MY4ZIN1-D2

型号:

MY4ZIN1-D2

描述:

通用和功能填充小型功率继电器的顺序控制和功率开关应用[ Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications ]

品牌:

OMRON[ OMRON ELECTRONICS LLC ]

页数:

18 页

PDF大小:

446 K

General-purpose Relay  
MY New model  
Versatile and Function-filled Miniature Power  
Relay for Sequence Control and Power  
Switching Applications  
• Models with lockable test buttons now available.  
• Many variations possible through a selection of operation indi-  
cators (mechanical and LED indicators), lockable test button,  
built-in diode and CR (surge suppression), bifurcated contacts,  
etc.  
• Arc barrier standard on 4-pole Relays.  
• Dielectric strength: 2,000 VAC (coil to contact)  
• Environment-friendly cadmium-free contacts.  
• Safety standard approvals obtained.  
LR  
• Wide range of Sockets (PY, PYF Series) and optional parts are  
available.  
• Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A  
• Provided with nameplate.  
Ordering Information  
Relays  
Standard Coil Polarity  
Type  
Contact form  
Plug-in socket/Solder terminals  
Without LED indicator  
Standard with LED indicator  
With LED indicator and  
lockable test button  
Standard  
DPDT  
4PDT  
MY2N  
MY2IN  
MY2  
MY4N  
MY4IN  
MY4  
MY4Z  
---  
4PDT (bifurcated)  
DPDT  
MY4ZN  
MY4ZIN  
With built-in diode  
(DC only)  
MY2N-D2  
MY4N-D2  
MY4ZN-D2  
MY2N-CR  
MY4N-CR  
MY4ZN-CR  
MY2IN-D2  
MY4IN-D2  
MY4ZIN-D2  
MY2IN-CR  
MY4IN-CR  
MY4ZIN-CR  
4PDT  
---  
4PDT (bifurcated)  
DPDT  
---  
With built-in CR  
(220/240 VAC, 110/120 VAC  
only)  
---  
4PDT  
---  
4PDT (bifurcated)  
---  
Reverse Coil Polarity  
Type  
Contact form  
Plug-in socket/Solder terminals  
With LED indicator With LED indicator and  
lockable test button  
Standard (DC only)  
DPDT  
MY2N1  
MY2IN1  
MY4IN1  
MY4ZIN1  
4PDT  
MY4N1  
4PDT (bifurcated)  
DPDT  
MY4ZN1  
With built-in diode  
(DC only)  
MY2N1-D2  
MY4N1-D2  
MY4ZN1-D2  
MY2IN1-D2  
MY4IN1-D2  
MY4ZIN1-D2  
4PDT  
4PDT (bifurcated)  
Note: When ordering, add the rated coil voltage and “(s)” to the model number. Rated coil voltages are given in the coil ratings table.  
Example: MY2 6VAC (S)  
New model  
Rated coil voltage  
General-purpose Relay MY New model  
1
Accessories (Order Separately)  
Sockets  
Poles  
Front-mounting  
Socket (DIN-track/  
screw mounting)  
Back-mounting Socket  
Wire-wrap terminals  
Without clip With clip  
Solder terminals  
Without clip With clip  
PCB terminals  
PY08-02  
2
4
PYF08A-E  
PYF08A-N  
PY08  
PY08-Y1  
PY08QN  
PY08QN-Y1  
PY08QN2  
PY08QN2-Y1  
PYF14A-E  
PYF14A-N  
PY14  
PY14-Y1  
PY14QN  
PY14QN2  
PY14QN-Y1  
PY14QN2-Y1  
PY14-02  
Socket Hold-down Clip Pairing  
Relay type  
Poles  
Front-connecting Socket (DIN-track/  
screw mounting)  
Back-connecting Socket  
Solder/Wire-wrap terminals  
Socket Clip  
PY08(QN)  
PCB terminals  
Socket  
Clip  
PYC-A1  
Socket  
Clip  
Without 2-pole test  
button  
2
4
2
PYF08A-E  
PYF08A-N  
PYC-P  
PY08-02  
PY14-02  
