Heavy Duty Pressure Transducers  
32313757  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Issue D  
Datasheet  
(Shown with mating connector. See Figure 5.)  
F
• Reduced current consumption: Helps to reduce energy  
costs, and enhances product life if used in battery driven  
systems.  
• Media compatibility: Common HFC (hydrofluorocarbon)  
refrigerants such as R410A and R134A, next generation low  
global warming potential (GWP) refrigerants such as R448A  
(Solstice® N40), R32 and R1234ZE, engine oil, petroleum-  
based hydraulic fluids, DOT 3 brake fluid, and dry air. For  
ammonia and other corrosive media, see Honeywell’s SPT Series.  
DIFFERENTIATION  
DESCRIPTION  
• Optional diagnostics mode: Beneficial in applications where  
the sensor functionality and the need to know internal or  
external failure modes is critical.  
Honeywell’s PX3 Series Heavy Duty Pressure Transducers  
use piezoresistive sensing technology with ASIC (Application  
Specific Integrated Circuit) signal conditioning in a brass  
housing and Metri-Pack 150 or cable harness electrical  
connections. The PX3 Series are fully calibrated and  
temperature compensated from -40ꢁC to 125ꢁC ꢂ-40ꢁF to  
257ꢁF].  
• Great customer value: Multiple configuration possibilities  
provide flexibility of use in the application with no upfront  
NRE or tooling charges.  
• Durable: Provides the tough environmental specifications  
needed, including insulation resistance and dielectric  
strength, external freeze-thaw resistance (see Figure 2),  
and EMC performance.  
VALUE TO CUSTOMERS  
• Total Error Band (TEB) 1.0 ꢀFSS from -20ꢁC to  
85ꢁC: Provides the most comprehensive, clear and  
meaningful indication of the sensor’s true measurement  
performance over a specified temperature range; small  
error promotes system uptime and efficiency. (See Figure 1.)  
FEATURES  
• Pressure range: 1 bar to 50 bar | 15 psi to 700 psi (absolute  
and sealed gage)  
• Ratiometric output: 0.5 Vdc to 4.5 Vdc or 0.33 Vdc to 2.97 Vdc  
• Fully calibrated and temperature compensated  
• Total Error Band: 1.0 ꢀFSS from -20ꢁC to 85ꢁC ꢂ-4ꢁF to 185ꢁF]  
• External freeze/thaw resistance: 6 cycles from -30ꢁC to  
50ꢁC ꢂ-22ꢁF to 122ꢁF]  
Figure 1. TEB Definition and Temperature Performance  
All Possible Errors  
Offset  
Full Scale Span  
• Insulation resistance: >100 MOhm, 1500 Vdc (in dry, non-  
ionized air)  
Pressure Non-Linearity  
Total  
Error  
Band  
Accuracy  
BFSL  
Pressure Hysteresis  
Pressure Non-Repeatability  
Thermal Effect on Offset  
Thermal Effect on Span  
Thermal Hysteresis  
• Dielectric strength: AC1500V, 1 min. or AC1800V, 1 s (in dry, non-  
ionized air)  
• Current consumption: 3.5 mA max.  
• EMC (radiated immunity): 200 V/m per ISO 11452-2  
• Ingress protection IP67 (Metri-Pack 150), IP69K (cable harness)  
• Response time: <2 ms  
3
Total Error Band  
2
1
• RoHS, REACH, and CE compliant  
• Six industry-standard pressure port types, including a  
tube port which provides for hermetically-sealed process  
connection  
0
-1  
-2  
-3  
POTENTIAL APPLICATIONS  
• Industrial: Refrigerant pressure monitoring in HVAC/R  
systems; air compressor system pressure  
• Transportation: Air system monitoring; hydraulic oil pressure  
monitoring  
-40°C  
[-40°F]  
0°C  
[32°F]  
85°C  
[185°F]  
-20°C  
[-4°F]  
125°C  
[257°F]  
Temperature (°C [°F])  
• High insulation resistance and dielectric strength: Protect  
the user and sensor in high over-voltage situations,  
and ensures that the device is compliant with industry  
standards.  
• High EMC performance: Operates reliably in the presence  
of electro-magnetic fields, such as near wireless signals, RF  
communication, and electrical devices.  
• High external freeze/thaw resistance: Survives exposure to  
frost, commonly found in refrigeration systems. (See Figure 2.)  
