60W Single Output Moistureproof Adaptor
OWA-60U series
SPECIFICATION
MODEL
OWA-60U-12 OWA-60U-15 OWA-60U-20 OWA-60U-24 OWA-60U-30 OWA-60U-36 OWA-60U-42 OWA-60U-48 OWA-60U-54
DC VOLTAGE
12V
15V
20V
24V
30V
36V
42V
48V
54V
18 ~ 36V
1.67A
21 ~ 42V
1.5A
6 ~ 12V
5A
7.5 ~ 15V 10 ~ 20V
12 ~ 24V
2.5A
15 ~ 30V
2A
24 ~ 48V
1.25A
60W
27 ~ 54V
1.12A
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
4A
3A
60W
60W
60W
60W
60W
60.12W
63W
60.48W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p
OUTPUT VOLTAGE TOLERANCE Note.3
LINE REGULATION
4.0%
1.0%
1.5%
4.0%
1.0%
1.0%
4.0%
1.0%
1.0%
3.0%
1.0%
1.0%
3.0%
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
SETUP, RISE TIME Note.4 500ms, 80ms/230VAC 1000ms, 80ms/115VAC at 95% load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
10ms at full load 115VAC / 230VAC
90 ~ 264VAC
47 ~ 63Hz
87%
127 ~ 370VDC
FREQUENCY RANGE
EFFICIENCY
(Typ.)
88%
89%
88%
89%
88.5%
90%
88.5%
90%
88.5%
90%
88.5%
90%
88.5%
91%
89%
115VAC
230VAC
88%
91%
INPUT
AC CURRENT (Typ.)
1.2A / 115VAC
0.7A / 230VAC
COLD START 35A(twidth=750 s measured at 50% Ipeak) at 115VAC
μ
INRUSH CURRENT (Typ.)
COLD START 65A(twidth=750 s measured at 50% Ipeak) at 230VAC
μ
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.25mA / 240VAC
95 ~ 108%
OVER CURRENT
SHORT CIRCUIT
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
14 ~ 16V
17.5 ~ 23V 23 ~ 27V
28 ~ 34V
34 ~ 40V
41 ~ 50V
46 ~ 54V
53 ~ 62V
58 ~ 66V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-35 ~ +70℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80℃, 10 ~ 95% RH
ENVIRONMENT
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL8750 listed; CSA C22.2 No.250.13-12(except for 42V,48V,54V); IP67 approved for power body
I/P-O/P:3.75KVAC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to FCC Part15
MTBF
292.8K hrs min. MIL-HDBK-217F (25℃)
130*53*35mm
OTHERS DIMENSION
PACKING
0.41Kg; 16pcs/6.8Kg/0.85CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel
capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:OWA-60U-SPEC 2015-05-28