PY08-02  
PYC-P  
PYC-P2  
PYC-P2  
PYF14A-E  
PYF14A-N  
PY14(QN)  
PY08(QN)  
2-pole test button  
PYF08A-E  
PYF08A-N  
PYC-E1  
PYC-P2  
PYC-P2  
Mounting Plates for Sockets  
Socket model  
For 1 Socket  
For 18 Sockets  
For 36 Sockets  
PY08, PY08QN(2), PY14, PY14QN(2)  
PYP-1  
PYP-18  
PYP-36  
Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets.  
Track and Accessories  
Supporting Track (length = 500 mm)  
Supporting Track (length = 1,000 mm)  
End Plate  
PFP-50N  
PFP-100N, PFP-100N2  
PFP-M  
Spacer  
PFP-S  
Specifications  
Coil Ratings  
Rated voltage  
Rated current  
Coil  
resistance  
Coil inductance  
(reference value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
Power  
voltage consumption  
(approx.)  
50 Hz  
214.1 mA  
60 Hz  
Arm. OFF  
Arm. ON  
% of rated voltage  
80% max. 30% min. 110%  
AC  
6 V*  
183 mA  
12.2  
46 Ω  
0.04 H  
0.17 H  
0.69 H  
3.22 H  
0.08 H  
0.33 H  
1.30 H  
5.66 H  
1.0 to 1.2 VA  
(60 Hz)  
12 V  
106.5 mA  
53.8 mA  
91 mA  
46 mA  
24 V  
180 Ω  
788 Ω  
48/50 V*  
24.7/  
25.7 mA  
21.1/  
22.0 mA  
110/120 V  
220/240 V  
9.9/10.8 mA  
4.8/5.3 mA  
8.4/9.2 mA  
4.2/4.6 mA  
4,430 Ω  
19.20 H  
83.50 H  
32.1 H  
0.9 to 1.1 VA  
(60 Hz)  
18,790 Ω  
136.4 H  
DC  
6 V*  
151 mA  
75 mA  
39.8 Ω  
160 Ω  
0.17 H  
0.73 H  
3.20 H  
10.60 H  
45.60 H  
0.33 H  
1.37 H  
5.72 H  
21.0 H  
86.2 H  
10% min.  
0.9 W  
12 V  
24 V  
37.7 mA  
18.8 mA  
9.0/9.9 mA  
636 Ω  
48 V*  
100/110 V  
2,560 Ω  
11,100 Ω  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and  
15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C.  
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).  
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-  
sistor if required.  
5. Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative.  
2
General-purpose Relay MY New model  
Contact Ratings  
Item  
2-pole  
4-pole  
4-pole (bifurcated)  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4, L/R = 7 ms)  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4, L/R = 7 ms)  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4, L/R = 7 ms)  
Rated load  
5A, 250 VAC  
5A, 30 VDC  
2A, 250 VAC  
2 A, 30 VDC  
3 A, 250 VAC  
3 A, 30 VDC  
0.8 A, 250 VAC  
1.5 A, 30 VDC  
3 A, 250 VAC  
3 A, 30 VDC  
0.8 A, 250 VAC  
1.5 A, 30 VDC  
Carry current  
10 A (see note)  
5 A (see note)  
Max. switching  
voltage  
250 VAC  
125 VDC  
250 VAC  
125 VDC  
Max. switching  
current  
10 A  
5 A  
Max. switching  
power  
2,500 VA  
300 W  
1,250 VA  
300 W  
1,250 VA  
150 W  
500 VA  
150 W  
1,250 VA  
150 W  
500 VA  
150 W  
Failure rate  
(reference value)  
5 VDC, 1 mA  
1 VDC, 1 mA  
1 VDC, 100 µA  
Note: Don’t exceed the carry current of a Socket in use. Please see page 9.  
Characteristics  
Item  
All Relays  
Contact resistance  
Operate time  
100 mmax.  
20 ms max.  
Release time  
20 ms max.  
Max. operating frequency  
Mechanical: 18,000 operations/hr  
Electrical:  
