90W Single Output Moistureproof Adaptor
OWA-90E series
SPECIFICATION
MODEL
OWA-90E-12 OWA-90E-15 OWA-90E-20 OWA-90E-24 OWA-90E-30 OWA-90E-36 OWA-90E-42 OWA-90E-48 OWA-90E-54
DC VOLTAGE
12V
15V
6A
20V
24V
30V
3A
36V
42V
48V
54V
RATED CURRENT
RATED POWER
7.5A
90W
4.5A
90W
3.75A
90W
2.5A
90W
2.15A
90.3W
1.88A
90.24W
1.67A
90.18W
90W
90W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 250mVp-p 250mVp-p 350mVp-p
OUTPUT VOLTAGE TOLERANCE Note.3
LINE REGULATION
4.0%
0.5%
1.5%
4.0%
0.5%
1.0%
4.0%
0.5%
0.5%
3.0%
0.5%
0.5%
3.0%
0.5%
0.5%
2.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME Note.4 500ms, 80ms at 95% load 115VAC / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms at full load 115VAC / 230VAC
90 ~ 264VAC
47 ~ 63Hz
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.98/115VAC, PF>0.96/230VAC at full load
89%
90%
90%
90%
90%
91%
91%
91%
91%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
0.95A / 115VAC
0.5A / 230VAC
COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC
μ
<0.25mA / 240VAC
105 ~ 115%
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
15 ~ 17V
17.5 ~ 21V 23 ~ 27V
28 ~ 34V
34 ~ 40V
41 ~ 46V
46 ~ 54V
54 ~ 60V
59 ~ 66V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80℃, 10 ~ 95% RH
ENVIRONMENT
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EN61558-1,-2-16 listed; EN60335-1 listed(except for OWA-90E-42,48,54); IP67 approved
I/P-O/P:3.75KVAC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 (CISPR22) Class B, EN55014-1, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN55014-2, light industry level (surge L- N : 2KV), criteria A
EMC IMMUNITY
MTBF
292.8K hrs min. MIL-HDBK-217F (25℃)
171*63*37.5mm
OTHERS DIMENSION
PACKING
0.92Kg; 16pcs/15.7Kg/1.01CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel
capacitor.
NOTE
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:OWA-90E-SPEC 2015-01-27