XW2R-E34GD-T

型号:

XW2R-E34GD-T

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

10 页

PDF大小:

3339 K

XConWnecto2r-TeRrminal Block Conversion Units for General-purpose Devices  
CSM_XW2R_DS_E_2_2  
Many Variations in Connectors and  
Number of Poles  
• Models available with Phillips screw, slotted screw, push-in, or  
e-CON connections.  
• The terminal arrangement enables smoother wiring work.  
• Push-in terminals simplify wiring and make the Terminal Blocks  
even easier to use. (In comparison to the OMRON XW2F.)  
• Mounting to DIN Track is possible.  
Model List  
With power supply terminals  
X W 2R -  
G
- COM  
Power supply terminals  
Wiring method  
e-CON  
I/O Points  
08  
Mounted Connector type  
Mounting method  
DIN Track  
mounting  
N
G
MIL (XG4A)  
COM  
Provided  
D
V
Vertical screw  
mounting  
Horizontal screw  
mounting  
Blank  
Without power supply terminals  
X W 2R -  
- T  
Plug/Socket  
Blank Plug (male)  
Socket (female) ∗  
Mounting method  
Wiring method  
Phillips screw  
Number of poles  
Mounted Connector type  
DIN Track  
D
J
E
P
G
F
MIL (XG4A)  
FCN  
20  
34  
40  
50  
60  
mounting  
Slotted screw (rise up)  
Push-in spring  
R
Vertical screw  
mounting  
V
D
R
M
D-sub ∗  
MR ∗  
Horizontal screw  
mounting  
Blank  
MDR ∗  
Consult your OMRON representative for these models.  
Options (Order Separately)  
Models that are mounted with screws are also available.  
Refer to the XW2R-series Connector-Terminal Block Conversion Units Catalog (Cat. No. G077) for details.  
Connecting Cables for Connector-Terminal Block Conversion Units  
Refer to the XW2Z datasheet.  
1
XW2R  
With power supply terminals  
e-CON Type  
Ordering Information  
Appearance  
I/O Points  
I/O  
Model ∗  
Mounted Connector model  
Cable Connector model  
XG4A-1431 (MIL Connector)  
XG4M-1430-T (MIL Connector)  
8 Points  
Input  
XW2R-N08GD-COM  
XN2D-4471 (e-CON Connector) XN2A-1470 (e-CON Connector)  
* Only DIN Track mounting models are described here. Refer to the XW2R-series Connector-Terminal Block Conversion Units Catalog (Cat. No.  
G077) for information on screw mounting models.  
Ratings and Specifications  
Wiring Diagram  
Power supply terminal block: 2 A,  
MIL Connector  
Connectors/e-CON Connectors: 1 A  
(However, rated current of e-CON Connector  
depends on the wires that are used.)  
Rated current  
Rated voltage  
24VDC  
Insuration resistance  
Dielectric strength  
100MΩ min. (at 500VDC)  
500VAC for 1 min (leakage current: 1 mA max.)  
External  
power  
Ambient operating  
temperature  
supply  
0 to 55°C  
AWG 24 to 14 (ferrules),  
Applicable AWG 28 to 14 (stranded wires),  
wire sizesAWG 28 to 16 (solid wires)  
Applicable  
wires  
(Outer diameter of insulation must be 4 mm max)  
AWG28-16: 8 to 10 mm  
AWG14: 9 to 10 mm  
e-CON  
Stripped  
length  
* This is the applicable range for the power supply terminal block. For the  
applicable wire sizes for I/O Connectors (e-CON), refer to page 3.  
Dimensions  
(Unit: mm)  
Power supply  
terminal block  
MIL Plug:  
XG4A-1431  
64.4  
(44.8)  
19.7  
(30.8)  
e-CON Sockets:  
XN2D-4471 x 2 sockets  
(33.1)  
2
XW2R  
Input Device Connectors: XN2 e-CON Connectors  
Ordering Information  
For Sensor  
Relay Connector  
Appearance  
Number of  
poles  
Number of  
poles  
Model  
Appearance  
Model  
4
XN2B-1470  
4
XN2A-1470  
Ratings and Specifications  
3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires),  