1,800 operations/hr (under rated load)  
Insulation resistance  
Dielectric strength  
Vibration resistance  
1,000 Mmin. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)  
Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Destruction: 1,000 m/s2  
Malfunction: 200 m/s2  
Shock resistance  
Endurance  
See the following table.  
Operating: –55°C to 70°C (with no icing)  
Operating: 5% to 85%  
Ambient temperature  
Ambient humidity  
Weight  
Approx. 35 g  
Note: The values given above are initial values.  
Endurance Characteristics  
Pole  
Mechanical life (at 18,000 operations/hr)  
Electrical life  
(at 1,800 operations/hr under rated load)  
2-pole  
4-pole  
AC:50,000,000 operations min.  
DC:100,000,000 operations min.  
500,000 operations min.  
200,000 operations min.  
100,000 operations min.  
4-pole (bifurcated)  
20,000,000 operations min.  
General-purpose Relay MY New model  
3
Approved Standards  
VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
10 x 103  
2
4
6, 12, 24, 48/50, 100/110  
110/120, 200/220,  
220/240 VAC  
6, 12, 24, 48, 100/110,  
125 VDC  
10 A, 250 VAC (cosφ=1)  
10 A, 30 VDC (L/R=0 ms)  
100 x 103  
5 A, 250 VAC (cosφ=1)  
5 A, 30 VDC (L/R=0 ms)  
MY4Z AC; 50 x 103  
UL508 Recognitions (File No. 41515)  
No. of poles  
Coil ratings  
6 to 240 VAC  
6 to 125 VDC  
Contact ratings  
Operations  
6 x 103  
2
4
10 A, 30 VDC (General purpose)  
10 A, 250 VAC (General purpose)  
5 A, 250 VAC (General purpose)  
5 A, 30 VDC (General purpose)  
CSA C22.2 No. 14 Listings (File No. LR31928)  
No. of poles  
Coil ratings  
6 to 240 VAC  
6 to 125 VDC  
Contact ratings  
Operations  
6 x 103  
2
4
10 A, 30 VDC  
10 A, 250 VAC  
5 A, 250 VAC (Same polarity)  
5 A, 30 VDC (Same polarity)  
IMQ (File No. EN013 to 016)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
10 x 103  
2
4
6, 12, 24, 48/50, 100/110  
110/120, 200/220,  
220/240 VAC  
6, 12, 24, 48, 100/110,  
125 VDC  
10 A, 30 VDC  
10 A, 250 VAC  
100 x 103  
5 A, 250 VAC  
5 A, 30 VDC  
MY4Z AC; 50 x 103  
LR Recognitions (File No. 98/10014)  
No. of poles  
Coil ratings  
6 to 240 VAC  
6 to 125 VDC  
Contact ratings  
Operations  
50 x 103  
2
10 A, 250 VAC (Resistive)  
2 A, 250 VAC (PF0.4)  
10 A, 30 VDC (Resistive)  
2 A, 30 VDC (L/R=7 ms)  
50 x 103  
4
5 A, 250 VAC (Resistive)  
0.8 A, 250 VAC (PF0.4)  
5 A, 30 VDC (Resistive)  
1.5 A, 30 VDC (L/R=7 ms)  
SEV Listings (File No. 99.5 50902.01)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
10 x 103  
2
4
6 to 240 VAC  
6 to 125 VDC  
10 A, 250 VAC  
10 A, 30 VDC  
100 x 103  
5 A, 250 VAC  
5 A, 30 VDC  
MY4Z AC; 50 x 103  
4
General-purpose Relay MY New model  
Engineering Data  
Maximum Switching Power  
MY2  
MY4, MY4Z  
AC resistive load  
AC inductive load  
(cosφ=0.4)  
AC resistive load  
AC inductive load  
(cosφ=0.4)  
DC resistive load  
DC resistive load  
DC inductive load  
(L/R=7 ms)  
DC inductive load  
(L/R=7 ms)  
Switching voltage (V)  
Switching voltage (V)  
