SINGLE
300 WATT
VWS SERIES
k e y
f e a t u r e s
•
•
•
•
300W standard full brick
•
•
•
•
planar magnetics
industry standard footprint
open-frame packaging
100C baseplate operation
superior transient response
1500 VDC isolation
VWB booster modules available
The VWS family of DC to DC converters are direct replacement converters for the
industry standard full brick. Featuring a fixed frequency design, the VWS family offers
excellent transient response and predictable EMI performance. The VWS can be
combined with IPD’s VWB booster modules to provide increased power. The VWS
converters use 100% surface mount construction, use planar magnetics, are fully
compatible with production board washing processes. The VWS modules are
manufactured in IPD’s ISO9001 factory.
t e c h n i c a l
s
p e c i f i c a t i o n s
i
n p u t
e
f
f
.
v
s
l
o
a
d
- 4 8 V
voltage range
24 VDC nominal
48 VDC nominal
18 - 36 VDC
36 - 72 VDC
input reflected ripple current
-undervoltage lockout - turn on / turn off
50mA p-p
17-15 VDC /35-32VDC
o
u t p u t
setpoint accuracy
±1%
0.2% Vo
0.2% Vo
0.5 VDC
10 %
25% Io
line regulation VIN min. - VIN max., IOUT rated
load regulation IOUT min. - IOUT max., VIN nom.
remote sense headroom
minimum output current
dynamic regulation, loadstep
Pk deviation
4% Vo
settling time
500 uS
voltage trim range
±10%
current limit threshold range, %Io rated
OVP trip range
OVP type
110 - 140%
120 - 140% Vout nom.
self recovering
shutdown/hiccup
short circuit/over current protection
g
e
n
e
r
a
l
turn-on time
remote shutdown
remote shutdown reference
switching frequency
isolation
10 ms
positive logic
Vin negative
500 KHz
input - output
input - case
output - case
1500 VDC
1050 VDC
500 VDC
temperaturecoefficient
case temperature
operating range
0.03 %/°C
-40 to +100°C
-40 to +125°C
storage range
n
o
t
e
s
thermal shutdown range
vibration, 3 axes, 5 min each
MTBF† (Bellcore TR-NWT-000332)
safety
105 - 115°C
5 g, 10-55Hz
consult factory
UL 1950, CSA 22.2-950, EN60950
6.0 oz.
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load - unless
otherwise stated.
weight (approx.)
8 8 8 - I P D C O N V e r t e r
w w w . i p d c o n v e r t e r s . c o m
4
7
3
2
6
6
8
72