Calibration
Safety Information
The Constant Monitors are calibrated to standards
traceable to NIST. Frequency of recalibratrion should
be based on the critical nature of those ESD sensitive
items handled and the risk of failure for the ESD
protective equipment and materials. In general, we
recommend that calibration be performed annually.
Read, understand, and follow all safety information
contained in these instructions prior to the use of
Constant Monitors WSMONITOR1, WSMONITOR 2,
and WSMONITOR3. Retain these instructions for future
reference.
Warning
Use the SCS TMTOOL Verification Tester to perform
periodic testing (once every 6-12 months) of the
Constant Monitors. The Verification Tester can be
used on the shop floor within a few minutes virtually
eliminating downtime, verifying that the monitor is
operating within tolerances.
To reduce the risks associated with fire and explosion:
•
Do not use in an explosive environment - monitor is
not designed to be intrinsically safe.
To reduce the risks associated with medical device
malfunction:
•
Persons with heart pacemaker devices should never
use this monitor.
To reduce the risks associated with hazardous voltage
and fire:
•
Use only the power supply provided by SCS and
specified for the country of use.
•
Do not position the monitor accessories or other
equipment where unplugging the power supply is
difficult.
•
•
Always locate the power source (socket or outlet)
near the equipment. The power supply plug serves
as the disconnect device.
Do not modify or attempt to service the power
supply or monitor; there are no user serviceable
parts.
•
•
Do not use the power supply if damaged;
Replace power supply if damaged using only SCS
supplied parts.
Figure 7. SCS TMTOOL Verification Tester
•
Do not use the Constant Monitors WSMONITOR1,
WSMONITOR 2, WSMONITOR3 or their power
supplies outdoors in wet/humid environments.
Do not use the Constant Monitors WSMONITOR1,
WSMONITOR 2, WSMONITOR3 or their power
supplies outside of the operating conditions listed in
this user guide.
Specifications
Monitor Type
Circuitry
Impedence - single-wire
Solid-state, surface mount
Audible and visible (LED)
8 megohms
•
Alarm
Alarm Threshold
Power
•
Always follow instructions for installation as stated in
this user guide.
120VAC, 230VAC
Adjustments
Calibration
None required
Caution
To reduce the risks associated with environmental
contamination:
See SCS TMTOOL
•
Dispose of this monitor in accordance with all
applicable local and government regulations.
Item
Dimensions
Weight
WSMONITOR1 0.9" H x 1.8" W x 1.3" D
WSMONITOR2 1.0" H x 2.4" W x 2.3" D
WSMONITOR3 1.0" H x 4.0" W x 2.4" D
1.2 oz.
1.6 oz.
2.6 oz.
Notice
To reduce the risk of ESD damage to components or
assemblies being handled:
•
•
•
Monitor must be checked periodically to verify each
test mode is functioning correctly.
Ensure proper operation of monitor by performing
operational verification test as required.
Ensure tester is properly grounded.
SCS - 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: StaticControl.com
© 2015 DESCO INDUSTRIES, INC.
Employee Owned
TB-9036 Page 3 of 4