The PX3 Series is not recommended for use with media  
involving water, saturated air such as steam and vapor, and  
ammonia.  
PORTFOLIO  
Honeywell’s PX3 Series joins the PX2 Series, MLH Series, and  
SPT Series heavy duty pressure transducers.  
Sensing and Internet of Things  
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Table 1. Electrical Specifications  
Characteristic  
Parameter  
Supply voltage:  
5 Vdc  
3.3 Vdc  
0.25 Vdc  
0.25 Vdc  
Over voltage and reverse voltage  
16 Vdc  
Current consumption:  
5 Vdc supply  
3.0 mA max.  
3.3 Vdc supply  
1.6 mA to 2.1 mA  
Short circuit protection  
yes  
Nominal output transfer function:  
5 Vdc supply  
3.3 Vdc supply  
0.5 Vdc to 4.5 Vdc (ratiometric to supply)  
0.33 Vdc to 2.97 Vdc (ratiometric to supply)  
Table 2. Performance Specifications (At 25°C [77°F] and under unless otherwise noted.)  
Characteristic  
Parameter  
Operating temperature range1  
Storage temperature range1  
Compensated temperature range  
-40ꢁC to 125ꢁC ꢂ-40ꢁF to 257ꢁF]  
-40ꢁC to 125ꢁC ꢂ-40ꢁF to 257ꢁF]  
-40ꢁC to 125ꢁC ꢂ-40ꢁF to 257ꢁF]  
Total Error Band2:  
-20ꢁC to 85ꢁC ꢂ-4ꢁF to 185ꢁF]  
<-20ꢁC, >85ꢁC ꢂ<-4ꢁF, >185ꢁF]  
1.0 ꢀFSS  
2.0 ꢀFSS  
Accuracy BFSL3  
Response time  
Turn on time4  
0.25 ꢀFSS  
<2 ms (10ꢀ to 90ꢀ step change in pressure)  
<7 ms  
EMC rating5:  
surge immunity (all leads)  
electrostatic discharge  
radiated immunity  
fast transient burst  
1000 V line to ground per IEC 61000-4-5  
4 kV contact, 8 kV air per IEC 61000-4-2  
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3  
1 kV per IEC 61000-4-4  
immunity to conducted disturbances 3 V per IEC 61000-4-6  
radiated emissions  
radiated immunity  
40 dB (30 MHz to 230 MHz), 47 dB (230 MHz to 1000 MHz) per CISPR 11  
200 V/m per ISO 11452-2  
Insulation resistance  
Dielectric strength  
Load resistance  
Life  
>100 MOhm, 1500 Vdc (in dry, non-ionized air)  
AC1500V, 1 min. or AC1800V, 1 s (in dry, non-ionized air)  
>5 kOhm  
greater than 10 million full scale pressure cycles over the calibrated pressure range  
1 Dependent on external and internal seal and cable jacket materials. See Table 5 and Figure 5 for temperature range details.  
2 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all  
errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect  
on span, and thermal hysteresis. See Figure 1.  
3 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25ꢁC  
ꢂ77ꢁF]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. See Figure 1.  
4 Turn on Time: Duration from power applied until first valid output.  
5 Tested using 1.5 m ꢂ59.1 in] cable.  
Table 3. Pressure Reference Definitions  
Pressure Reference Definition  
Output is calibrated to be proportional to the difference between applied pressure and a fixed reference to  
perfect vacuum (absolute zero pressure).  
Absolute  
Sensor construction is identical to the absolute version with a built in reference at zero pressure in order to  
minimize measurement error over temperature. The output is calibrated to be proportional to the difference  
between applied pressure and a reference of 1 standard atmosphere (1.013 barA | 14.7 psiA). Example: 100  
Sealed gage1  
psi sealed gage has a calibrated pressure range from 14.7 psi absolute to 114.7 psi absolute. (See Figure 3.)  
1 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.  
Sensing and Internet of Things  
2
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 3. Ratiometric Output Option AA for 100 psi,  
Absolute vs Sealed Gage  
Diagnostics Mode  
The PX3 Series diagnostics mode allows the device to  
indicate when internal or external faults occur. If an internal  
fault occurs, the output will rail to the preset lower or upper  
limit values shown in Figure 4 and Table 5.  
5
4.5  
4