1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires)  
Rated current  
Rated voltage  
32 VDC  
Contact resistance  
Insuration resistance  
Dielectric strength  
Insertion durability  
30 mΩ max. (at 20 mV, 100 mA max.)  
103 MΩ min. (at 500VDC)  
1,000 VAC for 60 sec (leakage current: 1 mA max.)  
50 times  
Ambient operating  
temperature  
-30 to 75°C ∗  
Stranded wire 0.08mm2 (AWG28) to 0.5mm2 (AWG20)  
(Outer diameter of insulation must be 1.5 mm max)  
Applicable wires  
* The operating temperature range is restricted by the maximum operating temperature of the cable.  
Wiring Procedure  
3. Insert a flat-blade screwdriver  
into the release hole and  
gently reset the lever. You  
should hear the operation  
lever reset.  
Wire Preparation  
Operation lever  
(white)  
Release hole  
Use the strip gauge on the  
front panel and strip 7 to 8 mm  
of the insulation. If you use  
stranded wires, twist them  
several times.  
7 to 8 mm  
Connection Procedure  
1. Press a flat-blade  
screwdriver into the  
operation hole until  
the operation lever  
locks into place.  
Flat-blade  
screwdriver  
4. Finally, check the following items.  
Make sure the operation lever has been  
reset.  
Check the items given in step 2 again.  
(Pull lightly on the wire to see if it is held  
firmly in place.)  
Operation hole  
2. Insert the wire all the way into the wire insertion hole. Confirm that  
the insulation on the wire also enters the wire insertion hole and  
that the end of the wire has passed through the connection  
section.  
Wire insertion  
hole  
Connection  
section  
Wire insulation  
Disconnection Procedure  
1. Press in the operation level, confirm  
that the operation lever is locked into  
place, and then pull out the wire.  
Operation  
lever  
(white)  
2. After you remove the wire, always  
reset the operation lever. However, if  
you are going to connect another wire  
to the same terminal, you do not need  
to reset the operation lever and can  
immediately connect the other wire.  
3
XW2R  
Without power supply terminals  
Phillips screw  
Çl  
Ordering Information  
Appearance 1  
Mounted Connector model  
XG4A-2031  
Number of poles  
Model 2  
Dimension A (mm)  
20  
34  
40  
50  
60  
40  
XW2R-J20GD-T  
XW2R-J34GD-T  
XW2R-J40GD-T  
XW2R-J50GD-T  
XW2R-J60GD-T  
XW2R-J40FD-T  
81.7  
130.7  
151.7  
186.7  
221.7  
151.7  
XG4A-3431  
MIL Connector  
XG4A-4031  
XG4A-5031  
XG4A-6031  
FCN Connector  
FCN-364P040-AU  
*1 The mounted Connector shown in the appearance illustration is a MIL Connector.  
*2 Only DIN Track mounting models are described here. Refer to the XW2R-series Connector-Terminal Block Conversion Units Catalog (Cat. No.  
G077) for information on screw mounting models.  
Ratings and Specifications  
Details on Crimp Terminals  
Wiring Terminal Blocks  
Using Crimp Terminals (With a Terminal  
Block with M3 Screws)  
Round crimp terminals  
3.2 mm dia.  
Rated current  
1 A  
5.8 mm max.  
Rated voltage  
125 VAC, 24 VDC  
100MΩ min.(at 500VDC)  
Terminal Screw Tightening Torque  
Insuration resistance  
Forked crimp terminals  
5.8 mm max.  
Use a tightening torque of 0.5 N·m when  
connecting wires or crimp terminals to  
the terminal block.  
500VAC for 1 min  
(leakage current: 1 mA max.)  
3.2 mm  
Dielectric strength  
Ambient operating  
temperature  
0 to 55°C  
Applicable crimp terminals  
Round crimp terminals 1.25-3  
Forked crimp terminals 1.25Y-3 AWG 22 to 16 (0.30 to 1.25 mm2)  
