ISOLATED DC/DC CONVERTERS
18 Vdc - 60 Vdc Input 12 Vdc /16 A Output
Nov. 17, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Absolute Maximum Ratings
Unit
V
Parameter
Min
-0.3
-
Typ
Max
60
Notes
Continuous Input Voltage
Input Transient Voltage
Remote On/Off
-
-
-
-
-
-
Non-operating
100 mS maximum
100
18
V
-0.3
-
V
I/O Isolation Voltage
Ambient Temperature
Storage Temperature
1500
85
V
-40
-55
°C
°C
125
Note: Ratings used beyond the maximum ratings may cause a reliability degradation of the converter or may
permanently damage the device.
Input Specifications
Parameter
Min
Typ
Max
Unit
Notes
Operating Input Voltage
18
48
60
V
Input Current (full load)
Input Current (no load)
Remote Off Input Current
-
-
-
-
200
5
12
240
10
A
mA
mA
Input Reflected Ripple Current
(rms)
With simulated source impedance of
10uH, 5Hz to 20MHz. Use a
100uF/100V electrolytic capacitor with
ESR=1 ohm max, at 200KHz@25°C.
-
-
5
10
40
mA
Input Reflected Ripple Current
(pk-pk)
30
mA
I2t Inrush Current Transient
Turn-on Voltage Threshold
Turn-off Voltage Threshold
-
0.05
16.8
15.8
0.1
A2s
V
16
15
17.5
16.5
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
Recommend a fast-acting fuse with maximum rating of 20A on system board. Refer to the fuse
manufacture’s datasheet for further information.
Notes: 1. This converter has internal C-L-C (1uF-0.2uH-1uF-2.2uF*5) filter.
2. All specifications are typical at 25 °C unless otherwise stated.
Output Specifications
Parameter
Min
Typ
Max
Unit
Notes
Output Voltage Set Point
11.92
12
12.08
V
Vin=48V, Io=50% load
Load Regulation
Line Regulation
-
-
±20
±10
±50
±20
mV
mV
Regulation Over Temperature
(-40deg.C-85deg.C)
-
±100
±200
mV
Vin=48V, Full load, 0-20MHz BW, with a
1µF ceramic capacitor and a 10uF
Tantalum cap at output.
Ripple and Noise (pk-pk)
Ripple and Noise (rms)
-
-
100
25
150
40
mV
mV
Ripple and Noise (pk-pk)
under worst case
Over all operating input voltage, load
and ambient temperature condition
-
-
-
200
16
mV
A
Output Current Range
0
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
2