Endurance  
MY2 (Resistive Loads)  
MY2 (Inductive Loads)  
10000  
5000  
10000  
5000  
3000  
3000  
250 VAC  
250 VAC  
1000  
1000  
500  
30 VDC  
30 VDC  
500  
300  
30 VDC  
30 VDC  
300  
250 VAC  
250 VAC  
100  
100  
50  
30  
50  
30  
10  
10  
Switching current (A)  
MY4 (Resistive Loads)  
Switching current (A)  
MY4 (Inductive Loads)  
10000  
5000  
10000  
5000  
3000  
3000  
250 VAC  
30 VDC  
1000  
1000  
30 VDC  
500  
300  
500  
300  
30 VDC  
30 VDC  
250 VAC  
100  
100  
250 VAC  
250 VAC  
50  
30  
50  
30  
10  
10  
Switching current (A)  
Switching current (A)  
General-purpose Relay MY New model  
5
MY4Z (Resistive Loads)  
MY4Z (Inductive Loads)  
10000  
10000  
5000  
3000  
5000  
3000  
1000  
1000  
250 VAC  
30 VDC  
500  
300  
500  
300  
30 VDC  
30 VDC  
100  
100  
250 VAC  
30 VDC  
50  
30  
50  
30  
250 VAC  
250 VAC  
10  
10  
Switching Current (A)  
Switching Current (A)  
6
General-purpose Relay MY New model  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
2-Pole Models  
MY2N  
2.6  
Eight, 1.2 dia. × 2.2 long holes  
0.5  
28 max.  
6.4  
36 max.  
21.5 max.  
4-Pole Models  
MY4N  
2.6  
Eight, 1.2 dia. × 2.2 long holes  
0.5  
28 max.  
36 max.  
6.4  
21.5 max.  
Models with Test Button  
MY2IN  
2.6  
Eight, 1.2 dia. × 2.2 long holes  
8
28 max.  
36 max.  
14.2  
21.5 max.  
MY4IN  
2.6  
Fourteen, 1.2 dia. × 2.2 long holes  
8
28 max.  
14.2  
36 max.  
<1.417>  
6.4  
21.5 max.  
General-purpose Relay MY New model  
7
Terminal Arrangement/Internal Connections (Bottom View)  
MY2  
MY2N/MY2IN  
(AC Models)  
MY2N/MY2IN  
(DC Models)  
MY2N-D2/MY2IN-D2  
(DC Models Only)  
1
5
4
8
1
5
4
8
1
5
4
8
1
5
4
8
9
12  
14  
9
12  
14  
9
12  
14  
9
12  
14  
+
+
13  
+
13  
13  
13  
MY2N-CR/MY2IN-CR  
(AC Models Only)  
MY2N1/MY2IN1  
(DC Models Only)  
MY2N1-D2/MY2IN1-D2  
(DC Models Only)  
1
5
4
8
1
5
4
8
1
5
4
8
9
12  
14  
9
12  
14  
9
12  
14  
+
+
13  
13  
13  
MY4(Z)  
MY4(Z)N/MY4(Z)IN  
(AC Models)  
MY4(Z)N/MY4(Z)IN  
(DC Models)  
MY4(Z)N-D/MY4(Z)IN-D2  
(DC Models Only)  
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
9
10 11 12  
14  
9
10 11 12  
14  
+
14  
13  
13  
13  
14  
13  
MY4(Z)N-CR/MY4(Z)IN-CR  
(AC Models Only)  
MY4(Z)N1/MY4(Z)IN1  
(DC Models Only)  
MY4(Z)N1-D2/MY4(Z)IN1-D2  
(DC Models Only)  
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
9
10 11 12  
14  
+
+
14  
13  
13  
14  
13  
Note: The DC models have polarity.  
8
General-purpose Relay MY New model  
Socket for MY  
Track-mounted (DIN Track) Socket  
Conforms to VDE 0106, Part 100  
• Snap into position along continuous sections of any mount-  
ing track.  
• Facilitates sheet metal design by standardized mounting di-  
mensions.  
• Design with sufficient dielectric separation between termi-  
nals eliminates the need of any insulating sheet.  
Safety Standards for Sockets  
Model  
Standards  
File No.  
PYF08A-E, PYF08A-N  
UL508  
E87929  
PYF14A-E, PYF14A-N  
