XW2Z-200AA

型号:

XW2Z-200AA

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

9 页

PDF大小:

1442 K

Connector-Terminal Block Conversion Unit with 8-input e-CON Terminal Block with Common  
XW2R  
CSM_XW2R-COM_DS_E_1_1  
Conversion Unit with Industrial  
Standard  
Block Connectors  
e
-CON Terminal  
• Power supply terminals provided. Connector  
terminal blocks provided for wiring.  
• I/O connectors for easier wiring.  
• Easy connections via connectors (no special  
tools required).  
• Compatible with e-CON connectors from  
other companies.  
Connection Example  
Controller  
XW2Z-ꢀꢀꢀB  
The 32 PLC inputs are separated  
into groups of 8 inputs.  
XW2R-G32G-M1-COM  
XW2Z-ꢀꢀꢀAA  
By separating the input locations, less work  
is required for changes to sensors and other  
devices.  
XW2R-N08G-COM  
(e-CON 4 pins × 8 connectors)  
XN2A-1470  
(e-CON connector, 4 pins)  
Connection to sensor  
Relay Connector  
XN2B-1470  
XN2A-1470  
(e-CON connector, 4 pins)  
(e-CON connector, 4 pins)  
1
XW2R  
Ordering Information  
Mitsubishi PLC Module model number  
Appearance  
Model  
Pins  
I/O points  
Model  
QX41, QX41-S1, QX41-S2, QX71  
QH42P (inputs), QX41Y41P (inputs)  
LX41C4  
32  
A1SX41-S1, A1SX41-S2, A1SX71  
A1SH42 (inputs), A1SH42-S1 (inputs)  
QX42, QX42-S1, QX-82, QX82-S1  
LX42C4  
40 pins × 1 connector  
14 pins × 4 connectors  
XW2R-G32G-M1-COM  
64  
A1SX42-S1, A1SX42-S2, A1SX82-S  
Ratings and Specifications  
Wiring Diagram  
Power supply terminal block: 8 A,  
Connectors: 1 A  
Rated current  
Rated voltage  
24 VDC  
External  
Insulation  
resistance  
power supply  
100 Mmin. (at 500 VDC)  
500 VAC for 1 min  
(leakage current: 1 mA max.)  
Dielectric strength  
Ambient operating  
temperature  
0 to 55°C  
Appli-  
AWG 24 to 14 (ferrules), AWG 28 to 14  
cable Applicable (twisted wires), AWG 28 to 16 (solid  
wires wire sizes* wires) (Outer diameter of insulation  
(pow-  
er  
must be 4 mm max.)  
sup-  
ply  
termi-  
nal  
Stripped  
length  
AWG28 to 16: 8 to 10 mm,  
AWG14: 9 to 10 mm  
block)  
Dimensions  
(Unit: mm)  
108  
MIL Plug:  
Terminal block  
XG4A-4031  
98.5  
(45.11)  
2
9
9
20  
XG4A-1431  
(33.4)  
2
XW2R  
Ordering Information  
NumberofPLC  
connector pins  
Mounted Connector  
model  
Appearance  
I/O points  
I/O  
Model  
Cable Connector Model  
XG4A-1431 (PLC side) XG4M-1430-T (PLC side)  
XN2D-4471 (input side) XN2A-1470 (input side)  
8
14  
Inputs XW2R-N08G-COM  
Wiring Diagram  
Ratings and Specifications  
Power supply terminal block: 2 A, Connectors  
(including e-CON Connectors): 1 A (However,  
rated current of e-CON Connector depends on  
the wires that are used.)  
Rated current  
Rated voltage  
24 VDC  
Insulation resistance  
Dielectric strength  
100 Mmin. (at 500 VDC)  
500 VAC for 1 min (leakage current: 1 mA max.)  
Ambient operating tem-  
perature  
0 to 55°C  
Applica-  
Applicable  
blewires  
wire sizes*  
(power  
AWG 24 to 14 (ferrules), AWG 28 to 14 (twisted  
wires), AWG 28 to 16 (solid wires) (Outer  
diameter of insulation must be 4 mm max.)  
(This connection diagram is for combining with CN1 on the  
XW2R-G32G-M1-COM.)  
supply  
Stripped  
terminal  
AWG28 to 16: 8 to 10 mm,  
AWG14: 9 to 10 mm  
length  
block)  
