
6
7
COM ERRP  
Input  
impedance  
Input current 5 mA (typical)  
ON voltage/  
current  
characteristics  
17.4 V DC, 3.0 mA min.  
OFF voltage/  
current  
characteristics  
5.0 V DC, 1.0 mA max.  
ERRN  
13 14 15 COM  
24 V DC 0 V  
8
9
10 11 COM 12  
IN  
Input filter  
10 ms/100 ms (Selected using switch.)  
Error output  
(NPN)  
Power supply  
Inputs  
Inputs  
Input voltage 24 V DC  
Allowable  
voltage  
20.4 to 26.4 V DC  
WT30-SMD16  
WT30-SMD-16-1  
Max.  
switching  
current  
100 mA max. per output (at 20.4 to 26.4 V DC)  
Simultaneous usage of error output NPN/PNP  
is not possible.  
Error output/output  
power supply  
Error output  
(PNP)  
Leakage  
current  
0.1 mA max.  
Inputs  
Inputs  
IN  
Residual  
voltage  
1.0 V max.  
V
G
0
1
2
3
COM  
4
5
6
7
COM ERRP  
Fuse  
One for every two outputs except for error  
output circuits, which have one for every NPN/  
PNP output. (No fuses can be replaced by the  
user.)  
24 V DC 0 V  
0
1
2
3
COM  
OUT  
4
5
6
7
COM ERRN  
Error output  
(NPN)  
Power supply Outputs  
Outputs  
FA Wireless SS Terminals WT30  
5
Input Circuit Diagram  
Output Circuit Diagram (NPN)  
V
IN 0  
IN 1  
IN 2  
OUT 0  
OUT 1  
Fuse  
OUT 2  
Fuse  
IN 15  
OUT 7  
COM (IN)  
Fuse  
G
Error Output Circuit Diagram  
Output Circuit Diagram (PNP)  
Fuse  
V
V
OUT 0  
Fuse  
OUT 1  
Fuse  
ERRP  
OUT 2  
OUT 3  
Fuse  
ERRN  
G
OUT 7  
G
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Serial Master Station  
I/O Slave Station  
WT30-M01-FLK  
WT30-SID16  
WT30-SMD16  
WT30-SMD16-1  
105  
105  
120  
13.3  
13.3  
(15)  
90  
60 40  
(15)  
DIN rail mounting bracket  
WT30-FT001 or WT30-FT002  
Surface mounting bracket  
WT30-FT003  
7.3  
6
FA Wireless SS Terminals WT30  
With Magnet-base  
Antenna  
With Flat Diversity  
Antenna  
With Pencil Antenna  
WT30-AT003  
150  
40  
WT30-AT001  
WT30-AT002  
(46)  
(34)  
(23)  
(46)  
R50  
R38  
20  
R40  
(32)  
4.6  
(38)  
Serial Master Station  
Surface Mounting Bracket  
WT30-FT003  
I/O Slave Station  
I/O Slave Station  
DIN Rail mounting bracket  
WT30-FT001 or  
WT30-FT002  
DIN Rail mounting bracket  
WT30-FT001 or  
WT30-FT002  
Magnet-base Antenna  
Flat Diversity Antenna  
Pencil Antenna  
WT30-AT001  
WT30-AT002  
WT30-AT003  
57.5  
Three, 3 dia.  
26  
57.5 52  
75  
115  
10.5 dia.  
2010  
10.5 dia.  
2010  
35.8 dia.  
39  
DIN Rail Mounting  
Bracket  
WT30-FT001  
WT30-FT002  
Surface Mounting  
Bracket  
WT30-FT003  
Flat Diversity Antenna Mounting  
Brackets (with magnets)  
WT30-FT011  
FA Wireless SS Terminals WT30  
7
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
Cat. No. N139-E1-01  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
Industrial Devices and Components Division H.Q.  
Wireless Components Department  
Shiokoji Horikawa, Shimogyo-ku,  
Kyoto, 600-8530 Japan  
Tel: (81)75-344-7116/Fax: (81)75-344-7189  
Printed in Japan  
0105  
厂商 型号 描述 页数 下载

OMRON

XW2B 简化了连接器和接线盒的更换,并且需要更少的面板布线。[ Simplifies Connector and terminal block replacement, and requires less in-panel wiring. ] 10 页

OMRON

XW2B-1 [ ACCY EXPANSION UNIT FOR XW2B ] 11 页

OMRON

XW2B-20G4 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5-D 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20J6-1B 多应用控制器:从高性能计算机C ONTROL高度可靠的过程控制[ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-3B 简化电机控制和欧姆龙位置控制PLC模块之间的接线[ Simplify Wiring between Motor Controls and Omrons Position Control PLC Modules ] 12 页

OMRON

XW2B-20J6-6 [ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-8A 自2001年以来, CJ1M系列PLC是在全球范围内广泛应用的控制。[ Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. ] 29 页

OMRON

XW2B-20X5 [ INTERFACE MOD RCPT 34POS ] 11 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.153460s