CSA22.2  
LR31928  
Back-connecting Sockets  
Specifications  
Item  
Pole  
Model  
Carry current  
10 A  
Dielectric withstand  
voltage  
Insulation resistance  
(see note 2)  
Screwless Clamp  
Terminal Socket  
2
4
2
PYF08S  
PYF14S  
2,000 VAC, 1 min  
Less than 1,000 MΩ  
5 A  
Track-mounted  
Socket  
PYF08A-E  
7 A  
2,000 VAC, 1 min  
1,000 Mmin.  
100 Mmin.  
PYF08A-N (see note 3)  
PYF14A-E  
7 A (see note 4)  
4
2
5 A  
PYF14A-N (see note 3)  
PY08(-Y1)  
5 A (see note 4)  
7 A  
Back-connecting  
Socket  
1,500 VAC, 1 min  
PY08QN(-Y1)  
PY08-02  
4
PY14(-Y1)  
3 A  
PY14QN(-Y1)  
PY14-02  
Note: 1. The values given above are initial values.  
2. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength.  
3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55°C.  
4. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40°C, reduce the current to 60%.  
5. The MY2(S) can be used at 70°C with a carry current of 7 A.  
General-purpose Relay MY New model  
9
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Socket  
Dimensions  
Terminal arrangement/  
Internal connections  
(top view)  
Mounting holes  
38.2 max.  
36.5 max.  
PYF08S  
23.2 max.  
---  
85 max.  
(5.3)  
Two, M3, M4, or 4.5-dia. holes  
PYF08A-E  
Two, 4.2 x 5  
mounting  
holes  
Eight, M3 x 8  
sems screws  
72 max.  
(TOP VIEW)  
23 max.  
Note: Track mounting is also  
possible. Refer to page  
31 max.  
12 for supporting tracks.  
22 max.  
PYF08A-N  
42  
4
12  
1
4
1
12  
42  
14  
5
44  
8
8
5
3.0 dia.  
14  
44  
3.5 dia. or M3  
18.7  
67 max.  
73  
PYF-08A-N  
41  
12  
11  
9
12  
41  
14  
9
11  
Note: Track mounting is also  
possible. Refer to page  
A2  
A2  
14  
A1  
13  
14 13  
14  
12 for supporting tracks.  
A2 A2 A1  
30 max.  
10  
General-purpose Relay MY New model  
Socket  
Dimensions  
Terminal arrangement/  
Internal connections  
(top view)  
Mounting holes  
36.5 max.  
PYF14S  
31 max.  
---  
85 max.  
Two, 4.2 x 5  
mounting  
holes  
PYF14A-E  
Two, M3, M4, or 4.5-dia. holes  
Fourteen, M3 x 8  
sems screws  
72 max.  
(TOP VIEW)  
Note: Track mounting is also  
possible. Refer to page  
29.5 max.  
12 for supporting tracks.  
31 max.  
42 32 22 12  
PYF14A-N  
4
3
2
1
Two, 4.5 dia. or M4  
4
44  
8
3
2
1
42  
32  
22  
12  
34 24 14  
7
6
5
8
7
24  
14  
44  
34  
6
5
67 max.  
PYF-14A-N  
26  
21  
11  
9
41  
12  
31  
73  
10  
11  
A2  
14  
A2  
14  
A1  
13  
12 11 10  
9
Note: Track mounting is also  
possible. Refer to page  
41 31 21 11  
14 14  
A2 A2  
13  
A1  
12 for supporting tracks.  
30 max.  
29.5 max.  
General-purpose Relay MY New model  
11  
Socket  
Dimensions  
Terminal arrangement/  
Internal connections  
(bottom view)  
Mounting holes  
PY08/PY08-Y1  
(See note)  
Eight, 3 x 1.2 elliptical holes  
25.5 max.  
29.5 max.  
20 max.  
24 max.  
42 max.  
Note: The PY08-Y1 includes sections indicated by  
dotted lines.  
PY08QN/  
PY08QN-Y1  
(See note)  
29.5 max.  
22 max.  