External faults will result in the sensor’s output exceeding  
those preset limits (lower or upper). (For example, if the  
external sensor ground (signal) were lost, the sensor output  
would exceed the upper rail of 97.5ꢀ.)  
3.5  
3
2.5  
100 psi absolute  
100 psi sealed gage  
2
1.5  
Figure 4. Analog Output with Diagnostics  
100  
1
0.5  
0
Upper Rail (97.5%)  
90  
80  
70  
60  
0
20  
40  
60  
80  
100  
120  
114.7  
140  
14.7  
50  
40  
30  
20  
Pressure (psi Absolute)  
Table 4. Pressure Ratings  
bar  
psi  
Operating Over-  
10  
Lower Rail (2.5%)  
Operating Over-  
Pressure pressure Pressure Pressure pressure Pressure  
Burst  
Burst  
0
10 20 30 40 50 60 70 80 90 100  
Pressure (psi)  
1
1.6  
2
5
8
15  
30  
70  
150  
250  
450  
450  
450  
450  
1000  
1000  
1000  
1000  
1000  
-
115  
250  
400  
750  
750  
1150  
1150  
1500  
1500  
1500  
1500  
1500  
-
5
8
Table 5. Output Transfer Function Codes  
10  
10  
17  
31  
31  
31  
32  
69  
69  
69  
69  
69  
69  
17  
50  
Fault Condition  
Analog Diagnostic Rail  
2.5  
4
17  
100  
150  
200  
250  
300  
500  
600  
667  
700  
-
EEPROM Corrupt  
below lower rail  
27  
Sensor Bridge Open  
(any element)  
above upper rail  
above upper rail  
6
51  
8
51  
Sensor Bridge Short  
(any element)  
10  
16  
20  
25  
35  
40  
46  
50  
51  
80  
Low supply voltage  
below lower rail  
above upper rail  
103  
103  
103  
103  
103  
103  
Loss of ground connection  
-
-
-
-
-
-
Sensing and Internet of Things  
3
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Table 6. Environmental and Mechanical Specifications  
Characteristic  
Parameter  
Shock:  
threaded ports  
tube port  
100 G per MIL-STD-202G, Method 213B, Cond. F (at 25ꢁC ꢂ77ꢁF])  
100 G per MIL-STD-202F, Method 213B, and Condition C  
Vibration:  
threaded ports  
tube port  
20 G sweep, 10 Hz to 2000 Hz (at 25ꢁC ꢂ77ꢁF])  
10 Hz to 55 Hz, 2 mm displacement, tested as per IEC 60068-2-6; Test FC. (at 25ꢁC ꢂ77ꢁF])  
Ingress protection:  
Metri-Pack 150 electrical connector  
cable harness electrical connector  
IP67  
IP69K  
Ambient humidity  
0 ꢀRH to 95 ꢀRH, non-condensing  
External freeze/thaw resistance  
>6 cycles from -30ꢁC to 50ꢁC ꢂ-22ꢁF to 122ꢁF]  
Wetted materials:  
threaded ports  
brass C36000; lead (Pb) content: 3.7ꢀ max.  
tube port  
copper UNS C12200; lead (Pb) free  
braze filler  
silver and copper alloy  
internal O-ring media seal  
sensing element and substrate  
adhesives  
seal material as required by the application (see seal material media compatibility options below)  
alumina, glass, silicon  
epoxy  
Internal O-ring material media compatibility1:  
HNBR (option H)  
silicone (option S)  
refrigerants, engine oil, petroleum-based hydraulic fluid  
dry air  
Other materials:  
Metri-Pack 150 electrical connector  
external O-ring seal on G1, M1 ports  
PBT 30ꢀ GF  
nitrile (-30ꢁC to 125ꢁC ꢂ-22ꢁF to 257ꢁF])  
1 Honeywell can assist with selecting suitable O-ring seal material for the media based on the seal manufacturer’s recommendation.  
The customer should test the compatibility with the media to ensure that it is correct for the application.  
CAUTION  
PRODUCT DAMAGE TO TUBE PRESSURE PORT TYPE DURING BRAZING  
Ensure that the temperature of the brass port and plastic connector is maintained below 125ꢁC during flame brazing.  
Exposure to temperatures higher than 125ꢁC can cause permanent product damage and can compromise ingress protection  
leading to short circuits.  
Failure to comply with these instructions may result in product damage.  
CAUTION  
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES  
• Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating  
materials and thread sealants can result in significantly different torque values from one application to the next.)  