*This is the applicable range for the power supply terminal block. For the applicable wire sizes for  
I/O Connectors (e-CON), refer to information on the applied Connectors.  
Dimensions  
(Unit: mm)  
73.9  
MIL Plug:  
64.4  
XG4A-1431  
Terminal block  
(45.11)  
2
9
9
20  
e-CON Socket:  
XN2D-4471 × 2  
(31.1)  
(33.4)  
3
XW2R  
The e-CON address assignments are for combining the XW2R-G32G-M1-COM with four XW2R-N08G-COM.  
CN3  
CN4  
CN1  
CN2  
4
XW2R  
XW2Z Cables  
Ratings and Specifications  
Rated current  
1 A  
Rated voltage  
125 VAC/24 VDC  
Contact resistance  
Insulation resistance  
Dielectric strength  
20 mmax. (at 20 mV, 100 mA max.)*1  
100 Mmin. (at 500 VDC)  
500 VAC for 1 min (leakage current: 1 mA max.)*2  
Ambient operating tem-  
perature  
25 to 80°C  
*1. This is the contact resistance of the Connectors.  
*2. This is the dielectric strength of the Connectors.  
XW2Z-@@@B Connectors: One 40-pin Connector Made by Fujitsu Component, Ltd. to One 40-pin MIL  
Connector  
Wiring Diagram  
Appearance  
Model  
XW2Z-050B  
XW2Z-100B  
XW2Z-150B  
XW2Z-200B  
XW2Z-300B  
XW2Z-500B  
XW2Z-700B  
XW2Z-010B  
XW2Z-15MB  
XW2Z-20MB  
Cable length (m)  
FCN-367J040-AU/F  
(mating side)  
0.5  
1
XG4M-4030-T  
(mating side)  
Triangular mark  
1
2
1
2
2
4
1
3
1.5  
2
3
10 10  
11 11  
20 19  
22 21  
5
7
10  
15  
20  
19 19  
20 20  
38 37  
40 39  
B
A
Cable Length (m)  
L
XW2Z-@@@AA MIL Connectors: One 14-pin MIL Connector to One 14- Pin MIL Connector  
Wiring Diagram  
Appearance  
Model  
Cable length (m)  
XW2Z-050AA  
XW2Z-100AA  
XW2Z-200AA  
XW2Z-500AA  
XW2Z-010AA  
0.5  
1
2
5
10  
Cable Length (m)  
L
Note: Wire the connectors 1:1 so that the  
connector terminal numbers  
coincide.  
5
XW2R  
Input Device Connectors: XN2 e-CON Connectors  
Sensor Connector  
Appearance  
Relay Connector  
Appearance  
Pins  
Model  
Pins  
Model  
4
XN2A-1470  
4
XN2B-1470  
Ratings and Specifications  
3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires), 1 A/pin (with AWG24 wires), 0.5 A/pin (with  
AWG26 or AWG28 wires)  
Rated current  
Rated voltage  
32 VDC  
Contact resistance  
Insulation resistance  
Dielectric strength  
Insertion durability  
30 mmax. (at 20 mV, 100 mA max.)  
103 Mmin. (at 500 V DC)  
1,000 VAC for 1 min (leakage current: 1 mA max.)  
50 times  
Ambient operating tem-  
perature  
30 to 75°C*1  
Applicable wires  
0.08 to 0.5 mm2 (AWG28 to AWG20) (Outer diameter of wire must be 1.5 mm max.)*2  
*1. The operating temperature range is restricted by the maximum operating temperature of the cable.  
*2. Consult with your OMRON representative before using wires with a single wire diameter of 0.16 mm or less.  
Connection Procedure  
Preparing Wires  
3. Insert the screwdriver in the release  
Operation lever  
(white)  
Release  
opening  
Strip 7 to 8 mm of the wire insulation  
using the STRIP GAUGE on the  
Connector as a guide, and twist the  
wire strands together several times.  
opening and gently press the lever  
until it clicks back to its original  
position.  
7 to 8 mm  
Connecting Wires  
4. Confirm the following items.  
The operation level has returned to its  
original position.  
1. Insert a flat-bladed screw driver  
and press the operation lever  
