Date:- 19 May, 2004
Data Sheet Issue:- 1
WESTCODE
IXYS
An
Company
Prospective Data
Medium Voltage Thyristor
Types KX120V#600 to KX120V#650
(Development Type No.)
Absolute Maximum Ratings
MAXIMUM
LIMITS
VOLTAGE RATINGS
UNITS
VDRM
VDSM
VRRM
VRSM
Repetitive peak off-state voltage, (note 1)
Non-repetitive peak off-state voltage, (note 1)
Repetitive peak reverse voltage, (note 1)
Non-repetitive peak reverse voltage, (note 1)
6000-6500
6000-6500
6000-6500
6100-6600
V
V
V
V
MAXIMUM
LIMITS
OTHER RATINGS
UNITS
IT(AV)M
IT(AV)M
IT(AV)M
IT(RMS)
IT(d.c.)
ITSM
Maximum average on-state current, Tsink=55°C, (note 2)
Maximum average on-state current. Tsink=85°C, (note 2)
Maximum average on-state current. Tsink=85°C, (note 3)
Nominal RMS on-state current, Tsink=25°C, (note 2)
D.C. on-state current, Tsink=25°C, (note 4)
1566
A
A
935
533
A
3262
2684
14.3
A
A
Peak non-repetitive surge tp=10ms, Vrm=60%VRRM, (note 5)
kA
kA
A2s
A2s
ITSM2
≤
15.8
Peak non-repetitive surge tp=10ms, Vrm 10V, (note 5)
I2t
I2t capacity for fusing tp=10ms, Vrm=60%VRRM, (note 5)
1.02×106
1.25×106
75
I2t
≤
I2t capacity for fusing tp=10ms, Vrm 10V, (note 5)
continuous, 50Hz
repetitive, 50Hz, 60s
non-repetitive
(di/dt)cr Critical rate of rise of on-state current (Note 6)
150
A/µs
300
VRGM
PG(AV)
PGM
Peak reverse gate voltage
Mean forward gate power
Peak forward gate power
Operating temperature range
Storage temperature range
5
V
3
W
W
°C
°C
40
Tj op
-40 to +115
-40 to +150
Tstg
Notes:-
1) De-rating factor of 0.13% per °C is applicable for Tj below 25°C.
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 115°C Tj initial.
≤
6) VD=67% VDRM, IFG=2A, tr 0.5µs, Tcase=115°C.
Prospective Data Sheet. Types KX120V#600 to KX120V#650 Issue 1