• When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling.  
Ensure the sealant is rated for the application.  
• Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.  
• Always hand-start transducers into the hole to prevent cross threading and damage.  
• Ensure that torque is not applied to the electrical connector.  
• Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged  
seals can compromise ingress protection, leading to short circuits.  
Failure to comply with these instructions may result in product damage.  
CAUTION  
PRODUCT DAMAGE DUE TO PARTICULATES  
• Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All  
PX3 Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect sensor output.  
• It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less  
likely to enter and settle within the pressure transducer if it is in this position.  
• Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output;  
rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue.  
Failure to comply with these instructions may result in product damage.  
Sensing and Internet of Things  
4
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 5. Nomenclature and Order Guide  
For example, PX3AN1BS150PAAAX defines a PX3 Series Heavy Duty Pressure Transducer, Metri-Pack 150,  
standard (UL V-0) electrical connector type, 1/4-18 NPT pressure port type, brass housing body, silicone:  
-40°C to 125°C [-40°F to 257°F] seal material and temperature range, 150 psi pressure range, absolute pressure  
reference, ratiometric: 0.5 Vdc to 4.5 Vdc output transfer function, no special  
PX3 A N1 B S 150P A AA X  
Special  
Series  
X
Heavy Duty  
Pressure Transducer1  
PX3  
Output Transfer Function  
AA Ratiometric, 5.0 V: 10% to 90% Vs  
Electrical Connector Type2  
DA Ratiometric, 5.0 V: 10% to 90% Vs (diagnostics on)6  
AC Ratiometric, 3.3 V: 10% to 90% Vs  
Metri-Pack 150,  
DC Ratiometric, 3.3 V: 10% to 90% Vs (diagnostics on)6  
A
Standard (UL V-0)3  
Pressure Reference  
PVC Cable with three  
Absolute  
22 AWG wires: 1 m [3.2 ft]4  
A
S
E
F
Sealed gage7  
-40°C to 100°C [-40°F to 212°F]  
PVC Cable with three  
Pressure Range3  
22 AWG wires: 2 m [6.6 ft]4  
-40°C to 100°C [-40°F to 212°F]  
psi  
15 psi  
30 psi  
bar  
1 bar  
1.6 bar  
2 bar  
2.5 bar  
4 bar  
6 bar  
001B  
1.6B  
002B  
2.5B  
015P  
030P  
050P  
100P  
150P  
200P  
250P  
300P  
500P  
600P  
667P  
700P  
XLPE Cable with three  
50 psi  
22 AWG wires: 1 m [3.2 ft]4  
-40°C to 125°C [-40°F to 257°F]  
M
N
100 psi  
150 psi  
200 psi  
250 psi  
300 psi  
500 psi  
600 psi  
667 psi  
700 psi  
004B  
006B  
008B  
010B  
016B  
020B  
025B  
035B  
040B  
046B  
050B  
XLPE Cable with three  
8 bar  
22 AWG wires: 2 m [6.6 ft]4  
-40°C to 125°C [-40°F to 257°F]  
10 bar  
16 bar  
20 bar  
25 bar  
35 bar  
40 bar  
46 bar  
50 bar  
Pressure Port Type5  
7/16-20 UNF  
1/4 inch 45° Flare  
Female Schrader  
(SAE J512)  
F1  
Internal O-ring Material and Temperature Range2,8  
G1/4 A-G  
(ISO 1179-3)  
HNBR (Hydrogenated Nitrile Butadiene Rubber):  
-30°C to 125°C [-22°F to 257°F] (50 hr at 135°C [257°F)  
G1  
H
S
Silicone: -40°C to 125°C [-40°F to 257°F]  
M12 x 1.5  
M1  
(ISO 6149-3)  
Mating Connector3  
1/4-18 NPT  
1/8-27 NPT  
N1  
N2  
1 Not all catalog listing combinations are shown. Custom products are  
available. Please contact Honeywell.  
2 Custom configurations such as varied cable lengths, end mating connectors,  
different O-ring materials, and different pressure ranges are available.  
T1  
Tube  
3 Metri-Pack 150 mating connectors with shielded cable and three 22 AWG  
wires are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] cable  
length and part no. 3685302 for 3 m [9.8 ft] cable length.  
4 PVC Flame Retardant (FR) type cable is FT1 rated per IEC60332-1; XLPE  