inside the operation opening until  
it locks open.  
Flat-blade  
screwdriver  
That the wire and wire insulation are in  
the proper positions, as described in  
step 2. (Pull on the wire lightly to be  
sure it is connected.)  
Operation  
opening  
2. Insert the wire all the way to the back of the wire insertion  
opening. Confirm that the wire insulation has entered the  
wire insertion opening and that the end of the core has  
passed through the contact section.  
Removing Wires  
1. Insert a flat-bladed screw driver and  
press the operation lever inside the  
operation opening until it locks open  
and then pull out the wire.  
Operation lever  
(white)  
Wire insulation  
Wire insertion opening  
Contact section  
2. Always return the operation lever to its  
original position after removing a wire.  
If another wire is to be connected, however, it can be  
connected immediately without returning the operation  
lever first.  
6
XW2R  
Safety Precautions  
Precautions for Correct Use  
Wiring Precautions  
Recommended Ferrules for XW2R-P@@ Connectors  
Do not perform wiring work, remove connectors, or connect  
connectors while power is being supplied. Electric shock or  
damage to the device may result.  
Double-check all wiring before turning ON the power  
supply.  
After wiring, confirm that the cable is connected.  
After wiring, route the cable so that force is not applied  
directly to the connections.  
Recom-  
mended  
crimp tool  
Ferrule  
type  
Manufacturer  
Size  
Ferrule model  
AWG24 AI0.25-8@@  
AWG22 AI0.34-8TQ  
AI0.5-10WH  
AWG20  
AI0.5-8WH  
Phoenix Contact  
CRIMFOX6  
AI0.75-10GY  
AWG18  
AI0.75-8GY  
Insert only one wire in each wire insertion opening. It may  
not be possible to remove the wires if more than one wire is  
inserted.  
Do not apply a current higher than the rated value. Be sure  
to check the rated current, which depends on the model of  
the cable.  
AWG16 AI1.5-10BK  
AWG14 AI2.5-8BU  
AWG24 H0.25/12  
AWG22 H0.34/12  
AWG20 H0.5/14  
AWG18 H0.75/14  
AWG16 H1.5/14  
AWG14 H2.5/15D  
Square  
ferrules  
Weidmueller  
Nichifu  
PZ6 roto  
Wires for Terminal Blocks  
Do not damage the cores when stripping the insulation from  
them.  
Always twist stranded wires together before connecting  
them.  
NH11  
NH32  
NH65  
Round  
ferrules  
AWG22- TGV  
AWG16 TC-1.25-11  
Note: Note: @@ is replaced by the color code. (Example: YE = yellow)  
Connecting Spring cramp Terminals  
Using Ferrules  
Do not presolder wires. It may not be possible to connect  
them or remove them.  
Mounting to and Removing from DIN Track  
How to insert wire  
How to release wire  
Mounting Procedure  
Removal Procedure  
2
Press.  
The wire should be pushed into  
the terminal block till stopping.  
Insert the screwdriver into the  
release hole and pull out the ferrule.  
1
Hook.  
1. Hook the Unit on the DIN Track.  
1. Insert a flat-blade screwdriver into the DIN Track lock.  
2.Move the screwdriver like a lever to free the lock.  
Using Stripped Wires  
2. Press the Unit onto the DIN Track to secure it.  
Inserting and Removing Wires  
Applicable Ferrules  
Use ferrules of the lengths and thicknesses specified below.  
If other lengths or thicknesses are used, connection may  