41.5 max.  
24 max.  
42 max.  
Note: The PY08QN-Y1 includes sections  
indicated by dotted lines.  
PY08-02  
25.5 max.  
29.5 max.  
22 max.  
Eight, 1.3-dia.  
holes  
16.5 max.  
(See note)  
Fourteen, 3 x 1.2 elliptical holes  
PY14/PY14-Y1  
25.5 max.  
29.5 max.  
24 max.  
20 max.  
42 max.  
Note: The PY14-Y1 includes sections indicated by  
dotted lines.  
PY14QN/  
PY14QN-Y1  
(See note)  
29.5 max.  
41.5 max.  
42 max.  
22 max.  
24 max.  
Note: The PY14QN-Y1 includes sections  
indicated by dotted lines.  
PY14-02  
25.5 max.  
29.5 max.  
22 max.  
Fourteen, 1.3-dia.  
holes  
16.5 max.  
Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.  
12  
General-purpose Relay MY New model  
Hold-down Clips  
PYC-A1  
(2 pcs per set)  
PYC-E1  
(2 pcs per set)  
36.3  
36.3  
4.25  
5.75  
4.5  
0.1  
1.2  
4.5  
4.5  
PYC-P  
PYC-P2  
5
10  
29 max.  
28  
3.3  
38.5  
Mounting Plates for Back-connecting Sockets  
PYP-36  
PYP-1  
Two, 3.4-dia. holes  
72 elliptical holes  
t=1.6  
PYP-18  
72 elliptical holes  
General-purpose Relay MY New model  
13  
Tracks and Accessories  
Supporting Tracks  
PFP-50N/PFP-100N  
7.3 0.15  
4.5  
35 0.3  
27 0.15  
1
15 (5)  
25  
15  
25  
25  
25  
10  
10  
1000 (500) *  
Note: The figure in the parentheses is for PFP-50N.  
PFP-100N2  
16  
4.5  
29.2  
35 0.3  
27 24  
1
1.5  
25  
15  
15  
25  
25  
25  
10  
10  
1000  
End Plate  
PFP-M  
10  
6.2  
1
M4 x 8 pan head screw  
1.8  
35.3  
35.5  
50  
11.5  
1.8  
1.3  
4.8  
10  
M4 spring washer  
Spacer  
PFP-S  
16  
12  
5
34.8  
44.3  
16.5  
14  
General-purpose Relay MY New model  
Precautions  
Refer to General Precautions on page 11 of the General-purpose Relays and Power Relays Group Catalog (X034).  
Connections  
Do not reverse polarity when connecting DC-operated Relays with  
built-in diodes or indicators or high-sensitivity DC-operated Relays.  
Mounting  
Whenever possible, mount Relays so that it is not subject to vibra-  
tion or shock in the same direction as that of contact movement.  
General-purpose Relay MY New model  
15  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
Cat. No. J111-E1-03  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON RELAY & DEVICES Corporation  
General Purpose Relay Division  
Marketing & Product Engineering Department  
1110 Sugi, Yamaga-City,  
Kumamoto, 861-0596 Japan  
Tel: (81)968-44-4160/Fax: (81)968-44-4107  
Printed in Japan  
16  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if  
specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL  
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR  
STRICT LIABILITY.  
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the product.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government regulations.  
• Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix  
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased product.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
ERRORS AND OMISSIONS  