non-flame retardant cable is FT2 rated per IEC60332-1.  
Housing Body Material  
B Brass (C36000)  
5 See Table 6 for pressure port materials.  
6 See page 3 for Diagnostics Mode information.  
7 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.  
8 See Table 6 for O-ring seal material media compatibility.  
Sensing and Internet of Things  
5
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 6. Metri-Pack Mounting Dimensions (For reference only. mm/[in].) E  
F1, G1, N1, N2, M1  
T1  
Pinout  
General  
product  
marking  
Pin A  
Pin A  
Pin A = Ground  
Pin B = Vsupply  
Pin C = Vout  
Yellow lettering  
22,0  
[0.87]  
Pin C  
Pin C  
Pin B  
Pin B  
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512) G1: G1/4 A-G (ISO 1179-3)  
Seal: 45ꢁ cone  
Mating geometry: SAE J512  
Installation torque: 17 N m ꢂ12.5 ft-lb]  
Seal: nitrile O-ring (included)  
Mating geometry: ISO 1179-1  
Installation torque: 50 N m ꢂ36.9 ft-lb]  
Weight: 35,1 g ꢂ1.2 oz]  
Weight: 54,5 g ꢂ1.9 oz]  
ø17,0  
[0.67]  
ø17,0  
[0.67]  
ø21,60  
37,4  
[1.47]  
[0.85]  
ø21,60  
35,9  
[1.41]  
[0.85]  
49,6  
[1.95]  
15,4  
1,85  
[47.1]  
[0.61]  
13,9  
[0.55]  
12,2  
[0.48]  
11,2  
[0.44]  
7/16-20 UNF 1/4 in 45° Flare  
Female Schrader (SAE J512)  
ø15,9  
G1/4 A-G (ISO 1179-3)  
[0.63]  
M1: M12 x 1.5 (ISO 6149-3)  
N1: 1/4-18 NPT  
Seal: Nitrile O-ring (included)  
Seal: Pipe thread  
Mating geometry: ISO 6149-1  
Installation torque: 25 N m ꢂ18.4 ft-lb]  
Mating geometry: ANSI B1.20.1  
Installation torque: Two to three turns from finger tight  
Weight: 33,9 g ꢂ1.2 oz]  
Weight: 35,1 g ꢂ1.2 oz]  
ø17,0  
[0.67]  
ø17,0  
[0.67]  
ø21,60  
ø21,60  
[0.85]  
34,9  
[1.37]  
[0.85]  
35  
[1.4]  
48,4  
[1.91]  
50  
[2.0]  
12,9  
[0.51]  
13  
[0.5]  
13,9  
[0.53]  
15,0  
[0.59]  
M12 x 1.5 (ISO 6149-3)  
1/4-18 NPT  
N2: 1/8-27 NPT  
T1: Tube  
ø17,0  
[0.67]  
Seal: Pipe thread  
Seal: Brazing  
Mating geometry: ANSI B1.20.1  
Weight: 32 g ꢂ1.1 oz]  
Installation torque: Two to three turns from finger tight  
Weight: 31,2 g ꢂ1.1 oz]  
39,5  
[1.56]  
ø17,0  
[0.67]  
96,5  
[3.80]  
ø21,60  
ø23,0  
[0.85]  
36  
[1.4]  
[0.91]  
Ensure this area is  
protected during the  
brazing process so  
that temperatures  
do not exceed  
57,0  
[2.24]  
46  
[1.8]  
14  
[0.5]  
125°C [257°F].  
7,0  
[0.27]  
10,0  
[0.39]  
1/8-27 NPT  
ø7,3  
[0.29]  
ø6,35  
[0.25]  
Sensing and Internet of Things  
6
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 7. Cable Harness Mounting Dimensions Shown by Pressure Port Type (For reference only. mm/[in].) E  
F1, G1, N1, N2, M1  
T1  
Wire  
colors  
General  
product  
marking  
Black = Ground  
Red = Vsupply  
White = Vout  
White label with  
black lettering  
22,0  
[0.87]  
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512) G1: G1/4 A-G (ISO 1179-3)  
Seal: 45ꢁ cone  
Seal: nitrile O-ring (included)  
Mating geometry: ISO 1179-1  
Installation torque:  
Mating geometry: SAE J512  
Installation torque:  
17 N m ꢂ12.5 ft-lb]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
50 N m ꢂ36.9 ft-lb]  
Weight: 90 g ꢂ3.2 oz]  
Weight: 70 g ꢂ2.5 oz]  
ø
21,6  
[0.85]  
ø21,6  
[0.85]  
33,1  
[1.30]  
31,6  
[1.24]  
45,3  
[1.78]  
15,4  
[0.61]  
42,75  
[1.683]  
13,9  
[0.55]  
7/16-20 UNF 1/4 in 45° Flare  
Female Schrader (SAE J512)  
12,2  
[0.48]  
11,2  
[0.44]  
G1/4 A-G (ISO 1179-3)  
ø
15,9  
[0.63]  
M1: M12 x 1.5 (ISO 6149-3)  
N1: 1/4-18 NPT  
Seal: nitrile O-ring (included)  
Mating geometry:  
ISO 6149-1  
Seal: Pipe thread  
Mating geometry:  
ANSI B1.20.1  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
Installation torque:  
25 N m ꢂ18.4 ft-lb]  
Weight: 69 g ꢂ2.4 oz]]  
Installation torque:  
Two to three turns  
from finger tight  
Weight: 70 g ꢂ2.5 oz]  
ø21,6  
[0.85]  
ø21,6  
30,6  
[1.20]  
[0.85]  
30,6  
[1.20]  
