Input Characteristics
Parameter
Model
Min.
4.5
Typ.
5
Max.
5.5
13.2
9
Unit
5V Input Models
12V Input Models
5V Input Models
12V Input Models
Input Voltage Range
10.8
-0.7
-0.7
---
12
---
---
---
VDC
Input Surge Voltage (1 sec. max.)
29
Reverse Polarity Input Current
Input Filter
0.3
A
All Models
LC Filter
Internal Power Dissipation
---
---
650
mW
Output Characteristics
Parameter
Conditions
Min.
---
Typ.
±1.0
±0.1
±1.2
Max.
±3.0
±1.0
±1.5
Unit
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
---
%
---
%
Load Regulation
See Model Selection Guide
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
---
---
---
100
---
150
200
15
mV P-P
mV P-P
Over Line, Load & Temp.
---
mV rms
Temperature Coefficient
Short Circuit Protection
---
±0.01
±0.02
%/℃
0.5 Second Max.
Isolation and Safety Standards
Parameter
Conditions
Min.
3000
4500
10
Typ.
---
Max.
---
Unit
VACrms
VPK
I/O Isolation Voltage (rated)
60 Seconds
I/O Isolation Test Voltage
I/O Isolation Resistance
I/O Isolation Capacitance
Flash tested for 1 Second
500 VDC
---
---
---
---
GΩ
100KHz, 1V
---
15
20
pF
cUL/UL60950-1, CSA C22.2 No. 60950-1-03
UL60601-1,CSA C22.2 No.601-1
Safety Standards
Approvals
IEC/EN 60950-1, IEC/EN 60601-1
IEC60950-1 CB report, cUL/UL 60950-1 certificate
UL60601-1 UL certificate
General Characteristics
Parameter
Conditions
Min.
50
Typ.
80
Max.
100
---
Unit
KHz
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
2,000,000
---
Hours
Recommended Input Fuse
5V Input Models
12V Input Models
500mA Slow-Blow Type
200mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Conditions
Ambient
Min.
-25
---
Max.
+85
+90
+125
95
Unit
℃
℃
℃
% rel. H
Storage Temperature Range
Humidity (non condensing)
Cooling
-50
---
Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.)
---
260
℃
DS_PI01S/D_03202012
E-mail: DCDC@delta.com.tw
http://www.delta.com.tw/dcdc