Switching frequency
Current consumption
Power consumption in W
Delay first up
Delay response
Delay recovery
Setting-up
<= 20 Hz
<= 35 mA (no-load)
2 W AC
< 60 ms
< 25 ms
< 25 ms
Sensitivity adjustment
500000 cycles, cos φ = 1, 60 cyc/mn at 250 V
1.97 in (50 mm)
1.97 in (50 mm)
0.71 in (18 mm)
0.42 lb(US) (0.19 kg)
Electrical durability
Depth
Height
Width
Product weight
Environment
Product certifications
CE
CSA
UL
Ambient air temperature for operation
Ambient air temperature for storage
Vibration resistance
-13...131 °F (-25...55 °C)
-40...158 °F (-40...70 °C)
7 gn, amplitude = +/- 1.5 mm (f = 10...55 Hz) conforming to IEC 60068-2-6
10 gn (duration = 11 ms) conforming to IEC 60068-2-27
IP65 double insulation conforming to IEC 60529
Shock resistance
IP degree of protection
Ordering and shipping details
Category
21571 - SENSORS, ELECTRONIC BASIC XU & XS
Discount Schedule
GTIN
DS2
003389110703849
Nbr. of units in pkg.
Package weight(Lbs)
Returnability
1
1.26
N
Country of origin
ID
Offer Sustainability
RoHS (date code: YYWW)
Compliant - since 0841 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
Product environmental profile
Product end of life instructions
California proposition 65
- - - - - - - Substance 1
Available
Available
WARNING: This product can expose you to chemicals including:
Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and
- - - - - - - Substance 2
Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other
reproductive harm.
- - - - - - - More information
For more information go to www.p65warnings.ca.gov
Contractual warranty
Warranty period
18 months
2