Applicable wires  
AWG 22 to 16 (0.30 to 1.25 mm2)  
AWG 22 to 16 (round or forked crimp  
terminals)  
AWG 26 to 16 (stranded or solid wires)  
Applicable wire  
Applic  
able  
sizes  
wires Stripped length 9 mm  
Tightening  
0.5 N·m  
Wiring Diagram  
Mounted Connector model: MIL Connector  
Dimensions  
(Unit: mm)  
Drawing is MIL Plug: XG4A-@@31  
A
(44.81)  
Connector  
Terminal Block  
M3  
3.5  
7 (Pitch)  
19.7  
The label contents depend on  
the number of poles.  
Mounted Connector model: FCN Connector  
(48.05)  
5.8  
Connector  
Terminal Block  
Label Contents  
Note: The label contents for a Terminal Block with 34 poles are shown.  
4
XW2R  
Without power supply terminals  
Slotted screw (rise up)  
Ordering Information  
Appearance 1  
Mounted Connector model  
XG4A-2031  
Number of poles  
Model 2  
Dimension A (mm)  
20  
34  
40  
50  
60  
40  
XW2R-E20GD-T  
XW2R-E34GD-T  
XW2R-E40GD-T  
XW2R-E50GD-T  
XW2R-E60GD-T  
XW2R-E40FD-T  
64.4  
98.5  
XG4A-3431  
MIL Connector  
XG4A-4031  
113.5  
138.5  
163.5  
113.5  
XG4A-5031  
XG4A-6031  
FCN Connector  
FCN-364P040-AU  
*1 The mounted Connector shown in the appearance illustration is a MIL Connector.  
*2 Only DIN Track mounting models are described here. Refer to the XW2R-series Connector-Terminal Block Conversion Units Catalog (Cat. No.  
G077) for information on screw mounting models.  
Ratings and Specifications  
Details on Crimp Terminals  
Applicable crimp  
Round rod  
Applicable wires  
Rated current  
1 A  
terminals  
Dia.  
TC-05  
Dia. = 1  
AWG22 to AWG18  
(0.30 to 0.75 mm2)  
Rated voltage  
125 VAC, 24 VDC  
100MΩ min. (at 500VDC)  
8-10 mm  
8-10 mm  
Rod  
Insuration resistance  
Blade  
TC-1.25S  
Dia. = 1.5  
AWG22 to AWG16  
(0.30 to 1.25 mm2)  
t = 0.75  
W
500VAC for 1 min  
(leakage current: 1 mA max.)  
Dielectric strength  
BT1.25-9-1  
BT1.25-10-1  
W = 2.2  
AWG22 to AWG16  
(0.30 to 1.25 mm2)  
Blade  
Ambient operating  
temperature  
0 to 55°C  
Note: Round rod and blade crimp terminals are made by Nichifu.  
Applicable wire  
Appli sizes  
AWG 22 to 16 (ferrules)  
AWG 26 to 16 (stranded or solid wires)  
cable  
Stripped length  
7 mm  
wires  
Tightening  
0.5 to 0.6 N·m  
Wiring Diagram  
Mounted Connector model:MIL Connector  
Dimensions  
(Unit: mm)  
Drawing is MIL Plug: XG4A-@@31  
A
(44.81)  
Connector  
Terminal Block  
19.7  
2.5  
The label contents depend on  
the number of poles.  
Mounted Connector model:FCN Connector  
5 (Pitch)  
(43)  
Connector  
⑲ ⑳  
Terminal Block  
Label Contents  
Note: The label contents for a Terminal Block with 34 poles are shown.  
5
XW2R  
Without power supply terminals  
Push-in spring  
Ordering Information  
Appearance 1  
Mounted Connector model  
XG4A-2031  
Number of poles  
Model 2  
Dimension A (mm)  
20  
34  
40  
50  
60  
40  
XW2R-P20GD-T  
XW2R-P34GD-T  
XW2R-P40GD-T  
XW2R-P50GD-T  
XW2R-P60GD-T  
XW2R-P40FD-T  
64.4  
98.5  
XG4A-3431  
MIL Connector  
XG4A-4031  
113.5  
138.5  
163.5  
113.5  
XG4A-5031  
XG4A-6031  
FCN Connector  
FCN-364P040-AU  
*1 The mounted Connector shown in the appearance illustration is a MIL Connector.  
*2 Only DIN Track mounting models are described here. Refer to the XW2R-series Connector-Terminal Block Conversion Units Catalog (Cat. No.  
G077) for information on screw mounting models.  
Ratings and Specifications  
Details on Crimp Terminals  
Applicable Ferrules  