45,6  
[1.79]  
12,9  
[0.51]  
44,1  
12,9  
[1.73] [0.51]  
15,0  
[0.59]  
13,5  
[0.53]  
1/4-18 NPT  
M12 x 1.5 (ISO 6149-3)  
N2: 1/8-27 NPT  
T1: Tube  
Seal: Pipe thread  
Mating geometry:  
ANSI B1.20.1  
Installation torque:  
Two to three turns  
from finger tight  
Weight: 66 g ꢂ2.3 oz]  
Seal: Brazing  
Weight: 67 g ꢂ2.4 oz]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
ø23,0  
[0.91]  
32,2  
[1.38]  
ø21,6  
[0.85]  
31,6  
[1.24]  
92,2  
[3.63]  
41,6  
[1.64]  
13,9  
Ensure this area is  
[0.55]  
protected during the  
brazing process so that  
temperatures do not  
exceed 125°C [257°F].  
57,0  
[2.24]  
10,0  
[0.39]  
7,0  
[0.27]  
1/8-27 NPT  
ø7,3  
[0.29]  
ø6,35  
[0.25]  
Sensing and Internet of Things  
7
ADDITIONAL INFORMATION  
The following associated literature is available on the  
Honeywell web site at sensing.honeywell.com:  
WARNING  
PERSONAL INJURY  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
• Product line guide  
• Product range guide  
• Product installation instructions  
• Application notes:  
Failure to comply with these instructions could result in  
death or serious injury.  
- Heavy Duty Pressure Transducers, PX2 Series and PX3  
Series  
WARNING  
- PX2 Series and PX3 Series Heavy Duty Pressure  
Transducers for Potential Use in Industrial Refrigeration  
MISUSE OF DOCUMENTATION  
The information presented in this datasheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
- PX2 Series and PX3 Series Heavy Duty Pressure  
Transducers for Potential Use in Industrial HVAC/R  
Applications  
• Technical notes:  
- Total Error Band Specification for Honeywell Heavy  
Duty Pressure Transducers, PX2 Series and PX3 Series  
Failure to comply with these instructions could result in  
death or serious injury.  
- Media Compatibility for Honeywell Heavy Duty  
Pressure Transducers, PX2 Series and PX3 Series  
• CAD models  
Warranty/Remedy  
Honeywell warrants goods of its manufacture as being free  
of defective materials and faulty workmanship during the  
applicable warranty period. Honeywell’s standard product  
warranty applies unless agreed to otherwise by Honeywell  
in writing; please refer to your order acknowledgement or  
consult your local sales office for specific warranty details.  
If warranted goods are returned to Honeywell during the  
period of coverage, Honeywell will repair or replace, at its  
option, without charge those items that Honeywell, in its sole  
discretion, finds defective. The foregoing is buyer’s sole  
remedy and is in lieu of all other warranties, expressed or  
implied, including those of merchantability and fitness for  
a particular purpose. In no event shall Honeywell be liable  
for consequential, special, or indirect damages.  
Find out more  
Honeywell serves its customers through  
a worldwide network of sales offices and  
distributors. For application assistance,  
current specifications, pricing or name  
of the nearest Authorized Distributor,  
contact your local sales office.  
While Honeywell may provide application assistance  
personally, through our literature and the Honeywell web site, it  
is buyer’s sole responsibility to determine the suitability of the  
product in the application.  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this writing.  
However, Honeywell assumes no responsibility for its use.  
To learn more about Honeywell’s  
sensing and switching products, call  
+1.815.235.6847 or 1.800.537.6945,  
visit sensing.honeywell.com, or e-mail  
inquiries to info.sc@honeywell.com  
Honeywell Safety and Internet of Things  
9680 Old Bailes Road  
32313757-D-EN | D | 06/17  
© 2017 Honeywell International Inc.  
Solstice® N40 is a registered trademark of Honeywell International Inc.  
Fort Mill, SC 29707  
www.honeywell.com  
厂商 型号 描述 页数 下载

