CUI Inc │ SERIES: VUF-S400-XXR │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 2 of 5
INPUT
parameter
voltage
conditions/description
min
90
typ
max
264
63
units
Vac
Hz
frequency
current
47
at 90 Vac, full load
6.35
35
A
inrush current
at 230 Vac, full load, cold start
A
Built-in ac fuse. A blown fuse usually indicates permanent
damage to the power supply serviceable by factory only.
input fuse
power factor correction
meets EN 61000-3-2 Class D
OUTPUT
parameter
conditions/description
min
typ
max
units
total regulation
±1
%
output voltage returns to within 1% in less than 2.5 ms, 50%
load change, peak transient does not exceed 5%.
transient response
overshoot
turn-on and turn-off overshoot shall not exceed 5% over
nominal voltage.
turn-on delay
hold-up time
120 Vac
1
s
at 80% load
20
ms
%
adjustment range
output user adjustable
±5
designated as RS+ and RS- on CN3, total voltage
compensation for cable losses with respect to the main output.
remote sense1
remote on/off
defined RSW on CN3, requiring a low signal to inhibit output.
green - the power supply is operating normally.
orange - when any protection occurs or RSW is low.
LED display (LED 1)
designated as PG on CN3. This signal goes high 100~500 ms
after the output reaches regulation. It goes low at least 1 ms
before loss of regulation.
power good
designated as CSH on CN3, optional single wired for forced
surrent sharing function and parallel up to 4 units within 10%
accuracy at full load.
current sharing
current monitor
AC fail (optional)
designated as CMN on CN3 for for current sense for 0.5~3 Vdc
to represent 0~100% output current.
designated as ACF on CN3 to monitor the input voltage when
input goes under 80 ±5 Vac the signal will go low (0 V) and
then go high (+5 V) once it reappears over 86 Vac.
Notes:
1. Not available for current sharing models
PROTECTIONS
parameter
conditions/description
min
typ
max
units
power supply shuts down when ac input is under 80 ±5 Vac.
When ac line reappears over 86 ±5 Vac, the power supply
restarts automatically.
input under voltage protection
over voltage protection
over current protection
short circuit protection
over temperature protection
shutdown and latches, ac input reset required to restart
130
140
%
auto recovery
110
85
%Io
auto recovery upon removal of short
shutdown, auto recovery
°C