Use ferrules of the lengths and thicknesses  
specified below.If other lengths or thicknesses  
are used, connection maynot be possible or it  
may not be possible to insert or remove the  
posts.  
Square ferrules  
B
Rated current  
1 A  
8-10 mm  
8-10 mm  
Rated voltage  
125 VAC, 24 VDC  
100MΩ min. (at 500VDC)  
A
Round ferrules  
Insuration resistance  
Dia. C  
500VAC for 1 min  
(leakage current: 1 mA max.)  
Dielectric strength  
Ferrule Dimensions  
Ambient operating  
temperature  
Dimension A  
(Width)  
0 to 55°C  
2.7 mm max.  
Thecross-sectionalarea  
after crimping must be  
4.8 mm2 or less  
Square  
ferrules  
Dimension B  
(Height)  
AWG 24 to 14 (ferrules)  
2 mm max.  
Applicable AWG 28 to 14 (stranded or solid)  
Round  
ferrules  
Dimension C  
(Diameter)  
wire sizes  
(Outer diameter of insulation must be  
4 mm max)  
2 mm dia. max. (after crimping)  
Applicable  
wires  
Refer to page 7 for information on Square/Round ferrule and use tool.  
Stripped  
length  
AWG28-16: 8 to 10 mm  
AWG14: 9 to 10 mm  
Wiring Diagram  
Mounted Connector model: MIL Connector  
Dimensions  
(Unit: mm)  
Drawing is MIL Plug: XG4A-@@31  
A
(44.81)  
Connector  
Terminal Block  
19.7  
(33.1)  
5 (Pitch)  
Mounted Connector model: FCN Connector  
The label contents depend on  
the number of poles.  
Connector  
Terminal Block  
Label Contents  
Note: The label contents for a Terminal Block with 34 poles are shown.  
6
XW2R  
Safety Precautions  
Precautions for Correct Use  
Wiring Precautions  
Do not perform wiring work, remove connectors, or connect connectors while power is being supplied.  
Electric shock or damage to the device may result.  
Double-check all wiring before turning ON the power supply.  
After wiring, route the cable so that force is not applied directly to the connections.  
Wires for Terminal Blocks  
Do not damage the cores when stripping the insulation from them.  
Always twist stranded wires together before connecting them.  
Do not presolder wires. It may not be possible to connect them or remove them.  
XW2R-P@@ type (Square/Round ferrule)  
Type of terminal  
Manufacturer  
Size  
AWG24  
Recommend ferrule  
AI0.25-8@@  
Recommend crimp tool  
AWG22  
AI0.34-8TQ  
AI0.5-10WH  
AI0.5-8WH  
AWG20  
Phoenix Contact  
CRIMFOX6  
AI0.75-10GY  
AI0.75-8GY  
AWG18  
AWG16  
AWG14  
AWG24  
AWG22  
AWG20  
AWG18  
AWG16  
AWG14  
AI1.5-10BK  
AI2.5-8BU  
H0.25/12  
H0.34/12  
H0.5/14  
Square ferrule  
Weidmuller  
Nichifu  
PZ6 roto  
H0.75/14  
H1.5/14  
H2.5/15D  
NH11  
NH32  
NH65  
AWG22-  
AWG16  
Round ferrule  
TGV TC-1.25-9T  
Note: @@ of ferrule model is for color (Ex: YE = Yellow)  
When an electric wire is connected directly (J,E,P type)  
Model  
Strip length “a”  
XW2R-J@@  
XW2R-E@@  
9 mm  
7 mm  
a
AWG28-16: 8 to 10 mm  
AWG14: 9 to 10 mm  
XW2R-P@@  
Mounting Units to and Removing Units from DIN Track  
Mounting Procedure  
Removal Procedure  
2
PPrreessss..  
1
Hooookk..  
1. Hook the Unit on the DIN Track.  
2. Press the Unit onto the DIN Track to secure it.  
1. Insert a flat-blade screwdriver into the DIN Track lock.  
2. Move the screwdriver like a lever to free the lock.  
7
XW2R  
Connecting Spring cramp Terminals  
Using Ferrules  
How to insert wire  
How to release wire  
Release hole  
Terminal holes  
The wire should be pushed into  
the terminal block till stopping.  
Insert the screwdriver into the  
release hole and pull out the ferrule.  
Using Stripped Wires  