SEMIKRON

PX308 散热器对于所有隔离式电源模块[ Heatsink For all isolated power modules ] 2 页

SEMIKRON

PX308/300F 散热器对于所有隔离式电源模块[ Heatsink For all isolated power modules ] 2 页

ETC

PX314ZG/100 VERGUSSMASSEN EPOXY SW 100G\n[ VERGUSSMASSEN EPOXY SW 100G ] 6 页

ETC

PX314ZG/1000 VERGUSSMASSEN EPOXY 1000G[ VERGUSSMASSEN EPOXY 1000G ] 5 页

ETC

PX314ZG/250 VERGUSSMASSEN EPOXY 250G\n[ VERGUSSMASSEN EPOXY 250G ] 6 页

ETC

PX314ZG/50 VERGUSSMASSEN EPOXY SW 50G\n[ VERGUSSMASSEN EPOXY SW 50G ] 6 页

ETC

PX314ZG/500 VERGUSSMASSEN EPOXY SW 500G\n[ VERGUSSMASSEN EPOXY SW 500G ] 6 页

INTERSIL

PX3511A 与保护功能先进的同步整流降压MOSFET驱动器[ Advanced Synchronous Rectified Buck MOSFET Drivers with Protection Features ] 10 页

INTERSIL

PX3511ADAG 与保护功能先进的同步整流降压MOSFET驱动器[ Advanced Synchronous Rectified Buck MOSFET Drivers with Protection Features ] 10 页

INTERSIL

PX3511ADAG-R3 与保护功能先进的同步整流降压MOSFET驱动器[ Advanced Synchronous Rectified Buck MOSFET Drivers with Protection Features ] 10 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.194903s