not be possible or it may not be possible to insert or remove  
the posts.  
Ferrule Dimensions  
Dimension A  
(width)  
2.7 mm max.  
The cross-sectional area  
after crimping must be 4.8  
mm2 or less  
Square fer-  
rules  
Inserting Wires  
Dimension B  
(height)  
2 mm max.  
1) Press the a flat-blade screwdriver diagonally into the  
release hole.  
Round fer- Dimension C  
rules (diameter)  
2 mm dia. max. (after crimping)  
Round Ferrules  
Press at an angle of 10° to 15°.  
If you press in the screwdriver correctly, you will feel the  
spring in the release hole.  
Square Ferrules  
B
Diameter C  
Flat-blade screwdriver  
Release hole  
8 to 10 mm  
1
8 to 10 mm  
A
10 to  
15°  
7
XW2R  
2) Leave the flat-blade screwdriver pressed into the release  
hole and insert the twisted stranded wires or the solid wire  
into the terminal hole.  
Precautions for Safe Use  
Do not press the flat-blade screwdriver straight into the  
release hole. Doing so may break the terminal block.  
Insert the twisted wire or the solid wire until the stripped  
portion is no longer visible to prevent shorting.  
2
When you insert a flat-blade screwdriver into a release hole,  
press it down with a force of 30 N max. Applying excessive  
force may damage the terminal block.  
Twisted wire/Solid wire  
3) Remove the flat-blade screwdriver from the release hole.  
3
Do not tilt or twist the flat-blade screwdriver while it is  
pressed into the release hole. Doing so may break the  
terminal block.  
Removing Wires  
1) Press the flat-blade screwdriver diagonally into the release  
hole.  
Press at an angle of 10° to 15°.  
If you press in the screwdriver correctly, you will feel the  
spring in the release hole.  
Make sure that all wiring is correct.  
Do not bend the cable forcibly. Doing so may sever the  
cable.  
Flat-blade screwdriver  
1
Use tool  
Select a use tool from following table.  
10 to 15°  
Use tool  
Specialized tool and dimension  
Flat-blade  
Model XW4Z-00B  
screwdriver  
Head of screwdriver Is 0.4 × 2.5mm max.  
2) Leave the flat-blade screwdriver pressed into the release  
hole and pull out the wire.  
Flat-blade screwdriver  
Models  
XW4Z-00B  
2
Wire  
3) Remove the flat-blade screwdriver from the release hole.  
3
8
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2013.9  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2013 All Right Reserved.  
厂商 型号 描述 页数 下载

OMRON

XW2B 简化了连接器和接线盒的更换,并且需要更少的面板布线。[ Simplifies Connector and terminal block replacement, and requires less in-panel wiring. ] 10 页

OMRON

XW2B-1 [ ACCY EXPANSION UNIT FOR XW2B ] 11 页

OMRON

XW2B-20G4 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20G5-D 螺丝接线端子电缆[ Screw Terminal Block Cables ] 13 页

OMRON

XW2B-20J6-1B 多应用控制器:从高性能计算机C ONTROL高度可靠的过程控制[ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-3B 简化电机控制和欧姆龙位置控制PLC模块之间的接线[ Simplify Wiring between Motor Controls and Omrons Position Control PLC Modules ] 12 页

OMRON

XW2B-20J6-6 [ Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control ] 70 页

OMRON

XW2B-20J6-8A 自2001年以来, CJ1M系列PLC是在全球范围内广泛应用的控制。[ Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. ] 29 页

OMRON

XW2B-20X5 [ INTERFACE MOD RCPT 34POS ] 11 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.213537s