Inserting and Removing Wires  
Insert the screwdriver into the release hole, and  
the wire should be inserted into the wire insertion  
hole, and then pull out the screwdriver.  
Inserting Wires  
Removing Wires  
1. Press the a flat-blade screwdriver diagonally into the release hole.  
1. Press the flat-blade screwdriver diagonally into the release hole.  
Press at an angle of 10° to 15°.  
Press at an angle of 10° to 15°.  
If you press in the screwdriver correctly, you will feel the spring in  
the release hole.  
If you press in the screwdriver correctly, you will feel the spring in  
the release hole.  
Flat-blade screwdriver  
Flat-blade screwdriver  
Release hole  
1
1
10 to 15˚  
10 to 15˚  
2. Leave the flat-blade screwdriver pressed into the release hole and  
insert the stranded wire or the solid wire into the terminal hole.  
Insert the stranded wire or the solid wire until the stripped portion  
is no longer visible to prevent shorting.  
2. Leave the flat-blade screwdriver pressed into the release hole and  
pull out the wire.  
2
2
Wire  
Stranded wire/Solid wire  
3. Remove the flat-blade screwdriver from the release hole.  
3. Remove the flat-blade screwdriver from the release hole.  
3
3
8
XW2R  
Precautions for Safe Use  
Do not press the flat-blade screwdriver straight into the release hole. Doing so may break the terminal block.  
When you insert a flat-blade screwdriver into a release hole, press it down with a force of 30 N max. Applying excessive force may damage the  
terminal block.  
Do not tilt or twist the flat-blade screwdriver while it is pressed into the release hole. Doing so may break the terminal block.  
Make sure that all wiring is correct.  
Do not bend the cable forcibly. Doing so may sever the cable.  
Use tool  
Select a use tool from following table.  
Model  
Use tool  
Specialized tool and dimension  
XW2R-J@@  
XW2R-E@@  
XW2R-P@@  
Phillips screwdriver  
JIS#2  
Model XW4Z-00B  
Head of screwdriver Is 0.4 x 2.5mm max.  
Flat-blade screwdriver  
Flat-blade screwdriver  
Model  
XW4Z-00B  
Bending Radius of Connecting Cables  
To prevent damaging the Connecting Cables, use the following minimum bending radii as guidelines.  
X W 2Z - @ @ @ @ @  
End of model number Minimum bending radius  
BF-L, EE-L, FF-L  
66 mm  
67.2 mm  
83 mm  
88 mm  
A
EE  
B, D, K, L, N  
For checking electrical continuity  
XW2R-E@@ type: There is no elecrical continuity in the screw, Please confirm it at hole for confirming continuity or wiring part.  
9
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2017.4  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2017 All Right Reserved.  
厂商 型号 描述 页数 下载

OMRON

XW2B 简化了连接器和接线盒的更换,并且需要更少的面板布线。[ Simplifies Connector and terminal block replacement, and requires less in-panel wiring. ] 10 页

OMRON

XW2B-1 [ ACCY EXPANSION UNIT FOR XW2B ] 11 页

OMRON

XW2B-20G4 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5-D 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20J6-1B 多应用控制器:从高性能计算机C ONTROL高度可靠的过程控制[ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-3B 简化电机控制和欧姆龙位置控制PLC模块之间的接线[ Simplify Wiring between Motor Controls and Omrons Position Control PLC Modules ] 12 页

OMRON

XW2B-20J6-6 [ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-8A 自2001年以来, CJ1M系列PLC是在全球范围内广泛应用的控制。[ Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. ] 29 页

OMRON

XW2B-20X5 [ INTERFACE MOD RCPT 34POS ] 11 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9