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent  
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
COPYRIGHT AND COPY PERMISSION  
This catalog shall not be copied for sales or promotions without permission.  
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this  
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.  
Cat. No. J111-E1-03  
2007.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2007 All Rights Reserved.  
Mouser Electronics  
Authorized Distributor  
Click to View Pricing, Inventory, Delivery & Lifecycle Information:  
Omron:  
MY3-AC110/120(S) MY4N-AC110/120S MY2E-02-AC110/120 MY2-DC100/110(S) MY4N-D2-DC24S MY4-DC6  
MY2K-US-AC120 MY4N-AC24(S) MY4E-02-AC24 MY4-DC12(S) MY4Z-DC24(S) MY4-AC24(S) MY4N-  
DC100/110S PTF08A-E MY2-DC12(S) MY3N-AC110/120 PT08-0 MY2N-AC220/240(S) MY2N-AC110/120(S)  
MY4ZN-AC110/120(S) MY2N-DC12(S) PTF14A-E MY2-AC110/120(S) MY2-AC24(S) MY4-AC110/120(S) MY4IN-  
AC24(S) MY4-DC24(S) MY2-DC24(S) MY2-02-AC24 MY2N-DC24(S) MY4N-DC24(S) MY2N-D2-DC24S MY2N-  
DC24 MY4N-DC24 MY2N-D2-DC24 MY4N-D2-DC24 MY2N-AC24(S) MY3-02-AC110/120 MY3-AC24 MY3  
AC110/120 MY2-02-DC24 MY4N AC220/240 (S) MY2K AC120 MY4H-US DC24 MY4IN AC220/240 (S) MY2IN  
AC110/120 (S) MY3 DC24 MY4IN AC110/120 (S) MY2IN AC24 (S) MY2IN DC24 (S) MY2 AC220/240 (S) MY4IN  
DC12 (S) MY2K-US DC24 MY4-02 DC24 MY4 DC100/110 (S) MY2 DC48 (S) MY4-02-AC110-120 MY4-AC220-  
240S MY4IN-DC24(S) MY4N-DC12(S) MY2N-D2-DC12(S) MY4-02-DC12 PY14QN PY14QN2 MY3-DC100/110  
MY2-02-AC100/110 MY2-02-AC110/120 MY2-02-AC220/240 MY2-02-DC100/110 MY2-02-DC12 MY2-02-DC48  
MY2-02-DC6 MY2-02-US-SV AC220/240 MY2F-AC110/120 MY2F-AC220/240 MY2F-AC24 MY2F-DC12 MY2F-  
DC24 MY2F-V0-AC110/120 MY2IN1-D2 DC100/110 (S) MY2IN1-D2 DC12 (S) MY2IN1-D2 DC24 (S) MY2IN-CR  
AC110/120 (S) MY2IN-CR AC220/240 (S) MY2IN-D2 DC100/110 (S) MY2IN-D2 DC12 (S) MY2IN-D2 DC24 (S)  
MY2K-02-DC24 MY2K-US-AC24 MY2K-US-DC12 MY2K-US-DC48 MY2N1-D2 DC100/110 (S) MY2N1-D2 DC12 (S)  
MY2N1-D2 DC24 (S) MY2N-CR AC110/120 (S) MY2N-CR AC220/240 (S) MY2N-D2 DC100/110 (S) MY3-02-  
AC220/240 MY3-02-AC24 MY3-02-DC100/110  
厂商 型号 描述 页数 下载

OMRON

MY4 通用继电器[ General-purpose Relay ] 20 页

OMRON

MY4 AC12 (S) [ RELAY GEN PURPOSE 4PDT 3A 12V ] 35 页

OMRON

MY4 AC24 (S) [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

OMRON

MY4 AC6 (S) [ RELAY GENERAL PURPOSE 4PDT 3A 6V ] 35 页

OMRON

MY4 DC12 (S) [ RELAY GEN PURPOSE 4PDT 3A 12V ] 35 页

OMRON

MY4 DC24 (S) [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

OMRON

MY4 DC6 (S) [ RELAY GENERAL PURPOSE 4PDT 3A 6V ] 35 页

OMRON

MY4-02-AC24 [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

OMRON

MY4-02-DC12 [ RELAY GEN PURPOSE 4PDT 3A 12V ] 35 页

OMRON

MY4-02-DC24 [ RELAY GEN PURPOSE 4PDT 3A 24V ] 35 页

PDF索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

IC型号索引:

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

0

1

2

3

4

5

6

7

8

9

Copyright 2024 gkzhan.com Al Rights Reserved 京ICP备06008810号-21 京

0.160082s